Thermal characteristics of a resurfaced condenser and evaporator closed two-phase thermosyphon

被引:82
|
作者
Rahimi, Masoud [1 ]
Asgary, Kayvan [1 ]
Jesri, Simin [2 ]
机构
[1] Razi Univ, Dept Chem Engn, CFD Res Ctr, Kermanshah, Iran
[2] Iranian Natl Gas Co Kermanshah Prov, Kermanshah, Iran
关键词
Energy recovery; Thermosyphon; Heat transfer; Performance; Resurfacing; HEAT-TRANSFER CHARACTERISTICS; NANOFLUIDS; SURFACE; FLUX; FLOW;
D O I
10.1016/j.icheatmasstransfer.2010.02.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper reports a study on the effect of the condenser and evaporator resurfacing on overall performance of a 1 m height closed two-phase thermosyphon. Water was used as working fluid with a fill ratio and operating pressure was 0.75 and 160 mbar, respectively. The thermosyphon performances for plain and modified thermosyphon were studied at 44 power inputs from 43 W to 668 W. The results show that by making the evaporator more hydrophilic and the condenser more hydrophobic, it will be possible to increase the average thermal performance by15.27% and decrease the thermal resistance by 2.35 times compared with the plain one. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:703 / 710
页数:8
相关论文
共 50 条
  • [1] Thermal performance enhancement in two-phase closed thermosyphon with sandblasted evaporator surface
    Kang, Sukkyung
    Lee, Seokjin
    Lee, Jungho
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [2] Effects of hydrophobic and superhydrophobic coatings of a condenser on the thermal performance of a two-phase closed thermosyphon
    Kim, Yeonghwan
    Kim, Jin Sub
    Shin, Dong Hwan
    Seo, Jin Hyeuk
    You, Seung M.
    Lee, Jungho
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 144
  • [3] Numerical investigations on the thermal performance of two-phase closed thermosyphon with extended condenser surface
    Liu, Zhao
    Zhao, Jin
    Wang, Chao
    Qin, Yangjun
    Wang, Yanbiao
    Liu, Chang
    [J]. HEAT AND MASS TRANSFER, 2023, 59 (03) : 377 - 392
  • [4] Effect of sintered microporous coating at the evaporator on the thermal performance of a two-phase closed thermosyphon
    Kim, Yeonghwan
    Shin, Dong Hwan
    Kim, Jin Sub
    You, Seung M.
    Lee, Jungho
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 131 : 1064 - 1074
  • [5] Numerical investigations on the thermal performance of two-phase closed thermosyphon with extended condenser surface
    Zhao Liu
    Jin Zhao
    Chao Wang
    Yangjun Qin
    Yanbiao Wang
    Chang Liu
    [J]. Heat and Mass Transfer, 2023, 59 : 377 - 392
  • [6] Theoretical investigation on the flooding limit in condenser of a two-phase closed thermosyphon
    Institute of Refrigeration and Cryogenic Engineering, Zhejiang University, Hangzhou 310027, China
    [J]. Kung Cheng Je Wu Li Hsueh Pao, 2008, 6 (1028-1030):
  • [7] Heat Transfer Characteristics inside an Evaporator of a Two-Phase Closed Loop Thermosyphon with Saw Tooth Ribbed Evaporator Surface
    Mahmood, S. L.
    Bagha, N.
    Akhanda, M. A. R.
    Islam, A. K. M. S.
    [J]. ADVANCED DESIGN AND MANUFACTURE TO GAIN A COMPETITIVE EDGE: NEW MANUFACTURING TECHNIQUES AND THEIR ROLE IN IMPROVING ENTERPRISE PERFORMANCE, 2008, : 111 - 120
  • [8] Heat transfer characteristics in a closed two-phase thermosyphon
    [J]. 1600, Publ by Hemisphere Publ Corp, New York, NY, USA
  • [9] Heat transfer characteristics of a two-phase closed thermosyphon
    Noie, SH
    [J]. APPLIED THERMAL ENGINEERING, 2005, 25 (04) : 495 - 506
  • [10] Heat transfer characteristics in a condenser of closed two-phase thermosyphon: Effect of entrainment on heat transfer deterioration
    Hashimoto, Hiroyuki
    Kaminaga, Fumito