Speech recognition under conditions of frequency-place compression and expansion

被引:80
|
作者
Baskent, D
Shannon, RV
机构
[1] House Ear Res Inst, Dept Auditory Implants & Percept, Los Angeles, CA 90057 USA
[2] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
来源
关键词
D O I
10.1121/1.1558357
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In normal acoustic hearing the mapping of acoustic frequency information onto the appropriate, cochlear place is a natural biological function, but in cochlear implants it is controlled by. the speech processor. The cochlear tonotopic range of the implant is determined by the length and insertion depth of the electrode array. Conventional cochlear implant electrode arrays are designed for an insertion of 25 mm inside the round window and the active electrodes occupy 16 mm, which would place the electrodes in a cochlear region corresponding to an acoustic frequency range of 500-6000 Hz. However, some implant speech processors map an,acoustic frequency range from 150 to 10 000 Hz onto these electrodes. While this mapping preserves the entire range of acoustic frequency information, it also results in a compression of the tonotopic pattern of speech information delivered to the brain. The present study measured the effects of such a compression of frequency-to-place mapping on speech recognition using acoustic simulations. Also measured were the effects, of an expansion of the frequency-to-place mapping, which produces an expanded representation of speech in the cochlea. Such an expanded representation might improve speech recognition. by improving the relative spatial (tonotopic) resolution, like. an "acoustic fovea." Phoneme and sentence recognition was measured as a function of linear (in terms of cochlear distance) frequency-place compression and expansion. These conditions were presented to normal-hearing listeners using a noise-band vocoder, simulating cochlear implant electrodes with different insertion depths and different number of electrode channels. The cochlear tonotopic range was held constant by employing the same noise carrier bands for each condition, while the analysis frequency range was either compressed or expanded relative to the carrier frequency range. For each condition, the result was compared to that of the perfect frequency-place match, where the carrier and the analysis bands were perfectly matched. Speech recognition in the matched conditions was generally better than any,condition of frequency-place expansion and compression, even when the matched condition. eliminated a considerable amount of acoustic information. This result suggests that speech recognition, at least without training, is dependent. on the. mapping of acoustic frequency information onto the appropriate cochlear place. C 2003 Acoustical Society of America.
引用
收藏
页码:2064 / 2076
页数:13
相关论文
共 50 条
  • [1] Frequency-place compression and expansion in cochlear implant listeners
    Baskent, D
    Shannon, RV
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 116 (05): : 3130 - 3140
  • [2] Melody Recognition in Dichotic Listening With or Without Frequency-Place Mismatch
    Zhou, Ning
    Xu, Li
    EAR AND HEARING, 2014, 35 (03): : 379 - 382
  • [3] Combined effects of frequency compression-expansion and shift on speech recognition
    Baskent, Deniz
    Shannon, Robert V.
    EAR AND HEARING, 2007, 28 (03): : 277 - 289
  • [4] Effects of Electrode Array Length on Frequency-Place Mismatch and Speech Perception with Cochlear Implants
    Venail, Frederic
    Mathiolon, Caroline
    de Champfleur, Sophie Menjot
    Piron, Jean Pierre
    Sicard, Marielle
    Villemus, Francoise
    Vessigaud, Marie Aude
    Sterkers-Artieres, Francoise
    Mondain, Michel
    Uziel, Alain
    AUDIOLOGY AND NEURO-OTOLOGY, 2015, 20 (02) : 102 - 111
  • [5] METHOD FOR TIME OR FREQUENCY COMPRESSION EXPANSION OF SPEECH
    FAIRBANKS, G
    EVERITT, WL
    JAEGER, RP
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1953, 41 (03): : 425 - 426
  • [6] An anatomically based frequency-place map for the mouse cochlea
    Ou, HC
    Harding, GW
    Bohne, BA
    HEARING RESEARCH, 2000, 145 (1-2) : 123 - 129
  • [7] COCHLEAR FREQUENCY-PLACE MAP IN ADULT CHICKENS - INTRACELLULAR BIOCYTIN LABELING
    CHEN, L
    SALVI, R
    SHERO, M
    HEARING RESEARCH, 1994, 81 (1-2) : 130 - 136
  • [8] IMAGE-GUIDED CUSTOMIZATION OF FREQUENCY-PLACE MAPPING IN COCHLEAR IMPLANTS
    Ali, Hussnain
    Noble, Jack H.
    Gifford, Rene H.
    Labadie, Robert F.
    Dawant, Benoit M.
    Hansen, John H. L.
    Tobey, Emily
    2015 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING (ICASSP), 2015, : 5843 - 5847
  • [9] The effects of frequency-place shift on consonant confusion in cochlear implant simulations
    Zhou, Ning
    Xu, Li
    Lee, Chao-Yang
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2010, 128 (01): : 401 - 409
  • [10] Investigating Interaural Frequency-Place Mismatches via Bimodal Vowel Integration
    Guerit, Francois
    Santurette, Sebastien
    Chalupper, Josef
    Dau, Torsten
    TRENDS IN HEARING, 2014, 18