International comparison of C-peptide measurements

被引:29
|
作者
Wiedmeyer, Hsiao-Mei
Polonsky, Kenneth S.
Myers, Gary L.
Little, Randie R.
Greenbaum, Carla J.
Goldstein, David E.
Palmer, Jerry P.
机构
[1] Univ Missouri, Sch Med, Dept Pathol & Anat Sci, Columbia, MO 65212 USA
[2] Univ Missouri, Sch Med, Dept Child Hlth, Columbia, MO 65212 USA
[3] Washington Univ, Sch Med, Dept Med, St Louis, MO 63110 USA
[4] Ctr Environm Hlth F25, Div Environm Hlth Lab Sci, Ctr Dis Control & Prevent, Chamblee, GA USA
[5] Benaroya Res Inst, Seattle, WA USA
[6] Univ Washington, Seattle, WA 98195 USA
[7] VA Med Ctr, Seattle, WA USA
关键词
D O I
10.1373/clinchem.2006.081570
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: C-peptide measurement has been widely used as a marker of insulin secretion in patients with diabetes. We assessed the comparability of C-peptide results obtained with different methods and by different laboratories and determined whether C-peptide results could be harmonized by normalization with a WHO reference reagent or with plasma. Methods: We sent 16 different heparin plasma samples to 15 laboratories in 7 countries. The samples were analyzed with 10 different assay methods. A WHO C-peptide standard was also sent to each laboratory and used to determine the feasibility of normalizing results. To assess the impact of calibrator matrix on the comparability of results, we also used the mean results of all laboratories for 4 of the samples to normalize the remaining sample results. Results: Between-laboratory variability increased with increasing C-peptide concentrations. Normalization of results with WHO reference reagents did not improve comparability, but normalization with samples significantly improved comparability among laboratories and methods. The 95% confidence interval estimate for the SD for the lab/method effect (0.0-0.061) using sample-normalized values did not overlap with the 95% CI estimate with the raw data (0.090-0.225). Conclusions: C-peptide results generated by different methods and different laboratories do not always agree, especially at higher concentrations of C-peptide. These data support the concept of using a single laboratory for multisite studies and support efforts to harmonize C-peptide measurements by use of calibrators prepared in the sample matrix. (c) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:784 / 787
页数:4
相关论文
共 50 条
  • [1] International comparison of C-peptide measurements
    Wiedmeyer, HM
    [J]. DIABETES, 2005, 54 : A243 - A243
  • [2] International standardization of C-peptide measurements to a reference method
    Little, R. R.
    Tennill, A. L.
    Rohlfing, C. L.
    Stein, D. T.
    Rogatsky, E.
    Myers, G. L.
    Polonsky, K. S.
    Greenbaum, C. J.
    Palmer, J. P.
    Goldstein, D. E.
    [J]. CLINICAL CHEMISTRY, 2007, 53 (06) : A198 - A199
  • [3] Standardization of C-peptide measurements
    Little, Randie R.
    Rohlfing, Curt L.
    Tennill, Alethea L.
    Madsen, Richard W.
    Polonsky, Kenneth S.
    Myers, Gary L.
    Greenbaum, Carla J.
    Palmer, Jerry P.
    Rogatsky, Eduard
    Stein, Daniel T.
    [J]. CLINICAL CHEMISTRY, 2008, 54 (06) : 1023 - 1026
  • [4] METHODOLOGICAL ASPECTS ON C-PEPTIDE MEASUREMENTS
    LUDVIGSSON, J
    [J]. ACTA MEDICA SCANDINAVICA, 1983, : 53 - 59
  • [5] COMPARISON OF COMMERCIAL C-PEPTIDE RADIOIMMUNOASSAYS
    KOSKINEN, P
    KAIHOLA, HL
    IRJALA, K
    VIIKARI, J
    [J]. ACTA ENDOCRINOLOGICA, 1987, 115 : 32 - 32
  • [6] USE OF A COMMON STANDARD FOR COMPARISON OF INSULIN C-PEPTIDE MEASUREMENTS BY DIFFERENT LABORATORIES
    CAYGILL, CPJ
    GAINESDAS, RE
    BANGHAM, DR
    [J]. DIABETOLOGIA, 1980, 18 (03) : 197 - 204
  • [7] Evaluation of use of singleton measurements of C-peptide by RIA
    Stickle, DF
    McNeil, SE
    [J]. CLINICA CHIMICA ACTA, 1999, 283 (1-2) : 195 - 200
  • [8] C-PEPTIDE
    HOEKSTRA, JBL
    VANRIJN, HJM
    ERKELENS, DW
    THIJSSEN, JHH
    [J]. DIABETES CARE, 1982, 5 (04) : 438 - 446
  • [9] C-PEPTIDE
    DORNER, M
    [J]. ANNALES DE MEDECINE INTERNE, 1984, 135 (06): : 414 - 415
  • [10] Standardization of C-peptide measurements in urine by method comparison with isotope-dilution mass spectrometry
    Fierens, C
    Stöckl, D
    Baetens, D
    De Leenheer, AP
    Thienpont, LM
    [J]. CLINICAL CHEMISTRY, 2003, 49 (06) : 992 - 994