Evaluation of the chemical composition and correlation between the calculated and measured odour concentration of odorous gases from a landfill in Beijing, China
被引:95
|作者:
Wu, Chuandong
[1
]
Liu, Jiemin
[1
]
Zhao, Peng
[2
]
Li, Wenhui
[1
]
Yan, Luchun
[3
]
Piringer, Martin
[4
]
Schauberger, Guenther
[5
]
机构:
[1] Univ Sci & Technol Beijing, Sch Chem & Biol Engn, Beijing 100083, Peoples R China
[2] Beijing Municipal Inst Labor Protect, Key Lab Occupat Hlth & Safety, Beijing 100054, Peoples R China
[3] Univ Sci & Technol Beijing, Sch Mat Sci & Engn, Beijing 100083, Peoples R China
[4] Cent Inst Meteorol & Geodynam, Dept Environm Meteorol, Vienna, Austria
[5] Univ Vet Med, Unit Physiol & Biophys, WG Environm Hlth, Vienna, Austria
基金:
中国国家自然科学基金;
关键词:
Landfill;
Ammonia;
Odour threshold;
Odour activity value;
Odour concentration;
REDUCED SULFUR-COMPOUNDS;
VOLATILE ORGANIC-COMPOUNDS;
MUNICIPAL SOLID-WASTE;
DYNAMIC OLFACTOMETRY;
TEMPORAL VARIATION;
MASS-SPECTROMETRY;
EMISSION RATES;
ENVIRONMENT;
SURFACE;
THRESHOLDS;
D O I:
10.1016/j.atmosenv.2017.06.010
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
Odorous gases emitted from landfills have always been a public concern, but studies evaluating the odour contribution and the correlation between the odour concentrations are limited. The objectives of this study were to assess the odour contribution and to correlate the measured odour concentration Coo with the calculated odour concentration SOAV, which was calculated as sum of individual odour activity value (OAV). Odorous air samples from a landfill in Beijing were collected seasonally and measured by both gas chromatography and an olfactometer. Different from previous studies, we measured the odour threshold of 51 detected compounds using a uniform methodology to minimize the imprecision of citing odour threshold from disparate literature. The odour threshold is used to convert the individual chemical concentration into the OAV, which is used as a surrogate of the odour concentration. Evaluation of the OAV revealed that hydrogen sulfide (65.9%), dimethyl sulfide (14.4%) and trimethylamine (8.6%) contributed the most to the odour at the landfill. Moreover, the correlation between the calculated odour concentration SOAV and the measured odour concentration Cop resulted in a linear regression equation of C-OD = 6.28 SOAV (r = 0.914, n = 24,p < 0.01). Based on the scaling factor K=6.28, the average ratio of calculated odour concentration to measured odour concentration could be improved from less than 0.2 to 1.1. By the calibration of the calculated odour concentration SOAV, it is possible to use continuous measurements of chemical concentrations to derive odour concentration for this site for monitoring purposes. (C) 2017 Elsevier Ltd. All rights reserved.