Novel technology of non-invasive cerebrovascular autoregulation monitoring

被引:7
|
作者
Petkus, Vytautas [1 ]
Krakauskaite, Solventa [1 ]
Chomskis, Romanas [1 ]
Bartusis, Laimonas [1 ]
Ragauskas, Arminas [1 ]
Preiksaitis, Aidanas [2 ,3 ]
Rocka, Saulius [2 ,3 ]
机构
[1] Kaunas Univ Technol, Telemat Sci Ctr, Kaunas, Lithuania
[2] Vilnius Univ Fac Med, Neurol Clin, Ctr Neuroangio Surg, Vilnius, Lithuania
[3] Vilnius Univ Fac Med, Clin Neuroangio Surg, Ctr Neuroangio Surg, Vilnius, Lithuania
基金
欧盟第七框架计划;
关键词
cerebrovascular autoregulation; patient non-invasive monitoring; intracranial waves; medical diagnosis; HEAD-INJURED PATIENTS; CEREBRAL AUTOREGULATION; BLOOD-PRESSURE; REACTIVITY; DISEASE; INDEX;
D O I
10.1109/CBMS.2014.44
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A novel technology for non-invasive cerebrovascular autoregulation (CA) status monitoring is presented. This fully non-invasive CA monitor is based on ultrasonic time-of-flight (TOF) measurement of cerebral blood volume pulsations within the brain parenchyma, processing of volumetric waves, and calculation of CA estimation indexes without using any additional arterial blood pressure (ABP) measurements. The CA status is estimated by extracting informative and reference slow waves from non-invasively measured TOF signals and by calculating Pearson's correlation coefficient between these waves as a CA index. The analysis of the signal extracted from the envelope of noninvasively measured pulse waves showed good agreement between this signal and ABP waves (r=0.68). Consequently, it shows that this signal might be used instead of ABP waves as a reference signal for calculation of the CA estimation indexes. Comparative invasive versus non-invasive CA monitoring study of 11 traumatic brain injury patients showed that correlation between invasively measured CA index and fully non-invasively measured CA index (no arterial line) was r=0.75. The proposed innovative CA real-time monitoring method gives us new possibilities to perform estimation of the CA status from intracranial waves only as well as to exclude the ABP line's errors and artifacts from the measurement results.
引用
收藏
页码:427 / 430
页数:4
相关论文
共 50 条
  • [1] Non-invasive technology for monitoring of cerebrovascular autoregulation
    Ragauskas, A.
    Daubaris, G.
    Petkus, V.
    Raisutis, R.
    Chomskis, R.
    Sliteris, R.
    Deksnys, V.
    Guzaitis, J.
    Lengvinas, G.
    Rugaitis, A.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2008, (05) : 93 - 96
  • [2] Novel Method and Device for Fully Non-Invasive Cerebrovascular Autoregulation Monitoring
    Petkus, V.
    Preiksaitis, A.
    Krakauskaite, S.
    Chomskis, R.
    Rocka, S.
    Kalasauskiene, A.
    Kalvaitis, E.
    Ragauskas, A.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2014, 20 (08) : 24 - 29
  • [3] Clinical study of continuous non-invasive cerebrovascular autoregulation monitoring in neurosurgical ICU
    Ragauskas, A
    Daubaris, G
    Petkus, V
    Ragaisis, V
    Ursino, M
    INTRACRANIAL PRESSURE AND BRAIN MONITORING XII, 2005, 95 : 367 - 370
  • [4] Non-invasive Cerebrovascular Monitoring
    Kashif, Faisal M.
    Heldt, Thomas
    Novak, Vera
    Czosnyka, Marek
    Verghese, George C.
    STROKE, 2010, 41 (04) : E237 - E237
  • [5] Ultrasonic non-invasive cerebrovascular autoregulation monitoring method without the need of arterial line
    Petkus, V.
    Preiksaitis, A.
    Rocka, S.
    Chomskis, R.
    Bartusis, L.
    Ragauskas, A.
    CEREBROVASCULAR DISEASES, 2014, 37 : 53 - 53
  • [7] Non-invasive Monitoring of Dynamic Cerebrovascular Autoregulation Using Near Infrared Spectroscopy and the Finometer Photoplethysmograph
    Bindra, Jessica
    Pham, Paul
    Aneman, Anders
    Chuan, Alwin
    Jaeger, Matthias
    NEUROCRITICAL CARE, 2016, 24 (03) : 442 - 447
  • [8] Non-invasive Monitoring of Dynamic Cerebrovascular Autoregulation Using Near Infrared Spectroscopy and the Finometer Photoplethysmograph
    Jessica Bindra
    Paul Pham
    Anders Aneman
    Alwin Chuan
    Matthias Jaeger
    Neurocritical Care, 2016, 24 : 442 - 447
  • [9] PROSPECTIVE COMPARATIVE CLINICAL STUDY OF NON-INVASIVE CEREBROVASCULAR AUTOREGULATION MONITOR
    Petkus, V
    Zakelis, R.
    Bartusis, L.
    Krakauskaite, S.
    Preiksaitis, A.
    Chomskis, R.
    Rocka, S.
    Ragauskas, A.
    INTERNATIONAL JOURNAL OF STROKE, 2017, 12 : 54 - 54
  • [10] Technology for non-invasive monitoring of glucose
    Heise, HM
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 2159 - 2161