Fire Protective Glass Fiber Reinforced Concrete Plates for Steel Structures under Different Types of Fire Exposure

被引:9
|
作者
Gravit, Marina [1 ]
Golub, Elena [2 ]
Klementev, Boris [3 ]
Dmitriev, Ivan [1 ]
机构
[1] Peter Great St Petersburg Polytech Univ, Civil Engn Inst, Peter Great St, 195251 St, St Petersburg 195251, Russia
[2] State Hermitage Museum, St Petersburg 190000, Russia
[3] LLC Arctic LNG 2, Dept Expertise, Moscow 117393, Russia
关键词
fire resistance; hydrocarbon fire; fire protection; computer simulation; steel structure; BEHAVIOR;
D O I
10.3390/buildings11050187
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In a situation where a fire occurs either in a tunnel with a burning vehicle carrying petroleum products, at an offshore platform, or at an oil and gas asset to be protected, such a case is commonly described using a hydrocarbon fire curve. Therefore, it is extremely important to design construction, which can maintain stability and bearing capacity both under the standard and hydrocarbon fire modes. The purpose in this work is to hold a behavior simulation of a steel structure with fireproofing ensured through lightweight concrete slabs reinforced with fiber glass as well as a validation of the outcomes by assessing the experimental findings obtained from the relevant fire tests. A fire resistance study was carried out here for steel structures with a profile ratio of 156 mm(-1) for the cases of a standard fire and of a hydrocarbon fire. A constant static load of 687 kN (70 tf) was taken for standard fire and 294 kN (30 tf) for hydrocarbon fire; the column was under vertical compression with one end resting on a hinged support and the other end rigidly fixed. The specimen design incorporated single-layer box-section cladding made of Pyro-Safe Aestuver T slabs, 40 mm thick and of a 650 kg/m(3) density, pre-cut to fit the column size. The column strength loss (R) ultimately occurred after 240 min in the standard fire case and after 180 min in the hydrocarbon fire case. As the breach in the fireproofing structural integrity (E) or the installation accuracy cannot be considered, the limit state indicators may show certain discrepancies. According to the simulation performed using SOFiSTiK software, the design fire resistance rating of the structure in a hydrocarbon fire case was 58% higher than the figure obtained by holding fire tests due to the slabs cracking during the experiment session; the discrepancy between the outcomes of the session and the simulation in a standard fire case was as much as 15%.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Dynamic Behaviour of Steel Fiber Reinforced Concrete Plates Under Gun Fire and Free Fall Tests
    Zohrabyan, Vahan
    Seltner, Tobias
    Braml, Thomas
    Keuser, Manfred
    FIBRE REINFORCED CONCRETE: IMPROVEMENTS AND INNOVATIONS II, BEFIB 2021, 2022, 36 : 244 - 254
  • [2] Study on impact resistance of steel fiber reinforced concrete after exposure to fire
    Wang, Wenjie
    Zhang, Yunpeng
    Mo, Zonglai
    Wei, Hong
    HIGH TEMPERATURE MATERIALS AND PROCESSES, 2024, 43 (01)
  • [3] EVALUATION OF THE BEARING CAPACITY OF FIBER REINFORCED CONCRETE SECTIONS UNDER FIRE EXPOSURE
    Di Carlo, Fabio
    Meda, Alberto
    Rinaldi, Zila
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON MECHANICS AND MATERIALS IN DESIGN (M2D2017), 2017, : 1625 - 1626
  • [4] Evaluation of the bearing capacity of fiber reinforced concrete sections under fire exposure
    Fabio Di Carlo
    Alberto Meda
    Zila Rinaldi
    Materials and Structures, 2018, 51
  • [5] Evaluation of the bearing capacity of fiber reinforced concrete sections under fire exposure
    Di Carlo, Fabio
    Meda, Alberto
    Rinaldi, Zila
    MATERIALS AND STRUCTURES, 2018, 51 (06)
  • [6] Fire performance of steel reinforced concrete (SRC) structures
    Han, Linhai
    Tan, Qinghua
    Song, Tianyi
    9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY, 2013, 62 : 46 - 55
  • [7] Fire Resistance Performance of Glass Fiber Reinforced Concrete Columns
    Mohamed, Zitouni
    Belkacem, Lamri
    Abdelhak, Kada
    CIGOS 2021, EMERGING TECHNOLOGIES AND APPLICATIONS FOR GREEN INFRASTRUCTURE, 2022, 203 : 275 - 283
  • [8] Research and design guidelines for the construction of fiber-reinforced polymer reinforced concrete structures under fire exposure: A brief review
    Faruqi, M. A.
    Escobedo, G.
    Sun, D.
    Sai, J.
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2013, 32 (17) : 1302 - 1309
  • [9] FIRE PERFORMANCE OF STEEL HOLLOW COLUMNS FILLED WITH CONCRETE, REINFORCED CONCRETE AND FIBER REINFORCED CONCRETE
    Pires, Tiago A. C.
    Rodrigues, Joao Paulo C.
    do Rego Silva, Jose Jeferson
    Correia, Antonio M.
    ICEM15: 15TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2012,
  • [10] Behaviour of concrete beams reinforced using basalt and steel bars under fire exposure
    Hassan, Ahmed
    Khairallah, Fouad
    Elsayed, Hend
    Salman, Amany
    Mamdouh, Hala
    ENGINEERING STRUCTURES, 2021, 238