Numerical evaluation of the thermal performance of different types of double glazing flat-plate solar air collectors

被引:21
|
作者
Chen, C. Q. [1 ]
Diao, Y. H. [1 ]
Zhao, Y. H. [1 ]
Wang, Z. Y. [1 ]
Zhu, T. T. [2 ,3 ]
Wang, T. Y. [1 ]
Liang, L. [1 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient, Beijing 100124, Peoples R China
[2] Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, 409 Guangrong Rd, Tianjin 300134, Peoples R China
[3] Tech Univ Denmark, Dept Mech Engn, Nils Koppels Alle,Bldg 403, DK-2800 Lyngby, Denmark
基金
中国国家自然科学基金;
关键词
Flat-plate solar air collector; Double glazing; Vacuum glazing; Numerical simulation; OPTIMIZATION; PARAMETERS; INSULATION; ENERGY;
D O I
10.1016/j.energy.2021.121087
中图分类号
O414.1 [热力学];
学科分类号
摘要
As the main source of heat loss of flat-plate solar air collectors (FPSACs), single glazing cover reduces the thermal performance of FPSAC. This situation becomes serious when the ambient temperature is low or the inlet temperature is high. A double glass cover with good thermal insulation is a good solution. This work aims to investigate the thermal performance of double glazing FPSAC at low ambient temperature and high inlet temperature. The thermal performance of four FPSACs with single glazing (Model 1), double glazing filled with air (Model 2), double glazing filled with argon (Model 3), and vacuum glazing (Model 4) as the glass cover at different ambient temperatures, different heat transfer air (HTA) inlet temperatures, and different HTA volume flow rates are studied and compared. Result demonstrates that Models 2, 3, and 4 have better thermal performance at low ambient temperature and high inlet tem-perature compared with Model 1. When the inlet temperature is 65 degrees C and ambient temperature is -10 degrees C, the thermal efficiencies of Models 2, 3, and 4 are 1.65, 1.72, and 2.29 times higher than that of Model 1, respectively. The efficiency factor and total heat loss coefficient of Model 4 are 0.62707 and 2.21745, respectively. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Selectively coated high efficiency glazing for solar-thermal flat-plate collectors
    Ehrmann, N.
    Reineke-Koch, R.
    THIN SOLID FILMS, 2012, 520 (12) : 4214 - 4218
  • [2] THERMAL PERFORMANCE OF FLAT-PLATE SOLAR COLLECTORS MANUFACTURED IN INDIA
    TIWARI, RC
    KUMAR, A
    GUPTA, SK
    SOOTHA, GD
    ENERGY CONVERSION AND MANAGEMENT, 1991, 31 (04) : 309 - 313
  • [3] Experimental analysis of thermal performance of evacuated tube and flat-plate solar air collectors at different air flow rates
    Kumar, Sanjeev
    Kumar, Ashish
    Yadav, Avadhesh
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENGINEERING, 2015, 8 (4-5) : 280 - 293
  • [4] Thermal performance enhancement of flat-plate solar collectors by means of three different nanofluids
    Ziyadanogullari, N. Budak
    Yucel, H. L.
    Yildiz, C.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 8 : 55 - 65
  • [5] Thermal inertia of flat-plate solar collectors in different radiative regimes
    Soriga, Iuliana
    Badescu, Viorel
    ENERGY CONVERSION AND MANAGEMENT, 2016, 111 : 27 - 37
  • [6] Computational Evaluation of Thermal and Hydraulic Characteristics of Flat-Plate Solar Collector for Different Glazing Material
    Singh, Vibhooti Vaibhav
    Thakur, Jitendra
    Agarwal, Rahul
    Vyas, Gaurav
    Dondapati, Raja Sekhar
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (14) : 28211 - 28220
  • [7] Thermal performance testing of flat-plate collectors
    Rojas, D.
    Beermann, J.
    Klein, S. A.
    Reindl, D. T.
    SOLAR ENERGY, 2008, 82 (08) : 746 - 757
  • [8] DIFFERENT STRATEGIES FOR OPERATION OF FLAT-PLATE SOLAR COLLECTORS
    ZAMFIR, E
    BADESCU, V
    ENERGY, 1994, 19 (12) : 1245 - 1254
  • [9] ANALYSIS OF THE TOP HEAT-LOSS FACTOR OF FLAT-PLATE SOLAR COLLECTORS WITH SINGLE AND DOUBLE GLAZING
    SAMDARSHI, SK
    MULLICK, SC
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1990, 14 (09) : 975 - 990
  • [10] Test Method to Measure Thermal Performance of Flat-plate Solar Collectors.
    Salvador, Franco
    Termotecnica Milano, 1979, 33 (08): : 464 - 472