Development of a straightness measurement and compensation system with multiple right-angle reflectors and a lead zirconate titanate-based compensation stage

被引:9
|
作者
Liu, Chien-Hung [1 ]
Chen, Jui-Hung [1 ]
Teng, Yun-Feng [2 ]
机构
[1] Natl Formosa Univ, Inst Electroopt & Mat Sci, Huwei 632, Yunlin, Taiwan
[2] Natl Chung Cheng Univ, Dept Mech Engn, Chiayi 621, Taiwan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2009年 / 80卷 / 11期
关键词
D O I
10.1063/1.3254018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents a real-time straightness measurement and compensation system with an optical straightness measurement system and a single-axis flexure-hinge type lead zirconate titanate (PZT)-based compensation stage. The optical straightness measurement system consists of a He-Ne laser, a quadrant photodiode detector, and five right-angle reflectors. Multiple laser beam reflections between the right-angle reflectors increase the sensitivity of the straightness measurement by a factor of 6. The right-angle reflectors can be moved by the flexure-hinge type PZT based compensation stage that is actuated by a PZT actuator to ensure that the laser beam is always projected onto the center of the quadrant detector. These two systems are integrated and fixed on a scanning stage. The resolution of the straightness measurement system is 0.1 mu m. Using the real-time straightness compensation system, the straightness error of the scanning stage is fed back to the control system. The compensated straightness error of the scanning stage system was reduced from 6.5 mu m to less than 1 mu m. (C) 2009 American Institute of Physics. [doi:10.1063/1.3254018]
引用
收藏
页数:5
相关论文
共 12 条
  • [1] Mechanomyogram measurement by lead zirconate titanate-based acoustic sensor
    Takei, Yusuke
    Aoki, Ryo
    Kobayashi, Takeshi
    Takahata, Tomoyuki
    Shimoyama, Isao
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2018, 57 (11)
  • [2] Improvement of the nonlinear dynamic response of a Z-tilts lead zirconate titanate-based compensation stage using the capacitor insertion method
    Liu, Chien-Hung
    Chen, Chieh-Li
    Lee, Hau-Wei
    Jywe, Wen-Yuh
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (11):
  • [3] A Straightness Error Compensation System for Topography Measurement Based on Thin Film Interferometry
    Su, Hang
    Ye, Ruifang
    Cheng, Fang
    Cui, Changcai
    Yu, Qing
    PHOTONICS, 2021, 8 (05)
  • [4] Development of a straightness measuring system and compensation technique using multiple corner cubes for precision stages
    Liu, C-H
    Jywe, W-Y
    Jeng, Y-R
    Huang, H-L
    Hsu, T-H
    Wang, M-S
    Deng, S-Y
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2010, 224 (B3) : 483 - 492
  • [5] Development of a Stress Sensor Based on the Piezoelectric Lead Zirconate Titanate for Impact Stress Measurement
    Liu, Yiming
    Xu, Bin
    Li, Lifei
    Li, Bing
    THIRD INTERNATIONAL CONFERENCE ON SMART MATERIALS AND NANOTECHNOLOGY IN ENGINEERING, 2012, 8409
  • [6] A Gas Flow Measurement System Based on Lead Zirconate Titanate Piezoelectric Micromachined Ultrasonic Transducer
    Liu, Tao
    Li, Zhihao
    Zhang, Jiahuan
    Li, Dongxiao
    Dou, Hanjie
    Wu, Pengfan
    Yang, Jiaqian
    Zhang, Wangyang
    Mu, Xiaojing
    MICROMACHINES, 2024, 15 (01)
  • [7] Angle measurement-based compensation methodology to mitigate voltage unbalance in a distribution system
    Kallamadi, Manjunath
    Chhabhaya, Dwarkesh
    Shah, Krupa
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (03):
  • [8] Development of a three-dimensional angle errors detection and compensation system for two-dimensional stage
    Huang, Qiang-Xian
    Bian, Ya-Kui
    Chen, Chen
    Li, Rui-Jun
    SEVENTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2016, 9903
  • [9] Dynamic error compensation for the angle measurement system based on phase-detecting using in the inertial navigation test table with high accuracy
    Wang, Mao
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2001, 33 (05): : 628 - 631
  • [10] Precise measurement of particle size in colloid system based on the development of multiple-angle dynamic light scattering apparatus
    Lu Huang
    Miao Sun
    Sitian Gao
    Yushu Shi
    Wei Li
    Applied Physics B, 2020, 126