First-pass myocardial perfusion cardiovascular magnetic resonance at 3 Tesla

被引:20
|
作者
Su, Mao-Yuan M.
Yang, Kai-Chien
Wu, Chau-Chung
Wu, Yen-Wen
Yu, Hsi-Yu
Tseng, Rung-Yu
Tseng, Wen-Yih I.
机构
[1] Natl Taiwan Univ, Ctr Optoelect Biomed, Coll Med, Taipei 10016, Taiwan
[2] Natl Yang Ming Univ, Inst Biomed Engn, Taipei 112, Taiwan
[3] Natl Taiwan Univ Hosp, Dept Internal Med, Taipei 100, Taiwan
[4] Natl Taiwan Univ Hosp, Dept Nucl Med, Taipei, Taiwan
[5] Natl Taiwan Univ Hosp, Dept Surg, Taipei 100, Taiwan
[6] Natl Taiwan Univ Hosp, Dept Med Imaging, Taipei, Taiwan
关键词
myocardial perfusion; 3; Tesla; ischemic heart disease;
D O I
10.1080/10976640601093661
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To test the feasibility of first-pass contrast-enhanced myocardial perfusion imaging at 3 Tesla and to evaluate the change in perfusion index between normal, remote and ischemic myocardium, we obtained perfusion index from healthy subjects and patients with coronary artery stenosis. Materials and Methods: First-pass contrast-enhanced perfusion imaging was performed on 12 patients and 32 age-matched healthy subjects in both rest and dipyridamole-induced stress states. After bolus injection of contrast agent, Gd-DTPA with dose of 0.025 mmol/kg body weight and injection time of 1.5 s, three short-axis images from apex to base of the left ventricle (LV) were acquired for 80 cardiac cycles using saturation recovery turbo FLASH sequence. The maximal upslope (Upslope) was derived from the signal-time curves of the LV cavity and myocardium to measure myocardial perfusion. Within 72 hours after cardiovascular magnetic resonance examination, patients received coronary angiography, and the results were correlated with cardiovascular magnetic resonance results. Results: Using our protocol of contrast agent administration, sufficient perfusion contrast was obtained without susceptibility-induced signal drop-out at the interface between LV cavity and the myocardium. In healthy volunteers, Upslope showed no dependence on myocardial segments or coronary territories. Upslope increased significantly from rest to stress in normal myocardium (0.09 +/- 0.03 vs. 0.16 +/- 0.05, p < 0.001) and remote myocardium (0.09 +/- 0.03 vs. 0.13 +/- 0.03, p < 0.001), whereas in ischemic myocardium the change was insignificant (0.11 +/- 0.03 vs. 0.10 +/- 0.04, p = ns). This resulted in significant difference in the ratio of Upslope at stress to that at rest, representing myocardial perfusion reserve, between ischemic and non-ischemic myocardium (0.96 +/- 0.41 vs. 1.71 +/- 0.42, p < 0.001 for ischemic vs. normal myocardium; 0.96 +/- 0.41 vs. 1.59 +/- 0.40, p < 0.001 for ischemic vs. remote myocardium). Conclusions: First-pass gadolinium-enhanced myocardial perfusion imaging at 3 Tesla is feasible. The Upslope ratio can differentiate ischemic from non-ischemic myocardium.
引用
收藏
页码:633 / 644
页数:12
相关论文
共 50 条
  • [1] Reproducibility of first-pass cardiovascular magnetic resonance myocardial perfusion
    Larghat, Abdulghani M.
    Maredia, Neil
    Biglands, John
    Greenwood, John P.
    Ball, Stephen G.
    Jerosch-Herold, Michael
    Radjenovic, Aleksandra
    Plein, Sven
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (04) : 865 - 874
  • [2] Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art
    Gerber, Bernhard L.
    Raman, Subha V.
    Nayak, Krishna
    Epstein, Frederick H.
    Ferreira, Pedro
    Axel, Leon
    Kraitchman, Dara L.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
  • [3] Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art
    Bernhard L Gerber
    Subha V Raman
    Krishna Nayak
    Frederick H Epstein
    Pedro Ferreira
    Leon Axel
    Dara L Kraitchman
    [J]. Journal of Cardiovascular Magnetic Resonance, 10
  • [4] A review of 3D first-pass, whole-heart, myocardial perfusion cardiovascular magnetic resonance
    Fair, Merlin J.
    Gatehouse, Peter D.
    DiBella, Edward V. R.
    Firmin, David N.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [5] A review of 3D first-pass, whole-heart, myocardial perfusion cardiovascular magnetic resonance
    Merlin J. Fair
    Peter D. Gatehouse
    Edward V. R. DiBella
    David N. Firmin
    [J]. Journal of Cardiovascular Magnetic Resonance, 17
  • [6] Contrast-enhanced first-pass myocardial perfusion magnetic resonance Imaging with parallel acquisition at 3.0 tesla
    Ruan, Chun
    Yang, Scott H.
    Cusi, Kenneth
    Gao, Feng
    Clarke, Geoffrey D.
    [J]. INVESTIGATIVE RADIOLOGY, 2007, 42 (06) : 352 - 360
  • [7] Perfusion phantom: An efficient and reproducible method to simulate myocardial first-pass perfusion measurements with cardiovascular magnetic resonance
    Chiribiri, Amedeo
    Schuster, Andreas
    Ishida, Masaki
    Hautvast, Gilion
    Zarinabad, Niloufar
    Morton, Geraint
    Otton, James
    Plein, Sven
    Breeuwer, Marcel
    Batchelor, Philip
    Schaeffter, Tobias
    Nagel, Eike
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) : 698 - 707
  • [8] Perfusion magnetic resonance imaging: Comparison of semiologic characteristics in first-pass perfusion of brain tumors at 1.5 and 3 Tesla
    Mauz, Natacha
    Krainik, Alexandre
    Tropres, Irene
    Lamalle, Laurent
    Sellier, Elodie
    Eker, Omer
    Tahon, Florence
    Le Bas, Jean-Francois
    Grand, Sylvie
    [J]. JOURNAL OF NEURORADIOLOGY, 2012, 39 (05) : 308 - 316
  • [9] 1125 Spiral first-pass myocardial perfusion imaging at 3 Tesla: feasibility study
    Taehoon Shin
    Kyunghyun Sung
    Gerald M Pohost
    Krishna S Nayak
    [J]. Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [10] Evaluation of an automated method for arterial input function detection for first-pass myocardial perfusion cardiovascular magnetic resonance
    Jacobs, Matthew
    Benovoy, Mitchel
    Chang, Lin-Ching
    Arai, Andrew E.
    Hsu, Li-Yueh