Noninvasive cardiac output measurements are inaccurate in patients with severe aortic valve stenosis undergoing transcatheter aortic valve implantation

被引:1
|
作者
Yahagi, Musashi [1 ]
Omi, Kyuma [1 ]
Maeda, Takuma [2 ]
机构
[1] Hitachi Gen Hosp, Dept Anesthesiol, 317-0077 2-1-1 Jounanchou, Hitachi, Ibaraki 3170065, Japan
[2] Natl Cerebral & Cardiovasc Ctr, Dept Anesthesiol, Suita, Osaka, Japan
关键词
Aortic valve stenosis; Cardiac output; Pulse wave analysis; Thermodilution; Transcatheter aortic valve replacement; Vascular resistance; ARTERIAL-PRESSURE; TRENDING ABILITY; THERMODILUTION; AGREEMENT; ACCURACY; NEXFIN; METAANALYSIS; MONITORS;
D O I
10.4097/kja.21324
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Noninvasive cardiac output (CO) measured using ClearSight (TM) eliminates the need for intra-arterial catheter insertion. The purpose of this study was to examine the accuracy of non-invasive CO measurement in patients with severe aortic stenosis (AS). Methods: Twenty-eight patients undergoing elective transcatheter aortic valve implantation were prospectively enrolled in this study. The CO was simultaneously measured twice before and twice after valve deployment (total of four times) per patient, and the CO was compared between the ClearSight (COClearsight) system and the pulmonary artery catheter (PAC) thermodilution (COTD) method as a reference. The Bland-Altman analysis was used to compare the percentage errors between the methods. Results: A total of 112 paired data points were obtained. The percentage error between the COClearSight and COTD was 43.1%. The paired datasets were divided into the following groups according to the systemic vascular resistance index (SVRI): low (< 1,200 dyne s/cm(5)/m(2)) and normal (1,200-2,500 dyne s/cm(5)/m(2)). The percentage errors were 44.9% and 49.4%, respectively. The discrepancy of CO between CO(ClearSight)( )and COTD was not significantly correlated with SVRI (r = -0.06, P < 0.001). The polar plot analysis showed the trending ability of the COClearSight after artificial valve deployment was 51.1% which below the acceptable cut-off (92%). Conclusions: The accuracy and the trending ability of the ClearSight CO measurements were not acceptable in patients with severe AS. Therefore, the ClearSight system is not interchangeable with the PAC thermodilution for determining CO in this population.
引用
收藏
页码:151 / 159
页数:9
相关论文
共 50 条
  • [1] Comment on "Noninvasive cardiac output measurements are inaccurate in patients with severe aortic valve stenosis undergoing transcatheter aortic valve implantation"
    Giustiniano, Enrico
    Nisi, Fulvio
    Piccioni, Federico
    [J]. KOREAN JOURNAL OF ANESTHESIOLOGY, 2023, 76 (02) : 160 - 161
  • [2] Cardiac Output and Cerebral Blood Flow in Patients With Severe Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Implantation
    Vlastra, Wieneke
    Bronzwaer, Anne-Sophie
    Versteeg, Adriaan
    Bron, Esther
    Majoie, Charles
    Daemen, Mat
    Baan, Jan
    Piek, Jan
    Delewi, Ronak
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B683 - B683
  • [3] Aortic valve gradient and mortality in patients undergoing transcatheter aortic valve implantation for severe aortic stenosis
    Witberg, G.
    Barbash, I.
    Finkelstein, A.
    Assali, A.
    Segev, A.
    Halkin, A.
    Fefer, P.
    Ben-Shoshan, J.
    Konigstein, M.
    Guetta, V.
    Kornowski, R.
    Barsheshet, A.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 146 - 146
  • [4] Prevalence of cardiac amyloidosis in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation
    Floe, A.
    Holt, M. F.
    Kaya, E.
    Kvaslerud, A. B.
    Foss, S. K.
    Eek, C. H.
    Aaberge, L.
    Russell, K.
    Skulstad, H.
    Hodt, A.
    Gullestad, L.
    Gude, E.
    Broch, K.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2023, 25 : 366 - 367
  • [5] Aortic valve gradient and clinical outcome in patients undergoing transcatheter aortic valve implantation for severe aortic stenosis
    Witberg, G.
    Kornowski, R.
    Vaknin-Assa, H.
    Assali, A.
    Shapira, Y.
    Ben-Gal, T.
    Sagie, A.
    Barsheshet, A.
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 : 341 - 341
  • [6] Aortic Valve Gradient and Clinical Outcome in Patients Undergoing Transcatheter Aortic Valve Implantation for Severe Aortic Stenosis
    Witberg, Guy
    Barsheshet, Alon
    Assali, Abid
    Vaknin-Assa, Hana
    Shaul, Aviv A.
    Orvin, Katia
    Vaturi, Moti
    Schwartzenberg, Shmuel
    Shapira, Yaron
    Sagie, Alexander
    Kornowski, Ran
    [J]. CARDIOLOGY, 2016, 134 (02) : 128 - 135
  • [7] Cerebral Blood Flow in Patients with Severe Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Implantation
    Vlastra, Wieneke
    van Nieuwkerk, Astrid C.
    Bronzwaer, Anne-Sophie G. T.
    Versteeg, Adriaan
    Bron, Esther E.
    Niessen, Wiro J.
    Mutsaerts, Henk J. M. M.
    van Der Ster, Bjorn J. P.
    Majoie, Charles B. L. M.
    Biessels, Geert J.
    Nederveen, Aart J.
    Daemen, Mat J. A. P.
    van Osch, Matthias J. P.
    Baan, Jan
    Piek, Jan J.
    Van Lieshout, Johannes J.
    Delewi, Ronak
    [J]. JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2021, 69 (02) : 494 - 499
  • [8] TRANSCATHETER AORTIC VALVE IMPLANTATION FOR PATIENTS WITH BICUSPID SEVERE AORTIC VALVE STENOSIS
    Hayashida, Kentaro
    Lefevre, Thierry
    Chevalier, Bernard
    Hovasse, Thomas
    Romano, Mauro
    Garot, Philippe
    Farge, Arnaud
    Donzeau-Gouge, Patrick
    Bouvier, Erik
    Cormier, Bertrand
    Morice, Marie-Claude
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E4 - E4
  • [9] Transcatheter Aortic Valve Implantation for Patients With Severe Bicuspid Aortic Valve Stenosis
    Hayashida, Kentaro
    Bouvier, Erik
    Lefevre, Thierry
    Chevalier, Bernard
    Hovasse, Thomas
    Romano, Mauro
    Garot, Philippe
    Watanabe, Yusuke
    Farge, Arnaud
    Donzeau-Gouge, Patrick
    Cormier, Bertrand
    Morice, Marie-Claude
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) : 284 - 291
  • [10] Gender Differences in Patients with Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation
    Stortecky, Stefan
    Wenaweser, Peter
    Pilgrim, Thomas
    Kadner, Alexander
    Buellesfeld, Lutz
    Huber, Christoph
    Khattab, Ahmed
    Windecker, Stephan
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B258 - B259