Simultaneous amperometric detection of electroinactive anions and cations in ion chromatography

被引:10
|
作者
Xu, Q
Xu, C
Wang, YP
Zhang, W
Jin, LT [1 ]
Tanaka, K
Haraguchi, H
Itoh, A
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
[2] Natl Ind Res Inst Nagoya, Kita Ku, Nagoya, Aichi 462, Japan
[3] Nagoya Univ, Sch Engn, Dept Appl Chem, Chikusa Ku, Nagoya, Aichi 4648603, Japan
关键词
D O I
10.1039/b005292m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric detector with two working electrodes modified with polydiphenylamine (PDPA) and polydiphenylamine dodecyl sulfate (PDPA-DS) was successfully used for the simultaneous determination of electroinactive anions (SO42-, Cl-, NO3-) and cations (Na+, NH4+ and K+) in single-column ion-exclusion chromatography-cation-exchange chromatography (IEC-CEC). The PDPA-DS chemically modified electrode (CME) was based on the incorporation of dodecyl sulfate (DS) into PDPA by electropolymerization of diphenylamine (DPA) in the presence of surfactant. The electrochemical responses against the anions and cations in differential pulse voltammetry were studied. A set of well-defined peaks of electroinactive anions and cations were obtained. The relative standard deviations (RSDs) of chromatographic peak height (nA) for anions were all < 4.4% and those for cations were all < 4.1%. The anions and cations were detected conveniently and reproducibly in the linear concentration range 6.0 x10(-6)-5.0 x 10(-3) mol L-1 and their correlation coefficients were all > 0.990. Their detection limits were investigated using 3s (where s represents the standard deviation of a blank solution, n = 11). They were 9.86 x 10(-7) mol L-1 for SO42-, 6.92 x 10(-7) mol L-1 for Cl-, 7.86 x 10(-7) mol L-1 for NO3-, 7.86 x 10(-7) mol L-1 for Na+, 9.79 x 10(-7) mol L-1 for NH4+ and 8.94 x 10(-7) mol L-1 for K+. The recoveries of the anions and cations by this method were in the range 97.8-103%. The proposed method was rapid, sensitive and simple and was successfully applied to the analysis of rainwater samples. Both electrodes were stable during a 1 week period of operation with no evidence of chemical or mechanical deterioration.
引用
收藏
页码:1799 / 1804
页数:6
相关论文
共 50 条
  • [1] Simultaneous separation and detection of anions and cations in ion chromatography
    Nesterenko, PN
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (6-7) : 311 - 319
  • [2] Amperometric detection studies of Nafion/indium hexacyanoferrate film for the determination of electroinactive cations in ion chromatography
    Q. Xu
    S. Zhang
    W. Zhang
    L. Jin
    K. Tanaka
    H. Haraguchi
    A. Itoh
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 241 - 245
  • [3] Polydiphenylamine-dodecyl sulfate films for the simultaneous amperometric determination of electroinactive anions and cations in ion-exclusion cation-exchange chromatography
    Qun Xu
    Chun Xu
    Yanping Wang
    Wen Zhang
    Litong Jin
    Kazuhiko Tanaka
    Hiroki Haraguchi
    Akihide Itoh
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 791 - 796
  • [4] Polydiphenylamine-dodecyl sulfate films for the simultaneous amperometric determination of electroinactive anions and cations in ion-exclusion cation-exchange chromatography
    Xu, Q
    Xu, C
    Wang, YP
    Zhang, W
    Jin, LT
    Tanaka, K
    Haraguchi, H
    Itoh, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (08): : 791 - 796
  • [5] Amperometric detection studies of Nafion/indium hexacyanoferrate film for the determination of electroinactive cations in ion chromatography
    Xu, Q
    Zhang, S
    Zhang, W
    Jin, LT
    Tanaka, K
    Haraguchi, H
    Itoh, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (03): : 241 - 245
  • [6] SIMULTANEOUS DETERMINATION OF ANIONS AND CATIONS BY ION CHROMATOGRAPHY
    NESTERENKO, PN
    TARASENKO, DA
    SHPIGUN, OA
    JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 49 (03) : 222 - 233
  • [7] Amperometric detection studies of poly-o-phenylenediamine film for the determination of electroinactive anions in ion-exclusion chromatography
    Xu, Q
    Xu, C
    Wang, YP
    Zhang, W
    Jin, LT
    Tanaka, K
    Haraguchi, H
    Itoh, A
    ANALYST, 2000, 125 (08) : 1453 - 1457
  • [8] SIMULTANEOUS DETERMINATION OF INORGANIC ANIONS AND CATIONS BY ION CHROMATOGRAPHY WITH INDIRECT PHOTOMETRIC DETECTION
    GAO, JZ
    BIAN, HJ
    HOU, JG
    KANG, JW
    JOURNAL OF CHROMATOGRAPHY A, 1993, 657 (01) : 95 - 101
  • [9] Simultaneous detection of anions and cations in mineral water by two dimensional ion chromatography
    Fa, Yun
    Yu, Yuexue
    Li, Fangfang
    Du, Fanglin
    Liang, Xiangfeng
    Liu, Huizhou
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1554 : 123 - 127
  • [10] Continuous and simultaneous determination of anions and cations in rainwater by ion chromatography
    Xu, Q
    Zhang, W
    Xu, C
    Jin, LT
    ANALYST, 2000, 125 (06) : 1065 - 1069