A new detector system for low energy X-ray fluorescence coupled with soft X-ray microscopy: First tests and characterization

被引:13
|
作者
Gianoncelli, Alessandra [1 ]
Bufon, Jernej [1 ,2 ,3 ]
Ahangarianabhari, Mandi [4 ,5 ]
Altissimo, Matteo [1 ]
Bellutti, Pierluigi [6 ]
Bertuccio, Giuseppe [4 ,5 ]
Borghes, Roberto [1 ]
Carrato, Sergio [3 ]
Cautero, Giuseppe [1 ,2 ]
Fabiani, Sergio [2 ]
Giacomini, Gabriele [6 ]
Giuressi, Dario [1 ,2 ]
Kourousias, George [1 ]
Menk, Ralf Hendrik [1 ,2 ]
Picciotto, Antonino [6 ]
Piemonte, Claudio [6 ]
Rachevski, Alexandre [2 ]
Rashevskaya, Irina [7 ]
Stolfa, Andrea [1 ]
Vacchi, Andrea [2 ,8 ]
Zampa, Gianluigi [2 ]
Zampa, Nicola [2 ]
Zorzi, Nicola [6 ]
机构
[1] Elettra Sincrotrone Trieste SCpA, Str Statale SS14,Km 163-5, I-34149 Basovizza, Italy
[2] INFN Trieste, Padriciano 99, I-34149 Trieste, Italy
[3] Univ Trieste, Piazzale Europa 1, I-34127 Trieste, Italy
[4] Politecn Milan, Via Anzani 42, I-22100 Como, Italy
[5] Ist Nazl Fis Nucl, Via Celoria 16, I-20133 Milan, Italy
[6] Fdn Bruno Kessler, Via Sommarive 18, I-38123 Trento, Italy
[7] INFN TIFPA, Via Sommarive 14, I-38123 Trento, Italy
[8] Univ Udine, Via Sci 206, I-33100 Udine, Italy
关键词
Multi-element detectors and associated; VLSI electronics; Front-end electronics for detector readout; X-ray fluorescence (XRF) systems; Low energy XRF (LEXRF); Low leakage current SDDs; Soft X-rays;
D O I
10.1016/j.nima.2016.01.076
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The last decades have witnessed substantial efforts in the development of several detector technologies for X-ray fluorescence (XRF) applications. In spite of the increasing trend towards performing, cost-effective and reliable XRF systems, detectors for soft X-ray spectroscopy still remain a challenge, requiring further study, engineering and customization in order to yield effective and efficient systems. In this paper we report on the development, first characterization and tests of a novel multielement detector system based on low leakage current silicon drift detectors (SDD) coupled to ultra low noise custom CMOS preamplifiers for synchrotron-based low energy XRF. This new system exhibits the potential for improving the count rate by at least an order of magnitude resulting in ten-fold shorter dwell time at an energy resolution similar to that of single element silicon drift detectors. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 50 条
  • [1] Development of a low-energy X-ray fluorescence system combined with X-ray microscopy
    Gianoncelli, A.
    Klatka, T.
    Alberti, R.
    Bacescu, D.
    De Marco, A.
    Marcello, A.
    Longoni, A.
    Kaulich, B.
    Kiskinova, M.
    9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [2] A Low Energy X-Ray Fluorescence Spectrometer for Elemental Mapping X-Ray Microscopy
    Alberti, R.
    Longoni, A.
    Klatka, T.
    Guazzoni, C.
    Gianoncelli, A.
    Bacescu, D.
    Kaulich, B.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 839 - +
  • [3] A gas microstrip X-ray detector for soft energy fluorescence EXAFS
    Smith, AD
    Bateman, JE
    Derbyshire, GE
    Duxbury, DM
    Lipp, J
    Spill, EJ
    Stephenson, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1136 - 1139
  • [4] Soft x-ray microscopy
    Jacobsen, C
    TRENDS IN CELL BIOLOGY, 1999, 9 (02) : 44 - 47
  • [5] HERMES: a soft X-ray beamline dedicated to X-ray microscopy
    Belkhou, Rachid
    Stanescu, Stefan
    Swaraj, Sufal
    Besson, Adrien
    Ledoux, Milena
    Hajlaoui, Mahdi
    Dalle, Didier
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 968 - 979
  • [6] A soft X-ray beamline for transmission X-ray microscopy at ALBA
    Pereiro, E.
    Nicolas, J.
    Ferrer, S.
    Howells, M. R.
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 505 - 512
  • [7] Synchrotron radiation soft X-ray microscopy and low energy X-ray fluorescence to reveal elemental changes in spermatozoa treated with photobiomodulation therapy
    Zupin, Luisa
    Pascolo, Lorella
    Gianoncelli, Alessandra
    Gariani, Gianluca
    Luppi, Stefania
    Giolo, Elena
    Ottaviani, Giulia
    Crovella, Sergio
    Ricci, Giuseppe
    ANALYTICAL METHODS, 2020, 12 (29) : 3691 - 3696
  • [8] Soft X-ray characterization of halide perovskite film by scanning transmission X-ray microscopy
    Haeyeon Jun
    Hee Ryung Lee
    Denis Tondelier
    Bernard Geffroy
    Philip Schulz
    Jean-Éric Bourée
    Yvan Bonnassieux
    Sufal Swaraj
    Scientific Reports, 12
  • [9] Soft X-ray characterization of halide perovskite film by scanning transmission X-ray microscopy
    Jun, Haeyeon
    Lee, Hee Ryung
    Tondelier, Denis
    Geffroy, Bernard
    Schulz, Philip
    Bouree, Jean-Eric
    Bonnassieux, Yvan
    Swaraj, Sufal
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [10] Experimental characterization of the PERCIVAL soft X-ray detector
    Marras, A.
    Wunderer, C. B.
    Bayer, M.
    Correa, J.
    Goettlicher, P.
    Lange, S.
    Shevyakov, I.
    Smoljanin, S.
    Viti, M.
    Xia, Q.
    Zimmer, M.
    Das, D.
    Guerrini, N.
    Marsh, B.
    Sedgwick, I.
    Turchetta, R.
    Cautero, G.
    Giuressi, D.
    Khromova, A.
    Menk, R.
    Stebel, L.
    Fan, R.
    Marchal, J.
    Pedersen, U.
    Rees, N.
    Steadman, P.
    Sussmuth, M.
    Tartoni, N.
    Yousef, H.
    Hyun, H.
    Kim, K.
    Rah, S.
    Reza, S.
    Graafsma, H.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,