Evaluation of a cyano stationary phase for the determination of tacrolimus, sirolimus and cyclosporin A in whole blood by high-performance liquid chromatography-tandem mass spectrometry

被引:11
|
作者
Hatsis, P [1 ]
Volmer, DA [1 ]
机构
[1] Natl Res Council Canada, Inst Marine Biosci, Halifax, NS B3H 3Z1, Canada
关键词
immunosuppressants; cyano column; negative ions;
D O I
10.1016/j.jchromb.2004.06.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The potential of a cyano HPLC column for the analysis of three immunosuppressants is investigated. Tacrolimus, sirolimus and cyclosporin A, were used to probe differences in the retention and efficiency of a cyano column compared to the more widely used C 18 column. The cyano column showed comparable retention for all three compounds, whereas the C 18 column showed stronger retention, especially for cyclosporin A. Furthermore, the efficiencies at 50degreesC were up to 12 times higher on the cyano column. As a result, a baseline separation was achieved in less than three minutes with the cyano column, using an isocratic mobile phase of 52/48 (v/v) acetonitrile/water at 0.45 mL/min. The analysis of immunosuppressant drugs in human whole blood was performed with the cyano column using a selected reaction monitoring (SRM) method for each analyte with negative ion mode electrospray ionization on a triple quadrupole mass spectrometer. Detection limits were 0.05 ng/mL for sirolimus, 0.1 ng/mL for cyclosporin A and 0.2 ng/mL for tacrolimus. Calibration curves were linear over three orders of magnitude. Good agreement was obtained with the actual levels of immunosuppressant drugs in patient samples with an average error of less than 10%. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 50 条
  • [1] Rapid liquid chromatography-tandem mass spectrometry routine method for simultaneous determination of sirolimus, everolimus, tacrolimus, and cyclosporin A in whole blood
    Streit, F
    Armstrong, VW
    Oellerich, M
    CLINICAL CHEMISTRY, 2002, 48 (06) : 955 - 958
  • [2] VALIDATION OF A FAST HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY ASSAY FOR THE SIMULTANEOUS MEASUREMENT OF CYCLOSPORIN A, TACROLIMUS AND RAPAMYCIN IN WHOLE BLOOD
    Kuhn, J.
    Kleesiek, K.
    Knabbe, C.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S765 - S765
  • [3] Simultaneous quantification of tacrolimus and sirolimus, in human blood, by high-performance liquid chromatography - Tandem mass spectrometry
    Taylor, PJ
    Salm, P
    Lynch, SV
    Pillans, PI
    THERAPEUTIC DRUG MONITORING, 2000, 22 (05) : 608 - 612
  • [4] Liquid chromatography-tandem mass spectrometry method for determination cyclosporine A, tacrolimus, sirolimus, everolimus and MPA in blood
    Brozmanova, H.
    Urinovska, R.
    Perinova, I
    Budakova, L.
    Grundmann, M.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 540 - 540
  • [5] Determination of 19 drugs of abuse and metabolites in whole blood by high-performance liquid chromatography-tandem mass spectrometry
    Bjork, Marie Kjaergaard
    Nielsen, Marie K. K.
    Markussen, Lotte O.
    Klinke, Helene B.
    Linnet, Kristian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (07) : 2393 - 2401
  • [6] Evaluation of IMx immunoassay of whole blood sirolimus using high-performance liquid chromatography/tandem mass spectrometry as standard
    Wang, S.
    Vicente, F. B.
    Smith, F. A.
    Peng, Y.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A77 - A77
  • [7] Ultra Fast Liquid Chromatography-Tandem Mass Spectrometry Routine Method for Simultaneous Determination of Cyclosporin A, Tacrolimus, Sirolimus, and Everolimus in Whole Blood Using Deuterated Internal Standards for Cyclosporin A and Everolimus
    Meinitzer, Andreas
    Gartner, Gabriele
    Pilz, Stefan
    Stettin, Mariana
    THERAPEUTIC DRUG MONITORING, 2010, 32 (01) : 61 - 66
  • [8] Measurement of sirolimus in whole blood by high-performance liquid chromatography/mass spectrometry
    Gubanich, K.
    Gatautis, V.
    Van Lente, F.
    Wang, S.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A89 - A89
  • [9] Determination of Immunosuppressive Pharmaceuticals in Whole Blood Following Kidney Transplantation by High-performance Liquid Chromatography-Tandem Mass Spectrometry
    Mislanova, Csilla
    Pribojova, Jana
    Valachovicova, Martina
    Zilinska, Zuzana
    ANALYTICAL LETTERS, 2017, 50 (15) : 2359 - 2368
  • [10] On-line solid-phase extraction high-performance liquid chromatography-tandem mass spectrometry for the quantitative analysis of tacrolimus in whole blood hemolyzate
    Volker Neu
    Nathanaël Delmotte
    Uwe Kobold
    Thomas Dülffer
    Rupert Herrmann
    Herbert von der Eltz
    Christian G. Huber
    Analytical and Bioanalytical Chemistry, 2012, 404 : 863 - 874