Development, Monte Carlo simulations and experimental evaluation of a 3D range-modulator for a complex target in scanned proton therapy

被引:14
|
作者
Simeonov, Yuri [1 ,2 ]
Weber, Uli [3 ]
Schuy, Christoph [3 ]
Engenhart-Cabillic, Rita [4 ,5 ]
Penchev, Petar [1 ,2 ]
Flatten, Veronika [1 ,2 ,4 ,5 ]
Zink, Klemens [1 ,4 ,5 ]
机构
[1] Univ Appl Sci, Inst Med Phys & Radiat Protect IMPS, Giessen, Germany
[2] Philipps Univ, Marburg, Germany
[3] GSI Helmholtzzentrum Schwerionenforsch GmbH, Biophys Div, Darmstadt, Germany
[4] Univ Med Ctr Giessen Marburg, Dept Radiotherapy & Radiooncol, Marburg, Germany
[5] Marburg Ion Beam Therapy Ctr MIT, Marburg, Germany
来源
关键词
particle therapy; proton therapy; 3D range-modulator; 3D printing; FLUKA; monte carlo simulation; FLUKA CODE; DESIGN; CHALLENGES;
D O I
10.1088/2057-1976/ac5937
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was to develop and manufacture a 3D range-modulator (3D RM) for a complex target contour for scanned proton therapy. The 3D RM is considered to be a viable technique for the very fast dose application in patient-specific tumors with only one fixed energy. The RM was developed based on a tumor from a patient CT and manufactured with high-quality 3D printing techniques with both polymer resin and aluminum. Monte Carlo simulations were utilized to investigate its modulating properties and the resulting dose distribution. Additionally, the simulation results were validated with measurements at the Marburg Ion-Beam Therapy Centre. For this purpose, a previously developed water phantom was used to conduct fast, automated high-resolution dose measurements. The results show a very good agreement between simulations and measurements and indicate that highly homogeneous dose distributions are possible. The delivered dose is conformed to the distal as well as to the proximal edge of the target. The 3D range-modulator concept combines a high degree of dose homogeneity and conformity, comparable to standard IMPT with very short irradiation times, promising clinically applicable dose distributions for lung and/or FLASH treatment, comparable and competitive to those from conventional irradiation techniques.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Development, Monte Carlo simulations and experimental evaluation of a 3D range-modulator for a complex target in scanned proton therapy
    Simeonov, Yuri
    Weber, Uli
    Schuy, Christoph
    Engenhart-Cabillic, Rita
    Penchev, Petar
    Flatten, Veronika
    Zink, Klemens
    Biomedical Physics and Engineering Express, 2022, 8 (03):
  • [2] 3D range-modulator for scanned particle therapy: development, Monte Carlo simulations and experimental evaluation
    Simeonov, Yuri
    Weber, Uli
    Penchev, Petar
    Ringbaek, Toke Printz
    Schuy, Christoph
    Brons, Stephan
    Engenhart-Cabillic, Rita
    Bliedtner, Jens
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (17): : 7075 - 7096
  • [3] 3D Range-Modulator for Scanned Particle Therapy: Development, Monte Carlo Simulations and Measurements
    Simeonov, Y.
    Penchev, P.
    Ringbaek, T. Printz
    Brons, S.
    Weber, U.
    Zink, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3504 - 3504
  • [4] Development and Monte Carlo simulations of a novel 3D range-modulator for proton therapy
    Simeonov, Y.
    Weber, U.
    Penchev, P.
    Ringbaek, T. Printz
    Zink, K.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S315 - S316
  • [5] 3D range-modulator for scanned particle therapy: development, Monte Carlo simulations and experimental evaluation (vol 62, pg 7075, 2017)
    Simeonov, Yuri
    Weber, Uli
    Penchev, Petar
    Ringbk, Toke Printz
    Schuy, Christoph
    Brons, Stephan
    Engenhart-Cabillic, Rita
    Bliedtner, Jens
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (19): : 7923 - 7923
  • [6] 3D Range Modulator for Proton Therapy: Development and Monte Carlo Simulations
    Simeonov, Y.
    Penchev, P.
    Printz, Ringbk T.
    Engenhart-Cabillic, R.
    Weber, U.
    Zink, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 : S10 - S10
  • [7] Dose Simulations of a Novel Aluminium-Alloy 3D Range-Modulator for Proton Therapy
    Simeonov, Y.
    Weber, U.
    Schuy, C.
    Penchev, P.
    Engenhart-Cabillic, R.
    Zink, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E749 - E749
  • [8] Dose simulations of a novel aluminium-alloy 3D range-modulator for proton therapy
    Simeonov, Y.
    Weber, U.
    Schuy, C.
    Penchev, P.
    Engenhart-Cabillic, R.
    Krause, H.
    Weisser, J.
    Zink, K.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S239 - S240
  • [9] Monte Carlo Simulations and Dose Measurements of a patient-specific 3D Range Modulator for Proton Therapy
    Simeonov, Y.
    Weber, U.
    Schuy, C.
    Penchev, P.
    Engenhart-Cabillic, R.
    Zink, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S178 - S179
  • [10] MC simulations and dose measurements of a patient-specific 3D range-modulator for proton therapy
    Simeonov, Y.
    Weber, U.
    Schuy, C.
    Zink, K.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S51 - S52