摘要
The gas chromatography mass spectrometry (GC-MS) deconvolution reporting software (DRS) from Agilent Technologies has been evaluated for its ability as a screening tool to detect a large number of pesticides in incurred and fortified samples extracted with acetone/dichloromethane/light petroleum (Mini-Luke method). The detection of pesticides is based on fixed retention times using retention time locking (RTL) and full scan mass spectral comparison with a partly customer built automated mass spectral deconvolution and identification system (AMDIS) database. The GC-MS was equipped with a programmable temperature vaporising (PTV) injector system which enables more sample to be injected. In a blind study of 52 real samples a total number of 158 incurred pesticides were found. In addition to the 85 pesticides found by manual interpretation of GC-NPD/ECD chromatograms, the DRS revealed 73 more pesticides (+46%). The DRS system also shows its potential to discover pesticides which are normally not searched for (EPN in long beans from Thailand). A spiking experiment was performed to blank matrices of apple, orange and lettuce with 177 different pesticides at concentration levels 0.02 and 0.1 mg/kg. The samples were analysed on GC-MS full scan and the AMDIS match factor was used as a mass spectral quality criterion. The threshold level of the AMDIS match factor was set at 20 to eliminate most of the false positives. AMDIS match factors from 20 up to 69 are regarded only as indication of a positive hit and must be followed by manual interpretation. Pesticides giving AMDIS match factors at >= 70 are regarded as identified. To simplify and decrease the large amount of data generated at each concentration level, the AMDIS match factors >= 20 was averaged (mean AMF) for each pesticide including the commodities and their replicates. Among 177 different pesticides spiked at 0.02 and 0.1 mg/kg level, the percentage of mean AMF values >= 70 were 23% and 80%, respectively. For 531 individual detections of pesticides (177 pesticides x 3 replicates) giving AMDIS match factor 20 in apple, orange and lettuce, the detection rates at 0.02 mg/kg were 71%, 63% and 72%, respectively. For the 0.1 mg/kg level the detection rates were 89%, 85% and 89%, respectively. In real samples some manual interpretation must be performed in addition. However, screening by GC-MS/DRS is about 5-10 times faster compared to screening with GC-NPD/ECD because the time used for manual interpretation is much shorter and there is no need for re-injection on GC-MS for the identification of suspect peaks found on GC-NPD/ECD. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2056 / 2064
页数:9
相关论文
共 50 条
  • [1] Pesticide Residues Analysis in Iranian Fruits and Vegetables by Gas Chromatography-Mass Spectrometry
    Hadian, Zahra
    Eslamizad, Sandra
    Yazdanpanah, Hassan
    [J]. IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2019, 18 (01): : 275 - 285
  • [2] Analysis of pesticide residues in fruits, vegetables, and milk by gas chromatography/tandem mass spectrometry
    Sheridan, RS
    Meola, JR
    [J]. JOURNAL OF AOAC INTERNATIONAL, 1999, 82 (04) : 982 - 990
  • [3] Determination of 193 pesticide residues in vegetables and fruits by gas chromatography-mass spectrometry
    Cui Shuhua
    Chen Weishuang
    Qian Jialiang
    Duan Hao
    Liu Tongying
    Zhang Lidong
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (09) : 885 - 893
  • [4] Pesticide residues in fruits and vegetables in Jordan using liquid chromatography/tandem mass spectrometry
    Algharibeh, Ghaith Radwan
    AlFararjeh, Malik Salah
    [J]. FOOD ADDITIVES & CONTAMINANTS PART B-SURVEILLANCE, 2019, 12 (01): : 65 - 73
  • [5] Screening of The Presence Organophosphates And Organochlorines Pesticide Residues in Vegetables And Fruits Using Gas Chromatography-Mass Spectrometry
    Putri, Dillani
    Aryana, Nurhani
    Aristiawan, Yosi
    Styarini, Dyah
    [J]. INTERNATIONAL SYMPOSIUM ON APPLIED CHEMISTRY (ISAC) 2016, 2017, 1803
  • [6] Rapid determination of 129 pesticide residues in vegetables and fruits by gas chromatography-triple quadrupole mass spectrometry
    Ma Zhiling
    Zhao Wen
    Li Lingyun
    Zheng Shuning
    Lin Huan
    Zhang Yanguo
    Gao Qingzhen
    Liu Su
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (03) : 228 - 239
  • [7] Application of Fast Gas Chromatography–Mass Spectrometry in Combination with the QuEChERS Method for the Determination of Pesticide Residues in Fruits and Vegetables
    Laura Cherta
    Joaquim Beltran
    Francisco López
    Félix Hernández
    [J]. Food Analytical Methods, 2013, 6 : 1170 - 1187
  • [8] Analysis of pesticide residues in fruits and vegetables using gas chromatography-high resolution time-of-flight mass spectrometry
    Belmonte Valles, Noelia
    Ucles, Samanta
    Besil, Natalia
    Mezcua, Milagros
    Fernandez-Alba, Amadeo R.
    [J]. ANALYTICAL METHODS, 2015, 7 (05) : 2162 - 2171
  • [9] An Accurate-Mass Database for Screening Pesticide Residues in Fruits and Vegetables by Gas Chromatography-Time-of-Flight Mass Spectrometry
    Belmonte, Noelia
    Ucles, Samanta
    Gamon, Miguel
    Ferrer, Carmen
    Mezcua, Milagros
    Fernandez-Alba, Amadeo R.
    [J]. LC GC NORTH AMERICA, 2015, : 45 - 50
  • [10] Practical aspects in gas chromatography-mass spectrometry for the analysis of pesticide residues in exotic fruits
    Espana Amortegui, Julio Cesar
    Guerrero Dallos, Jairo Arturo
    [J]. FOOD CHEMISTRY, 2015, 182 : 14 - 22