Laboratory Evaluation to Reduce Respirable Crystalline Silica Dust When Cutting Concrete Roofing Tiles Using a Masonry Saw

被引:8
|
作者
Carlo, Rebecca V. [1 ]
Sheehy, John [2 ]
Feng, H. Amy [2 ]
Sieber, William K. [3 ]
机构
[1] ICU Environm Hlth & Safety, Houston, TX USA
[2] NIOSH DART, Cincinnati, OH 45226 USA
[3] NIOSH, Div Surveillance Hazard Evaluat & Field Studies, Cincinnati, OH 45226 USA
关键词
construction; engineering controls; masonry saw table; occupational health; CONSTRUCTION-INDUSTRY; EXPOSURE;
D O I
10.1080/15459620903579695
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Respirable crystalline silica dust exposure in residential roofers is a recognized hazard resulting from cutting concrete roofing tiles. Roofers cutting tiles using masonry saws can be exposed to high concentrations of respirable dust. Silica exposures remain a serious threat for nearly two million U. S. construction workers. Although it is well established that respiratory diseases associated with exposure to silica dust are preventable, they continue to occur and cause disability or death. The effectiveness of both a commercially available local exhaust ventilation (LEV) system and a water suppression system in reducing silica dust was evaluated separately. The LEV system exhausted 0.24, 0.13, or 0.12 m(3)/sec of dust laden air, while the water suppression system supplied 0.13, 0.06, 0.03, or 0.02 L/sec of water to the saw blade. Using a randomized block design, implemented under laboratory conditions, the aforementioned conditions were evaluated independently on two types of concrete roofing tiles (s-shape and flat) using the same saw and blade. Each engineering control (LEV or water suppression) was replicated eight times, or four times for each type of tile. Analysis of variance was performed by comparing the mean airborne respirable dust concentrations generated during each run and engineering control treatment. The use of water controls and ventilation controls compared with the "no control" treatment resulted in a statistically significant (p < 0.05) reduction of mean respirable dust concentrations generated per tile cut. The percent reduction for respirable dust concentrations was 99% for the water control and 91% for the LEV. Results suggest that water is an effective method for reducing crystalline silica exposures. However, water damage potential, surface discolorations, cleanup, slip hazards, and other requirements may make the use of water problematic in many situations. Concerns with implementing an LEV system to control silica dust exposures include sufficient capture velocity, additional weight of the saw with the LEV system, electricity connections, and cost of air handling unit.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 4 条
  • [1] Evaluation of Engineering Controls at Bagging Operations to Reduce Exposures to Respirable Crystalline Silica Dust
    A. Kyle Louk
    Justin R. Patts
    Emily J. Haas
    Andrew B. Cecala
    Mining, Metallurgy & Exploration, 2020, 37 : 1055 - 1064
  • [2] Evaluation of Engineering Controls at Bagging Operations to Reduce Exposures to Respirable Crystalline Silica Dust
    Louk, A. Kyle
    Patts, Justin R.
    Haas, Emily J.
    Cecala, Andrew B.
    MINING METALLURGY & EXPLORATION, 2020, 37 (04) : 1055 - 1064
  • [3] Evaluation of Cut-Off Saw Exposure Control Methods for Respirable Dust and Crystalline Silica in Roadway Construction
    Middaugh, Beauregard
    Hubbard, Bryan
    Zimmerman, Neil
    McGlothlin, James
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2012, 9 (03) : 157 - 165
  • [4] Respirable crystalline silica dust exposure during concrete finishing (grinding) using hand-held grinders in the construction industry
    Akbar-Khanzadeh, F
    Brillhart, RL
    ANNALS OF OCCUPATIONAL HYGIENE, 2002, 46 (03): : 341 - 346