Determination of cannabinoids in water and human saliva by solid-phase microextraction and quadrupole ion trap gas chromatography mass spectrometry

被引:55
|
作者
Hall, BJ [1 ]
Satterfield-Doerr, M [1 ]
Parikh, AR [1 ]
Brodbelt, JS [1 ]
机构
[1] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
关键词
D O I
10.1021/ac971228g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-phase microextraction (SPME) is applied to the determination of cannabidiol, Delta(8)-tetrahydrocannabinol (Delta(8)THC), Delta(9)-tetrahydrocannabinol (Delta(9)-THC), and cannabinol in pure water and human saliva. The inherent extraction behavior of the cannabinoids in pure water is evaluated along with optimization of the method in human saliva. The commercially available poly(dimethylsiloxane) (PDMS) SPME fibers were found to be the best class for the cannabinoid analysis. Partition coefficients were found to be extremely large for all of the cannabinoids (log K > 4.0). Equilibrium times for the 7- and 30-mu m PDMS fibers were 50 and 240 min, respectively. A shorter extraction time of 10 min with the 30-mu m PDMS fiber may be used for multiple extractions from the same vial, thus conserving the sample necessary for analysis and speeding up the total analysis time. Recoveries for the cannabinoids ire saliva, relative to pure water, were dramatically improved by a method developed in our laboratory involving addition of glacial acetic acid to the sample vial prior to performing SPME. Using this method, recoveries relative to SPME in pure welter ranged from 21 to 47% depending on the cannabinoid. The linear range for spiked saliva samples was established at 5-500 ng/mL (r(2) > 0.994) with precisions between 11 and 20% RSD. The ultimate level of detection by SPME for the cannabinoids in saliva was 1.0 ng/mL, with signal-to-noise values of greater than or equal to 12. A saliva sample collected 30 min after marijuana smoking was subject to SPME and traditional liquid-liquid extraction analysis, Internal standard quantitation results for Delta(9)-THC by both methods yielded comparable results, indicating that the SPME method of analysis is highly accurate and precise. The level of Delta(9)-THC by SPME was found to be 9.54 ng/mL for the saliva sample.
引用
收藏
页码:1788 / 1796
页数:9
相关论文
共 50 条
  • [1] Determination of barbiturates by solid-phase microextraction (SPME) and ion trap gas chromatography mass spectrometry
    Hall, BJ
    Brodbelt, JS
    JOURNAL OF CHROMATOGRAPHY A, 1997, 777 (02) : 275 - 282
  • [2] Determination of Aldehydes in Environmental Water by Solid-Phase Microextraction and Gas Chromatography-Ion Trap Mass Spectrometry
    Zhang, Yiming
    Zhao, Dong
    Wang, Bing
    Liang, Zhu
    Chen, Yi
    Meng, Bao
    Shang, Shuyong
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2015, 43 (03) : 344 - 356
  • [3] Solid-phase microextraction in the determination of methadone in human saliva by gas chromatography-mass spectrometry
    Lucas, ACD
    Bermejo, A
    Fernández, P
    Tabernero, MJ
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (02) : 93 - 96
  • [4] Headspace solid-phase microextraction and gas chromatography−mass spectrometry for determination of cannabinoids in human breast milk
    Gabriela de Oliveira Silveira
    Silvana Loddi
    Carolina Dizioli Rodrigues de Oliveira
    Alexandre Dias Zucoloto
    Ligia Veras Gimenez Fruchtengarten
    Mauricio Yonamine
    Forensic Toxicology, 2017, 35 : 125 - 132
  • [5] Headspace solid-phase microextraction and gas chromatography-mass spectrometry for determination of cannabinoids in human breast milk
    Silveira, Gabriela de Oliveira
    Loddi, Silvana
    Rodrigues de Oliveira, Carolina Dizioli
    Zucoloto, Alexandre Dias
    Gimenez Fruchtengarten, Ligia Veras
    Yonamine, Mauricio
    FORENSIC TOXICOLOGY, 2017, 35 (01) : 125 - 132
  • [6] Determination of gamma-hydroxybutyrate in water and human urine by solid phase microextraction-gas chromatography/quadrupole ion trap spectrometry
    Blair, S
    Song, M
    Hall, B
    Brodbelt, J
    JOURNAL OF FORENSIC SCIENCES, 2001, 46 (03) : 688 - 693
  • [7] Determination of frequently detected herbicides in water by solid-phase microextraction and gas chromatography coupled to ion-trap tandem mass spectrometry
    Perreau, Francois
    Einhorn, Jacques
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (05) : 1449 - 1456
  • [8] Determination of frequently detected herbicides in water by solid-phase microextraction and gas chromatography coupled to ion-trap tandem mass spectrometry
    François Perreau
    Jacques Einhorn
    Analytical and Bioanalytical Chemistry, 2006, 386 : 1449 - 1456
  • [9] Determination of midazolam in human plasma by solid-phase microextraction and gas chromatography/mass spectrometry
    Frison, G
    Tedeschi, L
    Maietti, S
    Ferrara, SD
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (24) : 2497 - 2501
  • [10] Solid-phase microextraction coupled with gas chromatography-ion trap mass spectrometry for the analysis of haloacetic acids in water
    Sarrión, MN
    Santos, FJ
    Galceran, MT
    JOURNAL OF CHROMATOGRAPHY A, 1999, 859 (02) : 159 - 171