Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes

被引:14
|
作者
Fernandez-Vega, Luis [1 ,2 ]
Madrid-Costa, David [1 ,3 ]
Alfonso, Jose F. [1 ,2 ]
Poo-Lopez, Arancha [1 ]
Montes-Mico, Robert [4 ]
机构
[1] Inst Oftalmol Fernandez Vega, Oviedo 33012, Spain
[2] Univ Oviedo, Sch Med, Dept Surg, Oviedo, Spain
[3] Univ Europea Madrid, Opt & Optometry Dept, Madrid, Spain
[4] Univ Valencia, Fac Phys, Dept Opt, E-46003 Valencia, Spain
关键词
Acri.LISA; Multifocal IOL; Myopia; Visual acuity; RETINAL-DETACHMENT; CONTRAST SENSITIVITY; VISUAL PERFORMANCE; DISTANCE; QUALITY; EXTRACTION; RISK;
D O I
10.1177/112067211002000111
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low-moderate myopia. METHODS. A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low-moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (CS) under photopic (85 cd/m(2)) and mesopic (5 cd/m2) conditions were determined. RESULTS. At the 6-month postoperative visit, there were no statistically significant differences in monocular and binocular BCVA (p=0.13 and p=0.22, respectively). Monocular and binocular BCNVA was comparable between the groups (p=0.26 and p=0.09, respectively). The mean binocular BCIVA changed significantly as a function of the distance of the test (p<0.01) in both groups, and there were no statistically significant differences between groups at any distance. Monocular and binocular CS under photopic and mesopic conditions was similar between both groups (p>0.01). CONCLUSIONS. Bilateral implantation of the Acri.LISA 366D in high myopic eyes provides a satisfactory full range of vision comparable to that obtained in low-moderate myopic eyes. (Eur J Ophthalmol 2010; 20: 83-9)
引用
收藏
页码:83 / 89
页数:7
相关论文
共 50 条
  • [1] Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Baamonde, Begona
    Orti, Susana
    Montes-Mico, Robert
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (02) : 125 - 131
  • [2] Prospective study of the Acri.LISA bifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Senaris, Ana
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11): : 1930 - 1935
  • [3] Contrast Sensitivity Comparison Between AcrySof ReSTOR and Acri.LISA Aspheric Intraocular Lenses
    Alfonso, Jose F.
    Puchades, Cristina
    Fernandez-Vega, Luis
    Merayo, Carmen
    Montes-Mico, Robert
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (07) : 471 - 477
  • [4] Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens
    Fernandez-Vega, Luis
    Alfonso, Jose F.
    Baamonde, Begona
    Madrid-Costa, David
    Montes-Mico, Robert
    Lozano, Javier
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) : 214 - 220
  • [5] Retinal detachment in myopic eyes after phakic intraocular lens implantation
    Ruiz-Moreno, JM
    Montero, JA
    de la Vega, C
    Alió, JL
    Zapater, P
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (03) : 247 - 252
  • [6] Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lens
    Fernandez-Vega, Luis
    Alfonso, Jose F.
    Baamonde, M. Begona
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11): : 1913 - 1917
  • [7] Intraocular lens power in myopic eyes
    Savini, Giacomo
    Ducoli, Pietro
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06): : 1340 - 1341
  • [8] Refractive lens exchange with the Acri.Twin asymmetric diffractive bifocal intraocular lens system
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Orti, Susana
    Montes-Mico, Robert
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (03) : 509 - 516
  • [9] Bilateral big-bag intraocular lens implant for highly myopic eyes
    Bhatnagar, A.
    Somanathan, S.
    Scott, R. A. H.
    EYE, 2006, 20 (12) : 1463 - 1464
  • [10] Bilateral big-bag intraocular lens implant for highly myopic eyes
    A Bhatnagar
    S Somanathan
    R A H Scott
    Eye, 2006, 20 : 1463 - 1464