Validation of a step detection Algorithm during straight Walking and turning in Patients with Parkinson's disease and older Adults Using an Inertial Measurement Unit at the Lower Back

被引:80
|
作者
Pham, Minh H. [1 ,2 ]
Elshehabi, Morad [1 ,3 ]
Haertner, Linda [3 ,4 ]
Del Din, Silvia [5 ]
Srulijes, Karin [6 ]
Heger, Tanja [3 ,4 ]
Synofzik, Matthis [3 ,4 ]
Hobert, Markus A. [1 ,3 ]
Faber, Gert S. [7 ]
Hansen, Clint [1 ]
Salkovic, Dina [3 ]
Ferreira, Joaquim J. [8 ,9 ]
Berg, Daniela [1 ,3 ]
Sanchez-Ferro, Alvaro [10 ,11 ]
van Dieen, Jaap H. [7 ]
Becker, Clemens [6 ]
Rochester, Lynn [5 ,12 ]
Schmidt, Gerhard [2 ]
Maetzler, Walter [1 ,3 ]
机构
[1] Univ Kiel, Dept Neurol, Kiel, Germany
[2] Univ Kiel, Digital Signal Proc & Syst Theory, Fac Engn, Kiel, Germany
[3] Univ Tubingen, Hertie Inst Clin Brain Res HIH, Dept Neurodegenerat, Ctr Neurol, Tubingen, Germany
[4] German Ctr Neurodegenerat Dis, DZNE, Tubingen, Germany
[5] Newcastle Univ, Inst Neurosci, Inst Ageing, Clin Ageing Res Unit, Campus Ageing & Vital, Newcastle Upon Tyne, Tyne & Wear, England
[6] Robert Bosch Krankenhaus, Dept Clin Gerontol, Stuttgart, Germany
[7] Vrije Univ Amsterdam, MOVE Res Inst Amsterdam, Dept Human Movement Sci, Amsterdam, Netherlands
[8] Inst Med Mol, Clin Pharmacol Unit, Lisbon, Portugal
[9] Univ Lisbon, Lab Clin Pharmacol & Therapeut, Fac Med, Lisbon, Portugal
[10] Hosp Univ HM Puerta Sur, HM CINAC, Madrid, Spain
[11] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[12] Newcastle Upon Tyne Hosp NHS Fdn Trust, Newcastle Upon Tyne, Tyne & Wear, England
来源
FRONTIERS IN NEUROLOGY | 2017年 / 8卷
基金
欧盟地平线“2020”; 英国惠康基金;
关键词
accelerometer; gait analysis; home-like activities; older adults; Parkinson's disease; turning; WEARABLE SENSORS; GAIT STABILITY; CLINICAL VIEW; FALL RISK; ACCELEROMETER; ASSOCIATION; PARAMETERS; IMPACT;
D O I
10.3389/fneur.2017.00457
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction: Inertial measurement units (IMUs) positioned on various body locations allow detailed gait analysis even under unconstrained conditions. From a medical perspective, the assessment of vulnerable populations is of particular relevance, especially in the daily-life environment. Gait analysis algorithms need thorough validation, as many chronic diseases show specific and even unique gait patterns. The aim of this study was therefore to validate an acceleration-based step detection algorithm for patients with Parkinson's disease (PD) and older adults in both a lab-based and home-like environment. Methods: In this prospective observational study, data were captured from a single 6-degrees of freedom IMU (APDM) (3DOF accelerometer and 3DOF gyroscope) worn on the lower back. Detection of heel strike (HS) and toe off (TO) on a treadmill was validated against an optoelectronic system (Vicon) (11 PD patients and 12 older adults). A second independent validation study in the home-like environment was performed against video observation (20 PD patients and 12 older adults) and included step counting during turning and non-turning, defined with a previously published algorithm. Results: A continuous wavelet transform (cwt)-based algorithm was developed for step detection with very high agreement with the optoelectronic system. HS detection inPD patients/older adults, respectively, reached 99/99% accuracy. Similar results were obtained for TO (99/100%). In HS detection, Bland-Altman plots showed a mean difference of 0.002 s [95% confidence interval (CI) -0.09 to 0.10] between the algorithm and the optoelectronic system. The Bland-Altman plot for TO detection showed mean differences of 0.00 s (95% CI -0.12 to 0.12). In the home-like assessment, the algorithm for detection of occurrence of steps during turning reached 90% (PD patients)/90% (older adults) sensitivity, 83/88% specificity, and 88/89% accuracy. The detection ofsteps during non-turning phases reached 91/91% sensitivity, 90/90% specificity, and 91/91% accuracy. Conclusion: This cwt-based algorithm for step detection measured at the lower back is in high agreement with the optoelectronic system in both PD patients and older adults. This approach and algorithm thus could provide a valuable tool for future research on home-based gait analysis in these vulnerable cohorts.
