Effective Length of Reinforced Concrete Columns in Braced Frames

被引:4
|
作者
Tikka, Timo K. [1 ]
Mirza, S. Ali [2 ]
机构
[1] Stantec Consulting, North Bay, ON P1B 2Y5, Canada
[2] Lakehead Univ, Thunder Bay, ON P7B 5E1, Canada
关键词
braced frames; building codes; columns (supports); concrete structures; effective length; reinforced concrete; slenderness; structural design; EQUATION;
D O I
10.1007/s40069-014-0070-7
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The American Concrete Institute (ACI) 318-11 permits the use of the moment magnifier method for computing the design ultimate strength of slender reinforced concrete columns that are part of braced frames. This computed strength is influenced by the column effective length factor K, the equivalent uniform bending moment diagram factor Cm and the effective flexural stiffness EI among other factors. For this study, 2,960 simple braced frames subjected to short-term loads were simulated to investigate the effect of using different methods of calculating the effective length factor K when computing the strength of columns in these frames. The theoretically computed column ultimate strengths were compared to the ultimate strengths of the same columns computed from the ACI moment magnifier method using different combinations of equations for K and EI. This study shows that for computing the column ultimate strength, the current practice of using the Jackson-Moreland Alignment Chart is the most accurate method for determining the effective length factor. The study also shows that for computing the column ultimate strength, the accuracy of the moment magnifier method can be further improved by replacing the current ACI equation for EI with a nonlinear equation for EI that includes variables affecting the column stiffness and proposed in an earlier investigation.
引用
收藏
页码:99 / 116
页数:18
相关论文
共 50 条
  • [1] Effective Length of Reinforced Concrete Columns in Braced Frames
    Timo K. Tikka
    S. Ali Mirza
    International Journal of Concrete Structures and Materials, 2014, 8 : 99 - 116
  • [2] Effective length factor for columns in braced frames
    Duan, Lian
    Chen, Wai-Fah
    Journal of structural engineering New York, N.Y., 1988, 114 (10): : 2357 - 2370
  • [3] EFFECTIVE LENGTH FACTOR FOR COLUMNS IN BRACED FRAMES
    DUAN, L
    CHEN, WF
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1988, 114 (10): : 2357 - 2370
  • [4] Effective length factor of columns in flexibly jointed and braced frames
    Kishi, N
    Chen, WF
    Goto, Y
    Komuro, M
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1998, 47 (1-2) : 93 - 118
  • [5] Effective length factor for columns in braced frames considering axial forces on restraining members
    Mahini, MR
    Seyyedian, H
    STRUCTURAL ENGINEERING AND MECHANICS, 2006, 22 (06) : 685 - 700
  • [6] EVALUATION OF EFFECTIVE LENGTH FACTORS IN BRACED FRAMES
    FRASER, DJ
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1983, 10 (01) : 18 - 26
  • [7] Inelastic Effective Length Factor of Nonsway Reinforced Concrete Columns
    Bendito, A.
    Romero, M. L.
    Bonet, J. L.
    Miguel, P. F.
    Fernandez, M. A.
    JOURNAL OF STRUCTURAL ENGINEERING, 2009, 135 (09) : 1034 - 1039
  • [8] A new method for determining the effective length factor of columns in partially braced frames on elastic supports
    Slimani, Adel
    Belaid, Toufik
    Saidani, Messaou
    Ammari, Fatiha
    Adman, Redouane
    STRUCTURAL ENGINEERING AND MECHANICS, 2023, 85 (06) : 825 - 835
  • [9] SEISMIC RESPONSE OF REINFORCED CONCRETE BRACED FRAMES.
    Kapur, V.
    Jain, Ashok
    Indian Concrete Journal, 1982, 56 (09): : 242 - 252
  • [10] EFFECTIVE LENGTH OF COLUMNS IN UNBRACED FRAMES
    GOGATE, AB
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1971, 8 (03): : 110 - &