Predicting the permeability of trabecular bone by micro-computed tomography and finite element modeling

被引:32
|
作者
Sandino, Clara [1 ,2 ,3 ]
Kroliczek, Paul [1 ,2 ,3 ]
McErlain, David D. [1 ,2 ,3 ]
Boyd, Steven K. [1 ,2 ,3 ,4 ]
机构
[1] Univ Calgary, McCaig Inst Bone & Joint Hlth, Calgary, AB T2N 4Z6, Canada
[2] Univ Calgary, Schulich Sch Engn, Calgary, AB T2N 4Z6, Canada
[3] Univ Calgary, Roger Jackson Ctr Hlth & Wellness Res, Calgary, AB T2N 4Z6, Canada
[4] Univ Calgary, Fac Med, Dept Radiol, Calgary, AB T2N 4Z6, Canada
关键词
Permeability; Trabecular bone; Micro computed tomography; Finite element models; CANCELLOUS BONE; CEMENT INFILTRATION;
D O I
10.1016/j.jbiomech.2014.06.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The intrinsic permeability of bone plays an important role in the transport of nutrients and minerals within the tissue, and affects the mechanical stimuli that are related to the fate of the stem cells. The objective of this study was to establish a method to assess trabecular bone permeability using experimental and finite element (FE) modeling approaches based on micro computed tomography (mu CT) images. Human cadaveric tibia cube specimens (N=23) were scanned with gCT. The permeability was measured experimentally using a custom-developed constant-head permeameter, and computationally by a poroelastic formulation to simulate the fluid flow within the discretized bone matrix and pore phase. The average of the experimentally measured permeability was 4.84 x 10(-10) m(2) with a standard deviation of 3.70 x 10(-10) m(2). A regression model of the pCT determined that the maximum bone area to total area ratio (maxBA/TA) for all slices that are perpendicular to the direction of fluid flow explained 84% of the variability of the natural logarithm of the experimentally measured permeability. The 2D measure of maxBA/TA performed better than 3D measures in general, although some parameters were reasonably well associated with permeability such as bone volume ratio (BV/TV, r=-0.71), the bone surface/bone volume (BS/BV, r=0.73), and the trabecular thickness (TbTh, r=-0.71). The correlation between the permeability predicted with FE models and experimentally measured permeability was reasonable (r=0.69), but the FE approach did not accurately represent the wide variability of permeability measured experimentally. The results of this study suggest that the changes in the trabecular bone microarchitecture have an exponential relationship with permeability, and the use of ACT-based 2D measurement of maxBA/TA performs well at predicting permeability, thus providing a convenient approach to measure this important aspect affecting biomechanical functions in the tissue. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3129 / 3134
页数:6
相关论文
共 50 条
  • [1] Micro-computed tomography and compressive characterization of trabecular bone
    Catarina Vale, A.
    Pereira, M. F. C.
    Mauricio, A.
    Amaral, P.
    Rosa, L. G.
    Lopes, A.
    Rodrigues, A.
    Caetano-Lopes, J.
    Vidal, B.
    Monteiro, J.
    Fonseca, J. E.
    Canhao, H.
    Fatima Vaz, M.
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2013, 438 : 199 - 205
  • [2] Detection of trabecular bone microdamage by micro-computed tomography
    Wang, Xiang
    Masse, Daniel B.
    Leng, Huijie
    Hess, Kevin P.
    Ross, Ryan D.
    Roeder, Ryan K.
    Niebur, Glen L.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (15) : 3397 - 3403
  • [3] MODELING DENTAL IMPLANTS WITH FINITE ELEMENT ANALYSIS AND MICRO-COMPUTED TOMOGRAPHY
    Tsafnat, Naomi
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 719 - 720
  • [4] HOMOGENIZATION OF TRABECULAR BONE MICROSTRUCTURE BASED ON FINITE ELEMENT METHOD AND MICRO COMPUTED TOMOGRAPHY
    Janc, Krzysztof
    Kaminski, Jakub
    Tarasiuk, Jacek
    Bonnet, Anne-Sophie
    Lipinski, Paul
    [J]. 11TH WORLD CONGRESS ON COMPUTATIONAL MECHANICS; 5TH EUROPEAN CONFERENCE ON COMPUTATIONAL MECHANICS; 6TH EUROPEAN CONFERENCE ON COMPUTATIONAL FLUID DYNAMICS, VOLS II - IV, 2014, : 1012 - 1017
  • [5] Trabecular Bone Ratio of Mandible Using Micro-Computed Tomography in Korean
    Won, Sung-Yoon
    Kim, Sung-Hyun
    Kim, Sung-Tae
    Paik, Doo-Jin
    Song, Wu-Chul
    Koh, Ki-Seok
    Chung, Moon-Kyu
    Kim, Hee-Jin
    Hu, Kyung-Seok
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (03) : 920 - 924
  • [6] Structure and micro-computed tomography-based finite element modeling of Toucan beak
    Seki, Yasuaki
    Mackey, Mason
    Meyers, Marc A.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 9 : 1 - 8
  • [7] Predicting mouse vertebra strength with micro-computed tomography-derived finite element analysis
    Nyman, Jeffry S.
    Uppuganti, Sasidhar
    Makowski, Alexander J.
    Rowland, Barbara J.
    Merkel, Alyssa R.
    Sterling, Julie A.
    Bredbenner, Todd L.
    Perrien, Daniel S.
    [J]. BONEKEY REPORTS, 2015, 4
  • [8] The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing
    Ulrich, D
    Hildebrand, T
    VanRietbergen, B
    Muller, R
    Ruegsegger, P
    [J]. BONE RESEARCH IN BIOMECHANICS, 1997, 40 : 97 - 112
  • [9] Micro-computed tomography and mechanical evaluation of trabecular bone structure in osteopenic and osteoporotic fractures
    Ozan, Firat
    Pekedis, Mahmut
    Koyuncu, Semmi
    Altay, Taskin
    Yildiz, Hasan
    Kayali, Cemil
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (01)
  • [10] Micro-computed tomography evaluation of trabecular bone structure on loaded mice tail vertebrae
    Issever, AS
    Walsh, A
    Lu, Y
    Burghardt, A
    Lotz, JC
    Majumdar, S
    [J]. SPINE, 2003, 28 (02) : 123 - 128