Characterizing the Active Opening of the Eustachian Tube in a Hypobaric/Hyperbaric Pressure Chamber

被引:0
|
作者
Mikolajczak, Stefanie [1 ]
Meyer, Moritz Friedo [1 ]
Hahn, Moritz [2 ]
Korthaeuer, Christine [1 ]
Jumah, Masen Dirk [3 ]
Huettenbrink, Karl-Bernd [1 ]
Grosheva, Maria [1 ]
Luers, Jan Christoffer [1 ]
Beutner, Dirk [1 ]
机构
[1] Univ Cologne, Dept Otorhinolaryngol Head & Neck Surg, Villingen Schwenningen, Germany
[2] Univ Cologne, Inst Med Stat Informat & Epidemiol, Villingen Schwenningen, Germany
[3] Hosp Schwarzwald Baar Klinikum, Dept Otorhinolaryngol, Villingen Schwenningen, Germany
关键词
Active; Eustachian tube; Pressure chamber; Pressure equalization; MIDDLE-EAR MECHANICS; TUBOPLASTY; DYSFUNCTION; DILATION;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Active and passive opening of the Eustachian tube (ET) enables direct aeration of the middle ear and a pressure balance between middle ear and the ambient pressure. The aim of this study was to characterize standard values for the opening pressure (ETOP), the opening frequency (ETOF), and the opening duration (ETOD) for active tubal openings (Valsalva maneuver, swallowing) in healthy participants. Design/Participants: In a hypobaric/hyperbaric pressure chamber, 30 healthy participants (19 women, 11 men; mean age, 25.57 +/- 3.33 years) were exposed to a standardized profile of compression and decompression. The pressure values were recorded via continuous impedance measurement during the Valsalva maneuver and swallowing. Based on the data, standard curves were identified and the ETOP, ETOD, and ETOF were determined. Results: Recurring patterns of the pressure curve during active tube opening for the Valsalva maneuver and for active swallowing were characterized. The mean value for the Valsalva maneuver for ETOP was 41.21 +/- 17.38 mbar; for the ETOD, it was 2.65 +/- 1.87 seconds. In the active pressure compensation by swallowing, the mean value for the ETOP was 29.91 +/- 13.07 mbar; and for the ETOD, it was 0.82 +/- 0.53 seconds. Conclusion: Standard values for the opening pressure of the tube and the tube opening duration for active tubal openings (Valsalva maneuver, swallowing) were described, and typical curve gradients for healthy subjects could be shown. This is another step toward analyzing the function of the tube in compression and decompression.
引用
下载
收藏
页码:70 / 75
页数:6
相关论文
共 50 条
  • [1] Characterizing the Passive Opening of the Eustachian Tube in a Hypo-/hyperbaric Pressure Chamber
    Meyer, M. F.
    Mikolajczak, S.
    Luers, J. C.
    Lotfipour, S.
    Beutner, D.
    Jumah, M. D.
    LARYNGO-RHINO-OTOLOGIE, 2013, 92 (09) : 600 - 606
  • [2] Reliability of Eustachian tube function measurements in a hypobaric and hyperbaric pressure chamber
    Meyer, M. F.
    Jansen, S.
    Mordkovich, O.
    Huettenbrink, K. -B.
    Beutner, D.
    CLINICAL OTOLARYNGOLOGY, 2017, 42 (06) : 1343 - 1349
  • [3] Is there a difference between active opening of the Eustachian tube in a hypobaric surrounding compared to a hyperbaric surrounding?
    Mikolajczak, Stefanie
    Meyer, Moritz Friedo
    Felsch, Moritz
    Jumah, Masen Dirk
    Huettenbrink, Karl-Bernd
    Grosheva, Maria
    Luers, Jan-Christoffer
    Beutner, Dirk
    UNDERSEA AND HYPERBARIC MEDICINE, 2015, 42 (06) : 593 - 599
  • [4] Prospective study on the Eustachian tube function during Frenzel maneuver in a hypobaric/hyperbaric pressure chamber
    Philipp Wolber
    Moritz Friedo Meyer
    Kristijana Knesic
    Svenja Rink
    Stefanie Jansen
    Jens Peter Klussmann
    Maria Grosheva
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 1843 - 1850
  • [5] Prospective study on the Eustachian tube function during Frenzel maneuver in a hypobaric/hyperbaric pressure chamber
    Wolber, Philipp
    Meyer, Moritz Friedo
    Knesic, Kristijana
    Rink, Svenja
    Jansen, Stefanie
    Klussmann, Jens Peter
    Grosheva, Maria
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (04) : 1843 - 1850
  • [6] The pressure-equalizing function of the Eustachian tube. Evaluation in a hypo-/hyperbaric pressure chamber
    Jansen, S.
    Meyer, M. F.
    Huettenbrink, K. -B.
    Beutner, D.
    HNO, 2017, 65 (08) : 634 - 642
  • [7] DEFLATION OPENING PRESSURE OF THE EUSTACHIAN-TUBE
    COHEN, D
    AMERICAN JOURNAL OF OTOLOGY, 1989, 10 (02): : 138 - 141
  • [8] Concordance Analysis of the Pressure Chamber and Tubomanometer According to Estève for the Determination of Eustachian Tube Opening Pressure
    Deuss, Eric
    Loeding, Katharina
    Breitrueck, Nils
    Lang, Stephan
    Klussmann, Jens Peter
    Jansen, Stefanie
    Meyer, Moritz Friedo
    OTOLOGY & NEUROTOLOGY, 2024, 45 (05) : e411 - e419
  • [9] The deflation (passive) opening pressure of the eustachian tube
    Cohen, David
    Perez, Ronen
    Peleg, Uri
    Raveh, David
    MEDITERRANEAN JOURNAL OF OTOLOGY, 2007, 3 (02): : 62 - 68
  • [10] The measurement of Eustachian tube function in a hyperbaric chamber using an ear canal microphone
    Fischer, Hans-Georg
    Koch, Andreas
    Kaehler, Wataru
    Pohl, Michael
    Pau, Hans-Wilhelm
    Zehlicke, Thorsten
    DIVING AND HYPERBARIC MEDICINE, 2016, 46 (01) : 33 - 37