Accuracy and Radiation Dose of CT-Based Attenuation Correction for Small Animal PET: A Monte Carlo Simulation Study

被引:0
|
作者
Yang, Ching-Ching [1 ]
Chan, Kai-Chieh [1 ]
机构
[1] Tzu Chi Coll Technol, Dept Med Imaging & Radiol Sci, Hualien, Taiwan
关键词
Attenuation correction; small animal PET/CT; energy mapping; radiation exposure;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Small animal PET allows qualitative assessment and quantitative measurement of biochemical processes in vivo, but the accuracy and reproducibility of imaging results can be affected by several parameters. The first aim of this study was to investigate the performance of different CT-based attenuation correction strategies and assess the resulting impact on PET images. The absorbed dose in different tissues caused by scanning procedures was also discussed to minimize biologic damage generated by radiation exposure due to PET/CT scanning. A small animal PET/CT system was modeled based on Monte Carlo simulation to generate imaging results and dose distribution. Three energy mapping methods, including the bilinear scaling method, the dual-energy method and the hybrid method which combines the kVp conversion and the dual-energy method, were investigated comparatively through assessing the accuracy of estimating linear attenuation coefficient at 511 keV and the bias introduced into PET quantification results due to CT-based attenuation correction. Our results showed that the hybrid method outperformed the bilinear scaling method, while the dual-energy method achieved the highest accuracy among the three energy mapping methods. Overall, the accuracy of PET quantification results have similar trend as that for the estimation of linear attenuation coefficients, whereas the differences between the three methods are more obvious in the estimation of linear attenuation coefficients than in the PET quantification results. With regards to radiation exposure from CT, the absorbed dose ranged between 7.29-45.58 mGy for 50-kVp scan and between 6.61-39.28 mGy for 80-kVp scan. For 18F radioactivity concentration of 1.86x10(5) Bq/ml, the PET absorbed dose was around 24 cGy for tumor with a target-to-background ratio of 8. The radiation levels for CT scans are not lethal to the animal, but concurrent use of PET in longitudinal study can increase the risk of biological effects. The hybrid method has been demonstrated to be an energy mapping method that could perform accurate conversion from CT numbers to linear attenuation coefficients at 511 keV without increasing CT radiation exposure, so it should be a proper method for longitudinal imaging studies performed on small animal PET/CT systems.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Accuracy and reproducibility of tumor detection on small animal PET/CT: A Monte Carlo simulation study
    Yang, Ching-Ching
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [2] Accuracy of CT-based attenuation correction in PET/CT bone imaging
    Abella, Monica
    Alessio, Adam M.
    Mankoff, David A.
    MacDonald, Lawrence R.
    Jose Vaquero, Juan
    Desco, Manuel
    Kinahan, Paul E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09):
  • [3] Accuracy of CT-Based attenuation correction in bone Imaging with PET/CT
    Abella, M.
    Mankof, D.
    Vaquero, J. J.
    Desco, M.
    Kinahan, P. E.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4485 - +
  • [4] Use of tube current modulation to minimize radiation dose in CT-based PET attenuation correction
    Turkington, Timothy
    Lokitz, Stephen
    Colsher, James
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [5] Experimental evaluation of the bilinear transformation used in the CT-based attenuation correction for small animal PET imaging
    Yu, Jianhua
    Seidel, Jurgen
    Pomper, Martin
    Tsui, Benjamin M. W.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3747 - +
  • [6] Optimization of CT Scanning Protocols for Small Animal PET/CT Studies: A Monte Carlo Simulation Study
    Yang, Ching-Ching
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (04) : 925 - 931
  • [7] Impact of X-ray Scatter When Using CT-based Attenuation Correction in PET: A Monte Carlo Investigation
    Zaidi, Habib
    Ay, Mohammad Reza
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2161 - 2165
  • [8] Low-dose CT scans for CT-based attenuation correction in PET/CT imaging.
    Bai, C
    Shao, L
    Da Silva, AJ
    Zhao, Z
    Hines, H
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 104P - 105P
  • [9] Automated CT-based Attenuation Correction for Preclinical Multimodality PET/CT
    Chen, Mu
    Osborne, Dustin
    Gleason, Shaun
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4043 - +
  • [10] Simulation-based Assessment of the Impact of Contrast Medium on CT-based Attenuation Correction in PET
    Ay, Mohamad Reza
    Zaidi, Habib
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2731 - 2735