Geometric accuracy of magnetic resonance imaging-derived virtual 3-dimensional bone surface models of the mandible in comparison to computed tomography and cone beam computed tomography: A porcine cadaver study

被引:10
|
作者
Probst, Florian Andreas [1 ]
Burian, Egon [2 ]
Malenova, Yoana [1 ]
Lyutskanova, Plamena [1 ]
Stumbaum, Maria Juliane [3 ]
Ritschl, Lucas Maximilian [4 ]
Kronthaler, Sophia [5 ]
Karampinos, Dimitrios [5 ]
Probst, Monika [2 ]
机构
[1] LMU Munchen, Univ Hosp, Dept Oral & Maxillofacial Surg & Facial Plast Sur, Lindwurmstr 2a, D-80337 Munich, Germany
[2] Tech Univ Munich, Sch Med, Klinikum Rechts Isar, Dept Diagnost & Intervent Neuroradiol, Munich, Germany
[3] LMU Munchen, Univ Hosp, Dept Prosthet Dent, Munich, Germany
[4] Tech Univ Munich, Sch Med, Klinikum Rechts Isar, Dept Oral & Maxillofacial Surg, Munich, Germany
[5] Tech Univ Munich, Sch Med, Klinikum Rechts Isar, Dept Diagnost & Intervent Radiol, Munich, Germany
关键词
additive manufacturing; CAD; CAM; computer-assisted surgery; craniomaxillofacial surgery; dental imaging; guided-implant surgery; image processing; implant surgery; magnetic resonance imaging; radiology; SEGMENTATION PROCESS; IMPLANT-SURGERY; ULTRASHORT TIME; CT; MRI; SEQUENCES; IMAGES; COIL;
D O I
10.1111/cid.13033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Providing accurate 3-dimensional virtual bone surface models is a prerequisite for virtual surgical planning and additive manufacturing in craniomaxillofacial surgery. For this purpose, magnetic resonance imaging (MRI) may be a radiation-free alternative to computed tomography (CT) and cone beam computed tomography (CBCT). Purpose The aim of this study was to assess the geometric accuracy of 3-dimensional T1-weighted MRI-derived virtual bone surface models of the mandible in comparison to CT and CBCT. Materials and methods Specimens of the mandible from porcine cadavers were scanned with (1) a 3-dimensional T1-weighted MRI sequence (0.6 mm isotropic voxel) optimized for bone imaging, (2) CT, and (3) CBCT. Cortical mandibular structures (n = 10) were segmented using semiautomated and manual techniques. Imaging-based virtual 3-dimensional models were aligned with a high-resolution optical 3-dimensional surface scan of the dissected bone (=ground truth) and global geometric deviations were calculated (mean surface distance [MSD]/root-mean-square distance [RMSD]). Agreement between the imaging modalities was assessed by equivalence testing and Bland-Altman analysis. Results Intra- and inter-rater agreement was on a high level for all modalities. Global geometric deviations (MSD/RMSD) between optical scans and imaging modalities were 0.225 +/- 0.020 mm/0.345 +/- 0.074 mm for CT, 0.280 +/- 0.067 mm/0.371 +/- 0.074 mm for MRI, and 0.352 +/- 0.076 mm/0.454 +/- 0.071 mm for CBCT. All imaging modalities were statistically equivalent within an equivalence margin of +/- 0.3 mm, and Bland-Altman analysis indicated high agreement as well. Conclusions The results of this study indicate that the accuracy and reliability of MRI-derived virtual 3-dimensional bone surface models is equal to CT and CBCT. MRI may be considered as a reliable alternative to CT and CBCT in computer-assisted craniomaxillofacial surgery.
引用
收藏
页码:779 / 788
页数:10
相关论文
共 50 条
  • [1] The accuracy of 3-dimensional magnetic resonance 3D vibe images of the mandible: an in vitro comparison of magnetic resonance imaging and computed tomography
    Goto, Tazuko K.
    Nishida, Satoko
    Nakamura, Yuko
    Tokumori, Kenji
    Nakamura, Yasuhiko
    Kobayashi, Koji
    Yoshida, Yutaka
    Yoshiura, Kazunori
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (04): : 550 - 559
  • [2] Imaging of Osseointegrated Implants in the Temporal Bone by Accuitomo 3-Dimensional Cone Beam Computed Tomography
    Granstrom, Gosta
    Grondahl, Hans-Goran
    OTOLOGY & NEUROTOLOGY, 2011, 32 (02) : 199 - 203
  • [3] Validation of cone-beam computed tomography and magnetic resonance imaging of the porcine spine: a comparative study with multidetector computed tomography and anatomical specimens
    Costa de Freitas, Ricardo Miguel
    Andrade, Celi Santos
    Mendes Pereira Caldas, Jose Guilherme
    Kanas, Alexandre Fligelman
    Cabral, Richard Halti
    Tsunemi, Miriam Harumi
    Cervantes Rodriguez, Hernan Joel
    Rabbani, Said Rahnamaye
    SPINE JOURNAL, 2015, 15 (05): : 992 - 999
  • [4] Comparison of the Accuracy of 3-dimensional Cone-beam Computed Tomography and Micro-Computed Tomography Reconstructions by Using Different Voxel Sizes
    Maret, Delphine
    Peters, Ove A.
    Galibourg, Antoine
    Dumoncel, Jean
    Esclassan, Remi
    Kahn, Jean-Luc
    Sixou, Michel
    Telmon, Norbert
    JOURNAL OF ENDODONTICS, 2014, 40 (09) : 1321 - 1326
  • [5] Dimensional measurement accuracy of 3-dimensional models from cone beam computed tomography using different voxel sizes
    Mukhia, Nirza
    Birur, N. Praveen
    Shubhasini, A. R.
    Shubha, G.
    Keerthi, G.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2021, 132 (03): : 361 - 369
  • [6] Superimposition of 3-dimensional cone-beam computed tomography models of growing patients
    Cevidanes, Lucia H. C.
    Heymann, Gavin
    Cornelis, Marie A.
    DeClerck, Hugo J.
    Tulloch, J. F. Camilla
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 94 - 99
  • [7] Image analysis and superimposition of 3-dimensional cone-beam computed tomography models
    Cevidanes, Lucia H. S.
    Styner, Martin A.
    Proffit, William R.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 129 (05) : 611 - 618
  • [8] Evaluation of Visibility of Foreign Bodies in the Maxillofacial Region: Comparison of Computed Tomography, Cone Beam Computed Tomography, Ultrasound and Magnetic Resonance Imaging
    Valizadeh, Solmaz
    Pouraliakbar, Hamidreza
    Kiani, Leila
    Safi, Yaser
    Alibakhshi, Leila
    IRANIAN JOURNAL OF RADIOLOGY, 2016, 13 (04)
  • [9] Measurement of Glenoid Bone Loss With 3-Dimensional Magnetic Resonance Imaging: A Matched Computed Tomography Analysis
    Vopat, Bryan G.
    Cai, Wenli
    Torriani, Martin
    Vopat, Matthew L.
    Hemma, Murali
    Harris, Gordon J.
    Schantz, Kati
    Provencher, Matthew T.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (12): : 3141 - 3147
  • [10] Advances in Hip Imaging: 3-Dimensional Computed Tomography, Magnetic Resonance Imaging, and Dynamic Imaging
    Mlynarek, Ryan A.
    Weber, Alexander E.
    Ross, James R.
    Bedi, Asheesh
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2015, 23 (03) : 166 - 174