Real-time in vitro measurement of denture-mucosa pressure distribution in a typical edentulous patient with and without implants: Development of a methodology

被引:1
|
作者
Paras, Alessandra [1 ]
Ma, Sunyoung [1 ]
Waddell, John Neil [1 ]
Choi, Joanne Jung Eun [1 ]
机构
[1] Univ Otago, Fac Dent, Sir John Walsh Res Inst, Dunedin, New Zealand
关键词
Complete denture; Implant overdenture; Pressure distribution; Oral mucosa; Edentulism; OVERDENTURES; BEHAVIOR; NUMBER;
D O I
10.1016/j.jmbbm.2021.104531
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: To measure the pressure distribution on the oral mucosa in vitro by comparing the pressure distributions under a complete denture and that of an implant overdenture. Materials and method: Anatomically accurate models and conventional Class I complete denture (CD) were produced and subjected to cyclic loading using a 100 N vertical centric and unilateral masticatory load with the universal testing machine (Instron 3369). Four miniature pressure sensors were positioned at four different locations in the intaglio surface of the denture and recorded pressure at 100 Hz frequency measured during a 10cycle load at 1 Hz. Testing was repeated in different clinical combinations; CD vs. single implant overdentures (1IOD), CD vs. two, three and four implant overdentures (2-IOD, 3-IOD vs. 4-IOD). The pressure profile (kPa) of complete dentures were measured and compared to the implant overdenture combinations. Collected data was statically analysed using SPSS and one-way analysis of variance. Results: The highest mean pressure was observed in CD group, with the mean mandible buccal ridge pressure value of 212.82 kPa +/- 136.9 due to its surface area. There were no statistically significant differences between the group combinations (p = 0.146) but between various locations in the mean pressure recorded across the five denture/overdenture combinations. Conclusion: CD experienced large pressure values on mandibular denture. 1-IOD demonstrated the most pressure in comparison to CD where with an increase in the number of implants used, it transformed the denture from being pure-borne mucosa to an implant overdenture, providing support and distributing the pressure amongst the implants.
引用
收藏
页数:10
相关论文
共 11 条
  • [1] Denture-Mucosa Pressure Distribution and Pressure-Pain Threshold in In Vivo, In Vitro and In Silico Studies: A Literature Review
    Paras, Alessandra
    Ma, Sunyoung
    Waddell, John Neil
    Choi, Joanne Jung Eun
    ORAL, 2022, 2 (01): : 112 - 125
  • [2] Real-time measurement of blood pressure with Nexfin in a patient with thalidomide-related phocomelia
    Earle, Rosie
    Vaghadia, Himat
    Shanahan, Enda
    Tang, Raymond
    Sawka, Andrew
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 34 : 244 - 246
  • [3] Development of a Real-time Analyzer for Peripheral Venous Evaluation during Blood Pressure Measurement
    Kashihara, K.
    2014 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2014, : 88 - 92
  • [4] Infrared tomography: Data distribution system and software development for real-time velocity measurement
    Rahim, Ruzairi Abdul
    Fea, Pang Jon
    San, Chan Kok
    Chen, Leong Lai
    Sulaiman, S.
    Manaf, M. S. Abdul
    ISA TRANSACTIONS, 2007, 46 (02) : 131 - 145
  • [5] Field-Oriented Methodology for Real-Time Pressure Control to Reduce Leakage in Water Distribution Networks
    Campisano, A.
    Modica, C.
    Reitano, S.
    Ugarelli, R.
    Bagherian, S.
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2016, 142 (12)
  • [6] A method for continuous real-time measurement of the pressure exerted by the shaft of a colonoscope upon the bowel wall: An in vitro evaluation
    Dogramadzi, S
    Allen, C
    Bell, GD
    Rowland, RS
    GUT, 2000, 46 : A30 - A30
  • [7] Development of Real-Time Cuffless Blood Pressure Measurement Systems with ECG Electrodes and a Microphone Using Pulse Transit Time (PTT)
    Choi, Jingyu
    Kang, Younghwan
    Park, Jaesoon
    Joung, Yeunho
    Koo, Chiwan
    SENSORS, 2023, 23 (03)
  • [8] Real-Time Measurement of the Size Distribution of Diesel Exhaust Particles using a Portable 4-stage Electrical Low Pressure Impactor
    Park, Dongho
    Choi, Nak-Kyoung
    Lee, Sang-Gu
    Hwang, Jungho
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2009, 26 (04) : 179 - 186
  • [9] Migration behavior of space charge packet researched by using electron beam irradiation and real-time space charge distribution measurement in piezo-pressure wave method
    Pan, Jia-Ping
    Zhang, Ye-Wen
    Li, Jun
    Lue, Tian-Hua
    Zheng, Fei-Hu
    ACTA PHYSICA SINICA, 2024, 73 (02)
  • [10] Development and Evaluation of "The Delta Plus-Minus Even Distribution Check": A Novel Patient-Based Real-Time Quality Control Method for Laboratory Tests
    Hatanaka, Noriko
    Yamamoto, Yoshikazu
    Shiozaki, Yuya
    Kuramura, Eiji
    Nagai, Naoharu
    Kondo, Akira
    Kamioka, Mikio
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2024, 9 (02): : 316 - 328