A Sensor-Type PC Strand with an Embedded FBG Sensor for Monitoring Prestress Forces

被引:56
|
作者
Kim, Sung Tae [1 ]
Park, YoungHwan [1 ]
Park, Sung Yong [1 ]
Cho, Keunhee [1 ]
Cho, Jeong-Rae [1 ]
机构
[1] Korea Inst Construct & Bldg Technol, Div Struct Engn Res, Goyang Si 411712, Gyeonggi Do, South Korea
来源
SENSORS | 2015年 / 15卷 / 01期
关键词
PSC; strand; optical fiber sensor; FBG;
D O I
10.3390/s150101060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Prestressed Concrete Wire and Strand (PC) strands are the most used materials to introduce prestress in a Pre-Stressed Concrete (PSC) structure. However, it is difficult to evaluate the final prestress force of the PC strand after prestressing or its residual prestress force after completion of the structure on site. This impossibility to assess eventual loss of prestress of the PC strand has resulted in a number of serious accidents and even in the collapse of several structures. This situation stresses the necessity to maintain the prestress force residual or after prestressing for the evaluation of the health of the concrete structure throughout its lifespan. Recently, several researchers have studied methods enabling one to verify the prestress force by inserting an optical fiber sensor inside the strand but failed to provide simple techniques for the fabrication of these devices to fulfill measurement performance from the design prestress to failure. Moreover, these methods require the additional installation of electrical resistance strain gages, displacement sensors and load cells on the outer surface of the structure for long-term precise measurement. This paper proposes a method enabling one to evaluate precisely and effectively the prestress force of the PC strand and intends to verify the applicability of the proposed method on actual concrete structures. To that end, an innovative PC strand is developed by embedding a Fiber Bragg Grating (FBG) sensor in the core wire of the PC strand so as to enable short term as well as long term monitoring. The measurement performance of the developed strand is then evaluated experimentally and the reliability of the monitoring data is assessed.
引用
收藏
页码:1060 / 1070
页数:11
相关论文
共 50 条
  • [1] Sensor-type methods for ammonia monitoring
    Dzerzhinskij Filial, Nizhegorodskijo GTU, Dzerzhinsk, Nizhegorodskaya oblast, Russia
    Defektoskopiya, 2003, (10): : 78 - 96
  • [2] Embedded FBG-Based Sensor for Joint Movement Monitoring
    Li, Linqing
    He, Runjie
    Soares, Maria Simone
    Savovic, Svetislav
    Hu, Xuehao
    Marques, Carlos
    Min, Rui
    Li, Xiaoli
    IEEE SENSORS JOURNAL, 2021, 21 (23) : 26793 - 26798
  • [3] Analysis of Long-Term Prestress Loss in Prestressed Concrete (PC) Structures Using Fiber Bragg Grating (FBG) Sensor-Embedded PC Strands
    Kim, Sung-Tae
    Park, Young-Soo
    Yoo, Chul-Hwan
    Shin, Soobong
    Park, Young-Hwan
    APPLIED SCIENCES-BASEL, 2021, 11 (24):
  • [4] Design of Embedded FBG Sensor System for Ultralight Aircraft Wing Monitoring
    Dvorak, Milan
    Ruzicka, Milan
    Kabrt, Miroslav
    STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 1665 - 1672
  • [5] Multiple sensor-type system for monitoring the microbicidal effectiveness of aseptic sterilisation processes
    Reisert, S.
    Geissler, H.
    Weiler, C.
    Wagner, P.
    Schoening, M. J.
    FOOD CONTROL, 2015, 47 : 615 - 622
  • [6] Monitoring of prestress and bond stress of self-sensing FBG steel strand
    Zhu, Wanxu
    Shen, Quanxi
    Qin, Heying
    MEASUREMENT, 2021, 177
  • [7] Structural health monitoring for smart composites using embedded FBG sensor technology
    Lau, K. -T.
    MATERIALS SCIENCE AND TECHNOLOGY, 2014, 30 (13A) : 1642 - 1654
  • [8] An embedded FBG strain sensor used in the dry-type air-core reactor health monitoring
    Zhou, Yan-Hui
    Zhao, Zhen-Gang
    Li, Ying-Na
    Zhang, Chang-Sheng
    Xie, Tao
    Cui, Zhi-Gang
    Wang, Ke
    Tan, Xiang-Yu
    Li, Chuan
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2015, 26 (03): : 422 - 426
  • [9] Structural Health Monitoring using an Embedded PZT-FBG Ultrasonic Sensor Array
    Botsev, Y.
    Arad, E.
    Tur, M.
    Kressel, I.
    Ben-Simon, U.
    Gail, S.
    Osmont, D.
    PROCEEDINGS OF THE FOURTH EUROPEAN WORKSHOP ON STRUCTURAL HEALTH MONITORING 2008, 2008, : 649 - 656
  • [10] A study of distributed embedded thermal monitoring in electric coils based on FBG sensor multiplexing
    Mohammed, Anees
    Djurovic, Sinisa
    MICROPROCESSORS AND MICROSYSTEMS, 2018, 62 : 102 - 109