3D Molecular Breast Imaging Using a High-Resolution Dedicated Cardiac SPECT Camera

被引:0
|
作者
Liu, Hui [1 ]
Chan, Chung
Grobshtein, Yariv
Ma, Tianyu [1 ]
Liu, Yaqiang [1 ]
Wang, Shi [1 ]
Kench, Peter L.
Sinusas, Albert J.
Liu, Chi
机构
[1] Tsinghua Univ, Dept Engn Phys, Key Lab Particle & Radiat Imaging, Minist Educ, Beijing 100084, Peoples R China
关键词
SCINTIMAMMOGRAPHY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High-resolution dedicated cardiac SPECT systems with CZT detectors have a great potential to provide 3D molecular breast imaging of sub-cm tumors. In this study, we investigated the feasibility of breast imaging using a dedicated cardiac SPECT system (GE Discovery 530c/570c) by simulating different lesion sizes, positions, and contrasts. Noise-free NCAT phantom data with Tc-99m-tetrofosmin were simulated. The lesions diameter was 5 mm, 8 mm and 10 mm, respectively, located at the center and chest wall of both left and right breasts. Various lesion contrast levels ranging between 5:1 and 40:1 were simulated. A realistic hybrid simulation was achieved by combining the projections of a simulated 8 mm lesion and the projections of the normal left breast of a Tc-99m-Sestamibi myocardial perfusion SPECT patient at supine position. For most lesion contrasts, 10 mm-diameter and 8 mm-diameter lesions can be detected visually. However, 5 mm lesions can only be detected with high contrasts. Lesions located in the right breast were better visualized than the ones located in the left breast due to the impacts from the adjacent organs with high activity, such as the heart and liver. Lesions at the center of the breast had higher contrast than the lesions at the chest wall, which were closer to high activity organs. Higher number of iterations in the reconstruction led to improved tumor contrast, at the expense of increased non-uniformity in the background. In the hybrid simulation, the 8-mm lesion was detected clearly at the center of the breast with realistic tracer distribution in the background. The preliminary results suggest that it may be feasible to detect sub-cm breast tumors located at both central breast and chest wall using the dedicated cardiac SPECT system investigated.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] 3D spatial resolution map and sensitivity characterization of a dedicated cardiac CZT SPECT camera
    Kennedy, John
    Yosilevsky, Galina
    Przewloka, Kinga
    Israel, Ora
    Frenkel, Alex
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [2] Phantom Evaluation of a Multi-Pinhole Cardiac SPECT Camera for 3D Molecular Breast Imaging
    Tornai, Martin P.
    McDougal, Forrest A.
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [3] On the road to high-resolution 3D molecular imaging
    Delcorte, Arnaud
    [J]. APPLIED SURFACE SCIENCE, 2008, 255 (04) : 954 - 958
  • [4] 3D iteratively reconstructed spatial resolution map and sensitivity characterization of a dedicated cardiac SPECT camera
    Kennedy, John A.
    Israel, Ora
    Frenkel, Alex
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (03) : 443 - 452
  • [5] 3D iteratively reconstructed spatial resolution map and sensitivity characterization of a dedicated cardiac SPECT camera
    John A. Kennedy
    Ora Israel
    Alex Frenkel
    [J]. Journal of Nuclear Cardiology, 2014, 21 : 443 - 452
  • [6] Development of 3D HEXITEC CdZnTe detector - A large area high-resolution γ-ray imaging camera for future SPECT imaging
    Zhang, Jiajin
    Zannoni, Elena Maria
    Wilson, Matthew
    Meng, Ling-Jian
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [7] 3D Spatial resolution map, energy resolution, sensitivity, and count rate performance of a dedicated cardiac CZT SPECT camera
    Kennedy, John
    Iosilevsky, Galina
    Przewloka, Kinga
    Israel, Ora
    Frenkel, Alex
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [8] High-resolution cardiac imaging using an interleaved 3D double slab technique
    Forster, J
    Sieverding, L
    Breuer, J
    Schick, F
    Dammann, F
    Apitz, J
    Lutz, O
    [J]. MAGNETIC RESONANCE IMAGING, 1998, 16 (10) : 1155 - 1162
  • [9] 3D high-resolution cardiac collateral zone imaging by CT
    Pearlman, JD
    Laham, R
    Simons, M
    Raptopoulos, VD
    [J]. RADIOLOGY, 1997, 205 : 1354 - 1354
  • [10] HIGH-RESOLUTION DEDICATED 3D AUTOMATED BREAST ULTRASOUND WITH COMPLEMENTARY IMAGING FOR POINT-OF-CARE BREAST CANCER SCREENING
    Park, Claire
    Trumpour, Tiana
    Bax, Jeffrey
    Gyacskov, Igor
    Tessier, David
    Gardi, Lori
    Fenster, Aaron
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S40 - S41