Joint Reconstruction of Multi-contrast Images and Multi-channel Coil Sensitivities

被引:1
|
作者
Chen, Zhongzhou [1 ,2 ]
Ren, Yanan [1 ,3 ]
Su, Shi [1 ]
Shi, Caiyun [1 ]
Ji, Jim X. [4 ]
Zheng, Hairong [1 ]
Liu, Xin [1 ]
Xie, Guoxi [5 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen, Peoples R China
[3] Northeastern Univ, Sino Dutch Biomed & Informat Engn Sch, Shenyang, Peoples R China
[4] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX USA
[5] Guangzhou Med Univ, Sch Basic Sci, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
COMPRESSED SENSING MRI; ACQUISITION;
D O I
10.1007/s00723-017-0919-4
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Magnetic resonance imaging (MRI) has an important feature that it provides multiple images with different contrasts for complementary diagnostic information. However, a large amount of data is needed for multi-contrast images depiction, and thus, the scan is time-consuming. Many methods based on parallel magnetic resonance imaging (pMRI) and compressed sensing (CS) are applied to accelerate multi-contrast MR imaging. Nevertheless, the image reconstructed by sophisticated pMRI methods contains residual aliasing artifact that degrades the quality of the image when the acceleration factor is high. Other methods based on CS always suffer the regularization parameter-selecting problem. To address these issues, a new method is presented for joint multi-contrast image reconstruction and coil sensitivity estimation. The coil sensitivities can be shared during the reconstruction due to the identity of coil sensitivity profiles of different contrast images for imaging stationary tissues. The proposed method uses the coil sensitivities as sharable information during the reconstruction to improve the reconstruction quality. As a result, the residual aliasing artifact can be effectively removed in the reconstructed multi-contrast images even if the acceleration factor is high. Besides, as there is no regularization term in the proposed method, the troublesome regularization parameter selection in the CS can also be avoided. Results from multi-contrast in vivo experiments demonstrated that multi-contrast images can be jointly reconstructed by the proposed method with effective removal of the residual aliasing artifact at a high acceleration factor.
引用
收藏
页码:955 / 969
页数:15
相关论文
共 50 条
  • [1] Joint Reconstruction of Multi-contrast Images and Multi-channel Coil Sensitivities
    Zhongzhou Chen
    Yanan Ren
    Shi Su
    Caiyun Shi
    Jim X. Ji
    Hairong Zheng
    Xin Liu
    Guoxi Xie
    [J]. Applied Magnetic Resonance, 2017, 48 : 955 - 969
  • [2] Simultaneous use of individual and joint regularization terms in compressive sensing: Joint reconstruction of multi-channel multi-contrast MRI acquisitions
    Kopanoglu, Emre
    Gungor, Alper
    Kilic, Toygan
    Saritas, Emine Ulku
    Oguz, Kader K.
    Cukur, Tolga
    Guven, H. Emre
    [J]. NMR IN BIOMEDICINE, 2020, 33 (04)
  • [3] Vectorial total generalized variation for accelerated multi-channel multi-contrast MRI
    Chatnuntawech, Itthi
    Martin, Adrian
    Bilgic, Berkin
    Setsompop, Kawin
    Adalsteinsson, Elfar
    Schiavi, Emanuele
    [J]. MAGNETIC RESONANCE IMAGING, 2016, 34 (08) : 1161 - 1170
  • [4] Multi-channel, Multi-slice, and Multi-contrast Compressed Sensing MRI UsingWeighted Forest Sparsity and Joint TV Regularization Priors
    Datta, Sumit
    Deka, Bhabesh
    [J]. SOFT COMPUTING FOR PROBLEM SOLVING, SOCPROS 2017, VOL 1, 2019, 816 : 821 - 832
  • [5] Joint sparse reconstruction of multi-contrast MRI images with graph based redundant wavelet transform
    Lai, Zongying
    Zhang, Xinlin
    Guo, Di
    Du, Xiaofeng
    Yang, Yonggui
    Guo, Gang
    Chen, Zhong
    Qu, Xiaobo
    [J]. BMC MEDICAL IMAGING, 2018, 18
  • [6] Joint sparse reconstruction of multi-contrast MRI images with graph based redundant wavelet transform
    Zongying Lai
    Xinlin Zhang
    Di Guo
    Xiaofeng Du
    Yonggui Yang
    Gang Guo
    Zhong Chen
    Xiaobo Qu
    [J]. BMC Medical Imaging, 18
  • [7] Fast multi-contrast MRI reconstruction
    Huang, Junzhou
    Chen, Chen
    Axel, Leon
    [J]. MAGNETIC RESONANCE IMAGING, 2014, 32 (10) : 1344 - 1352
  • [8] Multi-Image Reconstruction in Multi-Contrast MRI
    Ozbey, Muzaffer
    Cukur, Tolga
    [J]. 29TH IEEE CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS (SIU 2021), 2021,
  • [9] Fast Multi-contrast MRI Reconstruction
    Huang, Junzhou
    Chen, Chen
    Axel, Leon
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 281 - 288
  • [10] Joint Reconstruction of Multi-Contrast MRI for Multiple Sclerosis Lesion Segmentation
    Gomez, Pedro A.
    Sperl, Jonathan I.
    Sprenger, Tim
    Metzler-Baddeley, Claudia
    Jones, Derek K.
    Saemann, Philipp
    Czisch, Michael
    Menzel, Marion I.
    Menze, Bjoern H.
    [J]. BILDVERARBEITUNG FUR DIE MEDIZIN 2015: ALGORITHMEN - SYSTEME - ANWENDUNGEN, 2015, : 155 - 160