A change-point model for a shift in variance

被引:105
|
作者
Hawkins, DM [1 ]
Zamba, KD
机构
[1] Univ Minnesota, Sch Stat, Minneapolis, MN 55455 USA
[2] Univ Iowa, Coll Publ Hlth, Dept Biostat, Iowa City, IA 52242 USA
关键词
average run length; change point; control chart; CUSUM; EWMA; likelihood ratio; Phase I; Phase II; Shewhart;
D O I
10.1080/00224065.2005.11980297
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A control chart for detecting shifts in the variance of a process is developed for the case where the nominal value of the variance is unknown. As our approach does not require that the in-control variance be known a priori, it avoids the need for a lengthy Phase I data-gathering step before charting can begin. The method is a variance-change-point model, based on the likelihood ratio test for a change in variance with the conventional Bartlett correction, adapted for repeated sequential use. The chart may be used alone in settings where one wishes to monitor one-degree-of-freedom chi-squared variates for departure from control; or it may be used together with a parallel change-point methodology for the mean to monitor process data for shifts in mean and/or variance. In both the solo use and as the scale portion of a combined scheme for monitoring changes in mean and/or variance, the approach has good performance across the range of possible shifts.
引用
收藏
页码:21 / 31
页数:11
相关论文
共 50 条