A novel sensitive electrochemical sensor based on in-situ polymerized molecularly imprinted membranes at graphene modified electrode for artemisinin determination

被引:87
|
作者
Bai, Huiping [1 ]
Wang, Chunqiong [1 ]
Chen, Jing [1 ]
Peng, Jun [1 ]
Cao, Qiue [1 ]
机构
[1] Yunnan Univ, Minist Educ, Key Lab Med Chem Nat Resource, Sch Chem Sci & Technol, Kunming 650091, Peoples R China
来源
基金
中国国家自然科学基金; 国家教育部博士点专项基金资助;
关键词
Artemisinin; Graphene; Electrochemical sensor; Molecular imprinted membrane; In-situ polymerization; PERFORMANCE LIQUID-CHROMATOGRAPHY; ANNUA L; CARBON NANOTUBES; MASS-SPECTROMETRY; ACID; FILM; NANOPARTICLES; QUANTIFICATION; EXTRACTS; LAYER;
D O I
10.1016/j.bios.2014.09.034
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To develop a rapid and simple method for sensitive determination of artemisinin (ART) in complicated matrices, a novel electrochemical sensor was constructed by in-situ polymerization of ART-imprinted membranes (ART-MIMs) on the surface of graphene (G) modified glassy carbon electrode (GCE) using acrylamide (AM) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linking agent after the experimental parameters for the preparation of ART-MIMs such as functional monomer, molar ratio of template, monomer and cross-linking agent together with extraction condition were optimized. Under the optimal conditions, the sensor named as ART-MIM/G/GCE exhibited a good selectivity, high sensitivity and considerably better resistance against some analogs of artemisinin such as dihydroartemisinin (DHA), artemether (ARM) and artesunate (ARTS). The calibration graph for the determination of artemisinin by the sensor was linear in the range of 1.0 x 10(-8) mol L-1 to 4.0 x 10(-5) mol L-1 with the detection limit of 2.0 x 10(-9) mol L-1. Meanwhile, this sensor possessed of good regeneration, stability and practicability. It could retain more than 94% of its original response after used at least 80 times or stored in water at room temperature for 60 days. The obtained sensor was successfully applied to determine the contents of artemisinin in the extract of Artemisia annua L with the relative standard deviation (RSD) of less than 3.5% (n=5). (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:352 / 358
页数:7
相关论文
共 50 条
  • [1] Sensitive Artemisinin Electrochemical Sensor Based on Polymerized Molecularly Imprinted Membranes
    Zhou, Ji
    Sun, Xinyu
    Wang, Kai
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (04): : 3114 - 3122
  • [2] Electrochemical sensor based on in situ polymerized ion-imprinted membranes at graphene modified electrode for palladium determination
    Bai, Huiping
    Wang, Shixiong
    Liu, Peng
    Xiong, Caiyun
    Zhang, Kainan
    Cao, Qiue
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 771 : 29 - 36
  • [3] Sensitive detection of ketamine with an electrochemical sensor based on UV-induced polymerized molecularly imprinted membranes at graphene and MOFs modified electrode
    Fu, Kaixin
    Zhang, Ruilin
    He, Jingcheng
    Bai, Huiping
    Zhang, Genlin
    BIOSENSORS & BIOELECTRONICS, 2019, 143
  • [4] An electrochemical sensor for the determination of phoxim based on a graphene modified electrode and molecularly imprinted polymer
    Tan, Xuecai
    Wu, Jiawen
    Hu, Qi
    Li, Xiaoyu
    Li, Pengfei
    Yu, Huicheng
    Li, Xiaoyan
    Lei, Fuhou
    ANALYTICAL METHODS, 2015, 7 (11) : 4786 - 4792
  • [5] Electrochemical Sensor for Determination of Chlorpyrifos Based on Graphene Modified Electrode and Molecularly Imprinted Polymer
    Tan Xue-Cai
    Wu Jia-Wen
    Hu Qi
    Li Xiao-Yu
    Li Peng-Fei
    Yu Hui-Cheng
    Li Xiao-Yan
    Lei Fu-Hou
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (03) : 387 - 393
  • [6] Electrochemical Sensor Based on Molecularly Imprinted Polymer and Graphene Modified Electrode for Determination of Methyl Parathion
    Wu, Jia-Wen
    Xie, Zhou-Jian
    Tan, Xue-Cai
    Hu, Qi
    Lei, Fu-Hou
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (06) : 757 - 764
  • [7] Molecularly Imprinted Polymer (MIP) Electrochemical Sensor based on Graphene Modified Platinum Electrode for Sertraline Determination
    Milani-Hosseini, Mohammad-Reza
    Karamdoust, Sanaz
    Bahman, Mina
    Motaharian, Ali
    Mohammadsadegh, Saeideh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (01): : 128 - 140
  • [8] Electrochemical sensor based on molecularly imprinted membranes at platinum nanoparticles-modified electrode for determination of 17β-estradiol
    Yuan, Lihua
    Zhang, Jun
    Zhou, Ping
    Chen, Jiaxing
    Wang, Ruoyu
    Wen, Tingting
    Li, Yun
    Zhou, Xuemin
    Jiang, Huijun
    BIOSENSORS & BIOELECTRONICS, 2011, 29 (01): : 29 - 33
  • [9] An electrochemical sensor based on molecularly Imprinted membranes on a P-ATP-AuNP modified electrode for the determination of acrylamide
    Wang, Qiuyun
    Ji, Jian
    Jiang, Donglei
    Wang, Yao
    Zhang, Yinzhi
    Sun, Xiulan
    ANALYTICAL METHODS, 2014, 6 (16) : 6452 - 6458
  • [10] Molecularly imprinted electrochemical sensor based on nickel nanoparticles-graphene nanocomposites modified electrode for determination of tetrabromobisphenol A
    Chen, Hongjun
    Zhang, Zhaohui
    Cai, Rong
    Rao, Wei
    Long, Fang
    ELECTROCHIMICA ACTA, 2014, 117 : 385 - 392