An assessment of biomedical CoCrMo alloy fabricated by direct metal laser sintering technique for implant applications

被引:42
|
作者
Girao, Daniel de Castro [1 ]
Beres, Miloslav [1 ,2 ]
Jardini, Andre Luiz [2 ]
Maciel Filho, Rubens [2 ]
Silva, Cleiton Carvalho [1 ]
de Siervo, Abner [3 ]
Gomes de Abreu, Hamilton Ferreira [1 ]
Araujo, Walney Silva [1 ]
机构
[1] Univ Fed Ceara, Dept Met & Mat Engn, BR-60440900 Fortaleza, CE, Brazil
[2] Univ Estadual Campinas, Fac Chem Engn, BIOFABRIS Natl Inst Sci & Technol Biomfg, BR-13081970 Campinas, SP, Brazil
[3] Univ Estadual Campinas, Inst Phys Gleb Wataghin, BR-13083859 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
CoCrMo alloy; Corrosion resistance; Simulated body fluids; Additive manufacturing; Direct metal laser sintering; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; CORROSION BEHAVIOR; BIOLOGICAL ENVIRONMENTS; TI-6AL-4V ALLOYS; SERUM-ALBUMIN; AISI; 316L; MICROSTRUCTURE; WEAR; TRANSFORMATION; CO-28CR-6MO;
D O I
10.1016/j.msec.2019.110305
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
CoCrMo alloys have been used for several decades in implantable devices due to their favourable mechanical properties, low wear rate in addition to good biocompatibility and high corrosion resistance. These alloys are conventionally produced via casting and/or forging route, however additive manufacturing techniques being recently employed in their fabrication. In this work, CoCrMo samples were produced by direct metal laser sintering additive manufacturing process. The microstructure and surface composition were examined employing scanning electron microscopy, X-ray diffraction and X-ray photoelectron spectroscopy (XPS). The corrosion resistance was measured in 0.14 M sodium chloride solution and in phosphate buffered solution (PBS) both with and without addition of albumin at pH 7.4 and 37 degrees C. For this, potentiodynamic tests in addition to electrochemical impedance spectroscopy were employed. The studied CoCrMo alloy exhibits a good corrosion resistance in solutions tested being the highest in PBS solution without albumin addition. The XPS analysis showed that the passive film composition and its thickness are not modified by the adsorbed layer. Microstructural analysis revealed occurrence of strain-induced martensitic transformation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Characterization of CoCrMo alloy fabricated by sintering for biomedical materials
    J. Lemus-Ruiz
    A. M. Garcia-Carrillo
    J. L. Cabezas-Villa
    L. Olmos
    MRS Advances, 2023, 8 : 1107 - 1111
  • [2] Characterization of CoCrMo alloy fabricated by sintering for biomedical materials
    Lemus-Ruiz, J.
    Garcia-Carrillo, A. M.
    Cabezas-Villa, J. L.
    Olmos, L.
    MRS ADVANCES, 2023, 8 (20) : 1107 - 1111
  • [3] Evaluation of Compression, Wear and Electrochemical Behavior of CoCrMo Alloy Samples Fabricated with Direct Metal Laser Sintering
    Seshagirirao, D. V.
    Raju, S.
    Mantrala, Kedar Mallik
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2023, 32 (17) : 7633 - 7639
  • [4] Evaluation of Compression, Wear and Electrochemical Behavior of CoCrMo Alloy Samples Fabricated with Direct Metal Laser Sintering
    D. V. Seshagirirao
    S. Raju
    Kedar Mallik Mantrala
    Journal of Materials Engineering and Performance, 2023, 32 : 7633 - 7639
  • [5] Mechanical and phase transformation behaviour of biomedical Co-Cr-Mo alloy fabricated by direct metal laser sintering
    Beres, M.
    Silva, C. C.
    Sarvezuk, P. W. C.
    Wu, L.
    Antunes, L. H. M.
    Jardini, A. L.
    Feitosa, A. L. M.
    Zilkova, J.
    de Abreu, H. F. G.
    Filho, R. M.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2018, 714 : 36 - 42
  • [6] Intergranular pitting corrosion of CoCrMo biomedical implant alloy
    Panigrahi, Pooja
    Liao, Yifeng
    Mathew, Mathew T.
    Fischer, Alfons
    Wimmer, Markus A.
    Jacobs, Joshua J.
    Marks, Laurence D.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2014, 102 (04) : 850 - 859
  • [7] Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique
    Dimitriadis, Konstantinos
    Spyropoulos, Konstantinos
    Papadopoulos, Triantafillos
    JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (01): : 25 - 31
  • [8] Selective Laser Melting of a CoCrMo alloy for biomedical applications: correlations between microstructure and process parameters
    Tonelli, L.
    Boromei, I
    Fortunato, A.
    Ceschini, L.
    METALLURGIA ITALIANA, 2019, 111 (06): : 41 - 47
  • [9] Direct Metal Laser Sintering New Possibilities in Biomedical Part Manufacturing
    Kotila, Juha
    Syvanen, Tatu
    Hanninen, Jouni
    Latikka, Maria
    Nyrhila, Olli
    PROGRESS IN POWDER METALLURGY, PTS 1 AND 2, 2007, 534-536 : 461 - +
  • [10] Corrosion resistance of direct metal laser sintering AlSiMg alloy
    Cabrini, M.
    Lorenzi, S.
    Pastore, T.
    Pellegrini, S.
    Pavese, M.
    Fino, P.
    Ambrosio, E. P.
    Calignano, F.
    Manfredi, D.
    SURFACE AND INTERFACE ANALYSIS, 2016, 48 (08) : 825 - 833