引用
收藏
页数:9
相关论文
共 19 条
  • [1] Algorithm for Turning Detection and Analysis Validated under Home-Like Conditions in Patients with Parkinson's Disease and Older Adults using a 6 Degree-of-Freedom Inertial Measurement Unit at the Lower Back
    Pham, Minh H.
    Elshehabi, Morad
    Haertner, Linda
    Heger, Tanja
    Hobert, Markus A.
    Faber, Gert S.
    Salkovic, Dina
    Ferreira, Joaquim J.
    Berg, Daniela
    Sanchez-Ferro, Alvaro
    van Dieen, Jaap H.
    Maetzler, Walter
    FRONTIERS IN NEUROLOGY, 2017, 8
  • [2] Validation of IMU-based gait event detection during curved walking and turning in older adults and Parkinson’s Disease patients
    Robbin Romijnders
    Elke Warmerdam
    Clint Hansen
    Julius Welzel
    Gerhard Schmidt
    Walter Maetzler
    Journal of NeuroEngineering and Rehabilitation, 18
  • [3] Validation of IMU-based gait event detection during curved walking and turning in older adults and Parkinson's Disease patients
    Romijnders, Robbin
    Warmerdam, Elke
    Hansen, Clint
    Welzel, Julius
    Schmidt, Gerhard
    Maetzler, Walter
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2021, 18 (01)
  • [4] Walking parameters of older adults from a lower back inertial measurement unit, a 6-year longitudinal observational study
    Elshehabi, Morad
    Del Din, Silvia
    Hobert, Markus A.
    Warmerdam, Elke
    Sunkel, Ulrike
    Schmitz-Hubsch, Tanja
    Behncke, Lisa Marie
    Heinzel, Sebastian
    Brockmann, Kathrin
    Metzger, Florian G.
    Schlenstedt, Christian
    Rochester, Lynn
    Hansen, Clint
    Berg, Daniela
    Maetzler, Walter
    FRONTIERS IN AGING NEUROSCIENCE, 2022, 14
  • [5] Turning Detection During Gait: Algorithm Validation and Influence of Sensor Location and Turning Characteristics in the Classification of Parkinson's Disease
    Rehman, Rana Zia Ur
    Klocke, Philipp
    Hryniv, Sofia
    Galna, Brook
    Rochester, Lynn
    Del Din, Silvia
    Alcock, Lisa
    SENSORS, 2020, 20 (18) : 1 - 24
  • [6] Validation of fNIRS measurement of executive demand during walking with and without dual-task in younger and older adults and people with Parkinson's disease
    Kvist, Alexander
    Bezuidenhout, Lucian
    Johansson, Hanna
    Albrecht, Franziska
    Conradsson, David Moulaee
    Franzen, Erika
    NEUROIMAGE-CLINICAL, 2024, 43
  • [7] Validity of shoe-type inertial measurement units for Parkinson's disease patients during treadmill walking
    Lee, Myeounggon
    Youm, Changhong
    Jeon, Jeanhong
    Cheon, Sang-Myung
    Park, Hwayoung
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2018, 15
  • [8] Validity of shoe-type inertial measurement units for Parkinson’s disease patients during treadmill walking
    Myeounggon Lee
    Changhong Youm
    Jeanhong Jeon
    Sang-Myung Cheon
    Hwayoung Park
    Journal of NeuroEngineering and Rehabilitation, 15
  • [9] Validation of a Lower Back "Wearable"-Based Sit-to-Stand and Stand-to-Sit Algorithm for Patients With Parkinson's Disease and Older Adults in a Home-Like Environment
    Pham, Minh H.
    Warmerdam, Elke
    Elshehabi, Morad
    Schlenstedt, Christian
    Bergeest, Lu-Marie
    Heller, Maren
    Haertner, Linda
    Ferreira, Joaquim J.
    Berg, Daniela
    Schmidt, Gerhard
    Hansen, Clint
    Maetzler, Walter
    FRONTIERS IN NEUROLOGY, 2018, 9
  • [10] Validation of a Spatiotemporal Gait Model Using Inertial Measurement Units for Early-Stage Parkinson's Disease Detection During Turns
    Yang, Yifan
    Chen, Lei
    Pang, Jun
    Huang, Xiayu
    Meng, Lin
    Ming, Dong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (12) : 3591 - 3600