Validation of a non-invasive fluorescence imaging system to monitor dermatological PDT

被引:23
|
作者
Tyrrell, Jessica [1 ]
Campbell, Sandra [1 ]
Curnow, Alison [1 ]
机构
[1] Univ Exeter, Peninsula Med Sch, Royal Cornwall Hosp, Knowledge Spa, Truro TR1 3HD, Cornwall, England
关键词
Dermatology; Fluorescence diagnosis (FD); Non-invasive fluorescence imaging; Metvix (R); Methyl-aminolevulinate (MAL); Photodynamic therapy (PDT); PROTOPORPHYRIN-IX FLUORESCENCE; BASAL-CELL CARCINOMA; ACID-PHOTODYNAMIC THERAPY; 5-AMINOLEVULINIC ACID; IN-VIVO; AMINOLEVULINIC ACID; TOPICAL APPLICATION; ACTINIC KERATOSIS; HUMAN-SKIN; PSORIASIS;
D O I
10.1016/j.pdpdt.2010.03.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Methyl-aminolevulinate (MAL) photodynamic therapy (PDT) involves selective accumulation of a photosensitiser, protoporphyrin IX (PpIX), primarily in tumour tissue, which in combination with visible light and tissue oxygen results in reactive oxygen species (ROS) production and thus cellular destruction. Methods: A non-invasive fluorescence imaging system (Dyaderm, Biocam, Germany) has been employed to acquire colour (morphological) and fluorescent (physiological) images simultaneously during dermatological PDT. This system had been previously utilised for fluorescence diagnosis, however, here changes in PpIX concentration within the skin lesions and normal tissue were followed after MAL application. Measurements were also recorded from a synthetic PpIX standard. Results: Results indicated that imaging distance, imaging angle, position of the region of interest and light conditions all altered the PpIX levels acquired from the synthetic PpIX standard. The imaging system was therefore adapted and a standard operating procedure developed allowing reproducible images of dermatological lesions to be acquired. Different concentrations of synthetic PpIX were analysed with the system and a linear relationship was observed between the PpIX concentration and the mean greyscale value calculated for the images acquired up to 10 mu M. Conclusions: The Dyaderm imaging system can now be used reproducibly with confidence to semi-quantify PpIX (within the range of 0-10 mu M) within dermatological lesions using the standard operating procedure derived from this work. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 97
页数:12
相关论文
共 50 条
  • [1] The utilization of a non-invasive fluorescence imaging system to follow clinical dermatological MAL-PDT
    Tyrrell, Jessica
    Campbell, Sandra
    Curnow, Alison
    12TH WORLD CONGRESS OF THE INTERNATIONAL PHOTODYNAMIC ASSOCIATION: PHOTODYNAMIC THERAPY: BACK TO THE FUTURE, 2009, 7380
  • [2] Fluorescence imaging as a non-invasive technology to monitor the performance of glyphosate adjuvants and formulations
    De Ruiter, H.
    Mack, B.
    Van Der Schoor, R.
    Jalink, H.
    Journal of ASTM International, 2007, 4 (09):
  • [3] Fluorescence imaging as a non-invasive technology to monitor the performance of glyphosate adjuvants and formulations
    de Ruiter, H.
    Mack, B.
    van der Schoor, R.
    Jalink, H.
    PESTICIDE FORMULATIONS AND DELIVERY SYSTEMS, 27TH VOLUME: TRADITIONAL AND NON-TRADITIONAL DEVELOPMENTS, 2008, 1500 : 87 - +
  • [4] Non-invasive imaging to monitor pancreatic islets function
    Mirbolooki, M. Reza
    Alexander, Michael
    Kant, Ritu
    Constantinescu, Cristian
    Pan, Min-liang
    Pandey, Suresh
    Coleman, Robert
    Milne, Norah
    Hoyt, David B.
    Mukherjee, Jogesh
    Lakey, Jonathan R. T.
    XENOTRANSPLANTATION, 2009, 16 (05) : 417 - 417
  • [5] Non-invasive fluorescence imaging of intestinal motility
    Kwon, S. -K.
    Davies-Venn, C.
    Sevick-Mu-Raca, E.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2012, 24 : 51 - 51
  • [6] A NOVEL ULTRAVIOLET FLUORESCENCE IMAGING TECHNIQUE AS A NON-INVASIVE AND RAPID METHOD TO MONITOR EPIDERMAL GROWTH
    Purschke, Martin
    Wang, Ying
    Taghados, Seyed Javid
    Farinelli, William A.
    Franco, Walfre
    Anderson, R. Rox
    Doukas, Apostolos
    LASERS IN SURGERY AND MEDICINE, 2013, 45 : 27 - 27
  • [7] Validation of a non-invasive arterial monitor GATE model for PET
    Giansiracusa, P. J.
    Peake, D. J.
    Sobott, B. A.
    O'Keefe, G.
    Rassool, R. P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 737 : 47 - 51
  • [8] New tools to monitor stress using non-invasive PET imaging
    Eckelman, WC
    Rice, KC
    Contoreggi, C
    STRESS: CURRENT NEUROENDOCRINE AND GENETIC APPROACHES, 2004, 1018 : 487 - 494
  • [9] Activatable probes for non-invasive small animal fluorescence imaging
    Texier, Isabelle
    Razkin, Jesus
    Josserand, Veronique
    Boturyn, Didier
    Dumy, Pascal
    Coll, Jean-Luc
    Rizo, Philippe
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 165 - 168
  • [10] Non-invasive in vivo tracking of fibrin degradation by fluorescence imaging
    Wolbank, Susanne
    Pichler, Valentin
    Ferguson, James Crawford
    Meinl, Alexandra
    van Griensven, Martijn
    Goppelt, Andreas
    Redl, Heinz
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2015, 9 (08) : 973 - 976