Biomechanical Measurement of Rabbit Cornea by a Modified Scheimpflug Device

被引:2
|
作者
Zhang, Bo [1 ]
Gu, Jianjun [1 ]
Zhang, Xiaoxiao [1 ]
Yang, Bin [1 ]
Wang, Zheng [2 ]
Zheng, Danying [1 ]
机构
[1] Sun Yat Sen Univ, State Key Lab Ophthalmol, Zhongshan Ophthalm Ctr, Guangzhou 510060, Guangdong, Peoples R China
[2] Guangzhou Aier Eye Hosp, Guangzhou 510288, Guangdong, Peoples R China
关键词
REPEATABILITY; PENTACAM; EXTENSIBILITY; ABERRATIONS; KERATOCONUS; SEGMENT; BOVINE; EYES;
D O I
10.1155/2016/8271762
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To explore the probability and variation in biomechanical measurements of rabbit cornea by a modified Scheimpflug device. Methods. A modified Scheimpflug device was developed by imaging anterior segment of the model imitating the intact eye at various posterior pressures. The eight isolated rabbit corneas were mounted on the Barron artificial chamber and images of the anterior segment were taken at posterior pressures of 15, 30, 45, 60, and 75 mm Hg by the device. The repeatability and reliability of the parameters including CCT, ACD, ACV, and CV were evaluated at each posterior pressure. All the variations of the parameters at the different posterior pressures were calculated. Results. All parameters showed good intraobserver reliability (Cronbach's alpha; intraclass correlation coefficient, alpha, ICC>0.96) and repeatability in the modified Scheimpflug device. With the increase of posterior pressures, the ratio of CCT decreased linearly and the bulk modulus gradually reduced to a platform. The increase of ACD was almost linear with the posterior pressures elevated. Conclusions. The modified Scheimpflug device was a valuable tool to investigate the biomechanics of the cornea. The posterior pressure 15-75 mm Hg range produced small viscoelastic deformations and nearly linear pressure-deformation response in the rabbit cornea.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Biomechanical properties of the cornea measurement using Scheimpflug noncontact tonometry in aniridia patients
    Wowra, Bogumil
    Dobrowolski, Dariusz
    Tarnawska, Dorota
    Wylegala, Edward
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [2] Biomechanical properties of rabbit cornea
    Nucci, C
    Lepore, D
    Pagliara, MM
    Molle, F
    Palma, S
    DeSantis, R
    Borzacchiello, A
    Nicolais, L
    Ambrosio, L
    Cerulli, L
    Scullica, L
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 379 - 379
  • [3] Ultrasonic measurement of the biomechanical properties of the cornea using a living rabbit model
    Prendiville, PL
    Wang, H
    Lee, RF
    Moreira, LB
    Chang, WV
    McDonnell, PJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 4627 - 4627
  • [4] Biomechanical properties of rabbit sclera and cornea
    Pagliara, MM
    Lepore, D
    Nucci, C
    Molle, F
    DeSantis, R
    Borzacchiello, A
    Ambrosio, L
    VISION RESEARCH, 1996, 36 : 319 - 319
  • [5] Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes
    Lee, Hun
    Kang, David Sung Yong
    Ha, Byoung Jin
    Choi, Jin Young
    Kim, Eung Kweon
    Seo, Kyoung Yul
    Kim, Tae-im
    YONSEI MEDICAL JOURNAL, 2018, 59 (09) : 1115 - 1122
  • [6] Evaluation of the biomechanical properties of the cornea in different glaucoma types with Corvis Scheimpflug technology
    Harbiyeli, Ibrahim Inan
    Erdem, Elif
    Uysal, Anil
    Binokay, Hulya
    Yagmur, Meltem
    CUKUROVA MEDICAL JOURNAL, 2022, 47 (01): : 426 - 435
  • [7] Biomechanical Properties of the Cornea Measured With the Dynamic Scheimpflug Analyzer in Young Healthy Adults
    Lee, Hun
    Kang, David Sung Yong
    Ha, Byoung Jin
    Choi, Jin Young
    Kim, Eung Kweon
    Seo, Kyoung Yul
    Kim, Ha Yan
    Kim, Tae-im
    CORNEA, 2017, 36 (01) : 53 - 58
  • [8] Effects of diabetes mellitus on biomechanical properties of the rabbit cornea
    Bao, FangJun
    Deng, ManLi
    Zheng, XiaoBo
    Li, LinNa
    Zhao, YiPing
    Cao, Si
    Yu, AYong
    Wang, QinMei
    Huang, JinHai
    Elsheikh, Ahmed
    EXPERIMENTAL EYE RESEARCH, 2017, 161 : 82 - 88
  • [9] Effects of Diabetes Mellitus on Biomechanical Properties of the Rabbit Cornea
    Bao, Fangjun
    Zheng, XiaoBo
    Zheng, YaRu
    Wang, QinMei
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [10] Characteristics of cornea biomechanical responses detected by noncontact Scheimpflug-based tonometer in eyes with glaucoma
    Jung, Youn Hea
    Park, Hae-Young Lopilly
    Park, Chan Kee
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)