Scleral fixation of one piece intraocular lens by injector implantation

被引:8
|
作者
Can, Ertugrul [1 ]
Basaran, Resat [1 ]
Gul, Adem [1 ]
Birinci, Hakki [1 ]
机构
[1] Ondokuz Mayis Univ, Dept Ophthalmol, Fac Med, TR-55139 Samsun, Turkey
关键词
Capsular; dehiscence; foldable intraocular lens; injector implantation; scleral fixation; SMALL-INCISION TECHNIQUE; TRANSSCLERAL FIXATION; TRANSSDERAL FIXATION;
D O I
10.4103/0301-4738.141042
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim of Study: With an ab-interno technique of transscleral suturing of current one-piece posterior chamber intraocular lenses (PC IOLs) by injector implantation in the absence of capsular support, we aimed to demonstrate the possibility of the implantation of one-piece acrylic PC IOLs that might be produced in the future for only scleral fixation through small clear corneal incision. Materials and Methods: Case report and literature review. Results: This procedure has been performed in eight aphakic eyes with four different types of IOLs. Good centration was achieved with minimal technical effort. All patients had well-centered and stable lenses postoperatively during 9-18 months follow-up. Conclusion: We managed to decrease the risks of surgical trauma and intricate surgical maneuvers requirement. With this technique, excessive fluid leakage and consecutive hypotony can be minimized.
引用
收藏
页码:857 / 860
页数:4
相关论文
共 50 条
  • [1] Re: Scleral fixation of one piece intraocular lens by injector implantation
    Can, Ertugrul
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2015, 63 (05) : 466 - U112
  • [2] Scleral Fixation of a One-Piece Toric Intraocular Lens
    Emanuel, Matthew E.
    Randleman, J. Bradley
    Masket, Samuel
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (02) : 140 - 142
  • [3] Injector implantation of a scleral-fixated intraocular lens
    Szurman, P.
    Petermeier, K.
    Jaissle, G. B.
    Spitzer, M. S.
    Bartz-Schmidt, K. U.
    [J]. OPHTHALMOLOGE, 2006, 103 (12): : 1020 - 1026
  • [4] Scleral fixation of a single-piece multifocal intraocular lens
    Can, Ertugrul
    Basaran, M. Resat
    Gul, Adem
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (02) : 249 - 251
  • [5] Is scleral fixation a safe procedure for intraocular lens implantation?
    Paolo Lanzetta
    Francesco M. Bandello
    Gianni Virgili
    Sabrina Crovato
    Ugo Menchini
    [J]. Documenta Ophthalmologica, 1999, 97 : 317 - 323
  • [6] Is scleral fixation a safe procedure for intraocular lens implantation?
    Lanzetta, P
    Bandello, FM
    Virgili, G
    Crovato, S
    Menchini, U
    [J]. DOCUMENTA OPHTHALMOLOGICA, 1999, 97 (3-4) : 317 - 324
  • [7] Transscleral Fixation by Injector Implantation of a Foldable Intraocular Lens
    Choi, Kyung Seek
    Park, Sung Yong
    Sun, Hae Jung
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2010, 41 (02) : 272 - 275
  • [8] In situ Scleral Suture Fixation of an Injector-delivered Intraocular Lens
    Kim, Ho Joong
    Cho, Yang Kyung
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2024, 65 (05): : 348 - 353
  • [9] An Electrocoagulation Fixation Technique for One-Piece Intraocular Lens Scleral Flapless Fixation With Sutures Without Knots
    Si, Shancheng
    Zhang, Jianhui
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (12): : 2068 - 2071
  • [10] Secondary intraocular lens implantation using scleral suture fixation
    Szurman, P.
    Gekeler, K.
    [J]. OPHTHALMOLOGE, 2014, 111 (03): : 217 - 223