A novel integrated rotor of axial blood flow pump designed with computational fluid dynamics

被引:14
|
作者
Zhang, Yan
Xue, Song
Gui, Xing-min
Sun, Han-song
Zhang, Hao
Zhu, Xiao-dong
Hu, Sheng-shou [1 ]
机构
[1] Chinese Acad Med Sci, Res Ctr Cardiovasc Regenerat Med, Minist Hlth, Beijing 100037, Peoples R China
[2] Chinese Acad Med Sci, Cardiovasc Inst, Dept Surg, Beijing 100037, Peoples R China
[3] Chinese Acad Med Sci, Fuwai Hosp, Beijing 100037, Peoples R China
[4] Peking Union Med Coll, Beijing 100037, Peoples R China
[5] Fuwai Hosp, Dept Cardiovasc Surg, Beijing, Peoples R China
[6] Beijing Univ Aeronaut & Astronaut, Sch Jet Propuls, Beijing 100083, Peoples R China
关键词
axial/mixed blood pump; computational fluid dynamics; radial clearance; integrative rotor;
D O I
10.1111/j.1525-1594.2007.00425.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Due to the smaller size, smaller artificial surface, and higher efficiency, axial blood pumps have been widely applied in clinic in recent years. However, because of its high rotor speed, axial flow pump always has a high risk for hemolysis, which the red blood cells devastated by the shearing of tip clearance flow. We reported a novel design with the integrated blade-shroud structure that was expected to solve this problem by abolishing the radial clearance between blade and casing designed with the techniques of computational fluid dynamics (CFD). However, the numerical simulation result of the newly designed structure showed an unexpected backflow (where flow velocity is reverse of the main flow direction) at the blade tip. In order to eliminate this backflow, four flow passes were attempted, and the expansion angles (which reflect the radial amplification of the flow pass, on the meridional section, and should be defined as the angle between the center line of the flow pass and the axial direction) of the blades of the integrated rotor are 0, 8, 15, and 20, respectively. In the CFD result, it could be easily found as the expansion angles increased, the backflow was restrained gradually, and was eliminated at last. After numerous "cut and try" circles, the pump model was finally optimized. The numerical simulation of this model also showed a stable hydraulic characteristic.
引用
收藏
页码:580 / 585
页数:6
相关论文
共 50 条
  • [1] Design optimization of an axial blood pump with computational fluid dynamics
    Zhang, Yan
    Zhan, Zhao
    Gui, Xing-Min
    Sun, Han-Song
    Zhang, Hao
    Zheng, Zhe
    Zhou, Jian-Ye
    Zhu, Xiao-Dong
    Li, Guo-Rong
    Hu, Sheng-Shou
    Jin, Dong-Hai
    [J]. ASAIO JOURNAL, 2008, 54 (02) : 150 - 155
  • [2] An estimation method of hemolysis within an axial flow blood pump by computational fluid dynamics analysis
    Yano, T
    Sekine, K
    Mitoh, A
    Mitamura, Y
    Okamoto, E
    Kim, DW
    Nishimura, I
    Murabayashi, S
    Yozu, R
    [J]. ARTIFICIAL ORGANS, 2003, 27 (10) : 920 - 925
  • [3] Computational fluid dynamics of gap flow in a biocentrifugal blood pump
    Chua, LP
    Song, GL
    Yu, SCM
    Lim, TM
    [J]. ARTIFICIAL ORGANS, 2005, 29 (08) : 620 - 628
  • [4] Validation of an Axial Flow Blood Pump: Computational Fluid Dynamics Results Using Particle Image Velocimetry
    Su, Boyang
    Chua, Leok Poh
    Wang, Xikun
    [J]. ARTIFICIAL ORGANS, 2012, 36 (04) : 359 - 367
  • [5] Analysis of flow field and hemolysis index in axial flow blood pump by computational fluid dynamics–discrete element method
    Cheng, Lizhi
    Tan, Jianping
    Yun, Zhong
    Wang, Shuai
    Yu, Zheqin
    [J]. International Journal of Artificial Organs, 2021, 44 (01): : 46 - 54
  • [6] A new design and computational fluid dynamics study of an implantable axial blood pump
    Mojtaba Koochaki
    Hanieh Niroomand-Oscuii
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 417 - 422
  • [7] A new design and computational fluid dynamics study of an implantable axial blood pump
    Koochaki, Mojtaba
    Niroomand-Oscuii, Hanieh
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (04) : 417 - 422
  • [8] Shape Optimization of the Diffuser Blade of an Axial Blood Pump by Computational Fluid Dynamics
    Zhu, Lailai
    Zhang, Xiwen
    Yao, Zhaohui
    [J]. ARTIFICIAL ORGANS, 2010, 34 (03) : 185 - 192
  • [9] Computational fluid dynamics analysis of an intra-cardiac axial flow pump
    Mitoh, A
    Yano, T
    Sekine, K
    Mitamura, Y
    Okamoto, E
    Kim, DW
    Yozu, R
    Kawada, S
    [J]. ARTIFICIAL ORGANS, 2003, 27 (01) : 34 - 40
  • [10] Fluid dynamics aspects of miniaturized axial-flow blood pump
    Kang, Can
    Huang, Qifeng
    Li, Yunxiao
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 723 - 729