Comparison between DVR and SFCL for Fault Ride through Capability Improvement of Fixed-Speed Wind Generator

被引:0
|
作者
Abu Hussein, Ahmed [1 ]
Ali, Mohd. Hasan [1 ]
机构
[1] Univ Memphis, Dept Elect Engn & Comp Engn, Memphis, TN 38152 USA
来源
2014 IEEE PES T&D CONFERENCE AND EXPOSITION | 2014年
关键词
Balanced Faults; Dynamic Voltage Restorer (DVR); superconducting fault current limiter (SFCL); transient stability; wind generator; DYNAMIC VOLTAGE RESTORERS; CURRENT LIMITER; SYSTEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This Paper makes a comparison between the Superconductor Fault Current Limiter (SFCL) and Dynamic Voltage Restorer (DVR) in terms of fault ride through capability improvement of a fixed speed wind generator system. The performance, controller complexity, and cost are considered as criteria for comparison between the mentioned two devices. Simulations are performed using Matlab/Simulink software, where the tested system consists of one synchronous generator and one squirrel cage induction machine based wind generator, which feed an infinite bus through a double circuit transmission line. Simulation results show that both the DVR and SFCL perform well, however, the DVR has better fault ride through capability than the SFCL, and is more efficient in reducing the fluctuations of voltage, power, and speed of the wind generator. In addition, the DVR helps wind generators keep voltage sag within the grid code requirement with lower cost as compared to the SFCL.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Smart Loads for Improving the Fault-Ride-Through Capability of Fixed-Speed Wind Generators in Microgrids
    Yan, Shuo
    Wang, Ming-Hao
    Chen, Jie
    Hui, S. Y.
    IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (01) : 661 - 669
  • [2] Comparison of Different Methods for Fault Ride Through Ability of Fixed-Speed Wind Generation Systems
    Tian, Lei
    Wang, Tong
    Miao, Ya
    ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING, PTS 1-3, 2013, 278-280 : 1427 - 1431
  • [3] Fixed-Speed Wind Farm Operation Improvement by Using DVR Devices
    Gaztanaga, H.
    Etxeberria-Otadui, I.
    Bacha, S.
    Roye, D.
    2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 2679 - +
  • [4] Improving Fault Ride-Through Capability of Fixed-Speed Wind Turbine by Using Bridge-Type Fault Current Limiter
    Firouzi, M.
    Gharehpetian, G. B.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2013, 28 (02) : 361 - 369
  • [5] Low Voltage Ride Through Capability Enhancement of Fixed Speed Wind Generator
    Muyeen, S. M.
    Takahashi, R.
    Murata, T.
    Tamura, J.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 2411 - 2416
  • [6] Impact of fault ride-through requirements on fixed-speed wind turbine structural loads
    Hansen, Anca D.
    Cutululis, Nicolaos A.
    Markou, Helen
    Sorensen, Poul E.
    WIND ENERGY, 2011, 14 (01) : 1 - 11
  • [7] Comparison of Stabilization Methods for Fixed-Speed Wind Generator Systems
    Ali, Mohd Hasan
    Wu, Bin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (01) : 323 - 331
  • [8] Comparison Among Stabilization Methods of Fixed-Speed Wind Generator System
    Ali, Mohd. Hasan
    Wu, Bin
    2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 2927 - +
  • [9] Low voltage ride-through improvement for fixed-speed wind turbines based on full power converters
    Huang, W. (hwhuang@mail.iee.ac.cn), 2013, Automation of Electric Power Systems Press (37):
  • [10] Performance comparison of a Left Shunt UPQC and a Right Shunt UPQC applied to enhance fault-ride-through capability of a fixed speed wind generator
    Jayanti, N. G.
    Basu, Malabika
    Conlon, Michael F.
    Gaughan, Kevin
    2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, 2007, : 203 - 211