A biosensor to detect penicillin residues in food

被引:0
|
作者
Delwiche, M
Cox, E
Goddeeris, B
Van Dorpe, C
De Baerdemaeker, J
Decuypere, E
Sansen, W
机构
[1] Univ Calif Davis, Dept Biol & Agr Engn, Davis, CA 95616 USA
[2] Katholieke Univ Leuven, Fac Agr & Appl Biol Sci, B-3001 Heverlee, Belgium
[3] State Univ Ghent, Fac Med Vet, B-9820 Merelbeke, Belgium
来源
TRANSACTIONS OF THE ASAE | 2000年 / 43卷 / 01期
关键词
biosensors; beta-lactam penicillins; drug residues; food engineering;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Avoidance of antibiotic residues is an essential element in the production of safe meat and dairy products. Our objectives in this research were to develop an enzyme immunoassay for beta-lactam penicillins, design an automated sensor to implement this assay, and evaluate the detection performance. An antibody capture with antigen competition assay was developed to run in polystyrene cuvets, with a test time of 13-15 min. A photometric sensor consisting of an optical head, electronic/fluidic board, and control computer was then designed to implement this assay. Results from manual assay tests on ampicillin in phosphate-buffered saline showed a slight reduction in optical density at 100 ng/mL and a significant reduction of 21% for 200 ng/mL. Sensor calibration tests gave similar results, indicating that the detection chemistry was successfully automated Higher affinity or avidity antibodies are needed to detect U.S. and European Community residue limits.
引用
收藏
页码:153 / 159
页数:7
相关论文
共 50 条
  • [1] A biosensor to detect penicillin residues in food
    Delwiche, M. (mjdelwiche@ucdavis.edu), 2000, ASAE, St. Joseph (43):
  • [2] COMPARISON OF SEVERAL ASSAY PROCEDURES TO DETECT PENICILLIN RESIDUES IN MILK
    JOHNSON, ME
    MARTIN, JH
    BAKER, RJ
    PARSONS, JG
    JOURNAL OF FOOD PROTECTION, 1977, 40 (11) : 785 - 789
  • [3] Immuno-strip biosensor system to detect enrofloxacin residues
    Kim, Young-Kee
    Kim, Hajin
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2009, 15 (02) : 229 - 232
  • [4] Application of Aptamer Biosensor in the Determination of Fluoroquinolones Residues in Food
    Song Y.
    Hu C.
    Wang C.
    Chen X.
    Huang Y.
    Journal of Chinese Institute of Food Science and Technology, 2021, 21 (08) : 409 - 419
  • [5] Aptamer biosensor for antibiotic residues detection in food analysis
    Yemin, Guo
    Xiangyou, Wang
    Xia, Sun
    Sensors and Transducers, 2013, 156 (09): : 368 - 373
  • [6] Need for rapid screening methods to detect chemical residues in food
    Lehotay, SJ
    PHOTONIC DETECTION AND INTERVENTION TECHNOLOGIES FOR SAFE FOOD, 2001, 4206 : 112 - 122
  • [7] Fast screening methods to detect antibiotic residues in food samples
    Chafer-Pericas, Consuelo
    Maquieira, Angel
    Puchades, Rosa
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (09) : 1038 - 1049
  • [8] Application of Aptamer Biosensor Technology to Detect Heavy Metal Lead in Food
    Sui, Jiachen
    Yu, Hansong
    Dai, Jiayu
    Song, Zhanyun
    Wang, Xianghui
    Zheng, Yan
    Yang, Qian
    Zhang, Jian
    Journal of Chinese Institute of Food Science and Technology, 2017, 17 (08) : 203 - 209
  • [9] EFFICIENT TESTING OF PENICILLIN TO DETECT PENICILLIN HYPERSENSITIVITY
    KUSAK, I
    HEMMER, W
    WANTKE, F
    GOTZ, M
    JARISCH, R
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1995, 95 (01) : 285 - 285
  • [10] Efficient testing of penicillin to detect penicillin hypersensitivity
    Kusak, I
    Hemmer, W
    Wantke, F
    Gotz, M
    Jarisch, R
    ALLERGOLOGIE, 1996, 19 (02) : 71 - 74