Performance mapping of the R744 ejectors for refrigeration and air conditioning supermarket application: A hybrid reduced-order model

被引:31
|
作者
Haida, Michal [1 ]
Smolka, Jacek [1 ]
Hafner, Armin [2 ]
Ostrowski, Ziemowit [1 ]
Palacz, Michal [1 ]
Madsen, Kenneth B. [3 ]
Foersterling, Sven [4 ]
Nowak, Andrzej J. [1 ]
Banasiak, Krzysztof [5 ]
机构
[1] Silesian Tech Univ, Inst Thermal Technol, Konarskiego 22, PL-44100 Gliwice, Poland
[2] NTNU Dept Energy & Proc Engn, Kolbjorn Hejes Vei 1d, N-7465 Trondheim, Norway
[3] Danfoss AS, Jegstrupvej 3, DK-8361 Hasselager, Denmark
[4] TLK Thermo GmbH, D-38106 Braunschweig, Germany
[5] SINTEF Energy, Kolbjorn Hejes Vei 1d, N-7465 Trondheim, Norway
关键词
Carbon dioxide; Refrigeration system; Air-conditioning; Two-phase ejector; Reduced-order model; Performance mapping; CO2; HEAT-PUMP; MULTI-EJECTOR; 2-PHASE EJECTOR; SHAPE OPTIMIZATION; GEOMETRY EJECTORS; SYSTEM; EXPANSION; MODULE;
D O I
10.1016/j.energy.2018.04.088
中图分类号
O414.1 [热力学];
学科分类号
摘要
The continuous derivation of the ambient temperature and cooling demand in CO2 refrigeration and air-conditioning systems equipped with multi-ejector modules for supermarkets requires the analysis of the fixed ejector utilisation in a very wide range of the operational envelope. Therefore, performance mapping of the four R744 ejectors installed in the multi-ejector pack was performed. The investigations of a single ejector's work were performed based on the proposed hybrid reduced-order model to predict the performance of each ejector under arbitrary operating conditions. The proposed model was validated and generated by use of the experimental data together with the computational fluid dynamic model results. The ejector efficiency mapping indicated the area of the best ejector performance in the range from approximately 50 bar-100 bar. The mass entrainment ratio of all four ejectors was presented for different ambient temperatures and the pressure lift. An area of the mass entrainment ratio greater than 0.3 was obtained by each ejector at ambient temperature above approximately 15 degrees C for pressure lift below 10 bar. The approximation functions of the ejector pressure lift in terms of the ambient temperature for air-conditioning operating conditions to reach the best efficiency of each ejector are proposed. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:933 / 948
页数:16
相关论文
共 23 条
  • [1] PERFORMANCE EVALUTATION OF A R744 BOOSTER SYSTEM FOR SUPERMARKET REFRIGERATION, HEATING AND DHW
    Polzot, Alessio
    Gullo, Paride
    D'Agaro, Paola
    Cortella, Giovanni
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 154 - 161
  • [2] THE R744 MULTI-EJECTOR HYBRID CFD AND EXPERIMENTALLY-BASED REDUCED-ORDER MODEL
    Haida, Michal
    Smolka, Jacek
    Hafner, Armin
    Palacz, Michal
    Ostrowski, Ziemowit
    Madsen, Kenneth B.
    Foersterling, Sven
    Nowak, Andrzej J.
    Banasiak, Krzysztof
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 516 - 523
  • [3] Energy and environmental investigation of R744 all-in-one configurations for refrigeration and heating/air conditioning needs of a supermarket
    Tsimpoukis, Dimitrios
    Syngounas, Evangelos
    Petsanas, Dimitrios
    Mitsopoulos, Georgios
    Anagnostatos, Stavros
    Bellos, Evangelos
    Tzivanidis, Christos
    Vrachopoulos, Michail Gr.
    JOURNAL OF CLEANER PRODUCTION, 2021, 279
  • [4] Performance operation of liquid ejectors for a R744 integrated multi-ejector supermarket system using a hybrid ROW
    Haida, Michal
    Smolka, Jacek
    Hafner, Armin
    Palacz, Michal
    Ostrowski, Ziemowit
    Bodys, Jakub
    Kriezi, Ekaterini K.
    Foersterling, Sven
    Nowak, Andrzej J.
    Banasiak, Krzysztof
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 110 : 58 - 74
  • [5] Performance Analysis of an R744 Supermarket Refrigeration System Integrated with an Organic Rankine Cycle
    Sengupta, Ayan
    Gullo, Paride
    Dasgupta, Mani Sankar
    Khorshidi, Vahid
    ENERGIES, 2023, 16 (22)
  • [6] Energy and environmental performance assessment of R744 booster supermarket refrigeration systems operating in warm climates
    Gullo, Paride
    Elmegaard, Brian
    Cortella, Giovanni
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 64 : 61 - 79
  • [7] An Object-Oriented R744 Two-Phase Ejector Reduced-Order Model for Dynamic Simulations
    Haida, Michal
    Fingas, Rafal
    Szwajnoch, Wojciech
    Smolka, Jacek
    Palacz, Michal
    Bodys, Jakub
    Nowak, Andrzej J.
    ENERGIES, 2019, 12 (07)
  • [8] Model Based Sensor System for Temperature Measurement in R744 Air Conditioning Systems
    Reitz, Sven
    Schroth, Andreas
    Schneider, Peter
    DTIP 2008: SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS, 2008, : 171 - +
  • [9] Performance and economic evaluation of CO2 (R744) air conditioning system driven by compressed air engine
    Wang, Lei
    Zhu, Shi-Liang
    Zhang, Xin-Rong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 135 : 189 - 197
  • [10] Coupling Effect of Air Flow Rate and Operating Conditions on the Performance of Electric Vehicle R744 Air Conditioning System
    Wang, Anci
    Fang, Jianmin
    Yin, Xiang
    Song, Yulong
    Cao, Feng
    Gullo, Paride
    APPLIED SCIENCES-BASEL, 2021, 11 (11):