Electrochemical Impedance-Based Biosensors for the Label-Free Detection of the Nucleocapsid Protein from SARS-CoV-2

被引:22
|
作者
Cho, Hana [1 ,2 ]
Shim, Suhyun [1 ]
Cho, Won Woo [3 ]
Cho, Sungbo [4 ]
Baek, Hanseung [5 ]
Lee, Sang-Myung [3 ]
Shin, Dong-Sik [1 ,2 ]
机构
[1] Sookmyung Womens Univ, Dept Chem & Biol Engn, Seoul 04310, South Korea
[2] Sookmyung Womens Univ, Ind Collaborat Ctr, Seoul 04310, South Korea
[3] Cantis Inc, Ansan 15588, Gyeonggi Do, South Korea
[4] Gachon Univ, Dept Elect Engn, Seongnam Si 13120, Gyeonggi Do, South Korea
[5] Purme Nexon Children Rehabil Hosp, Comprehens Dent Care Ctr, Seoul 03918, South Korea
基金
新加坡国家研究基金会;
关键词
electrochemical sensor; nucleocapsid protein; SARS-CoV-2; impedance; label-free detection; FLOW IMMUNO ASSAY; FLUORESCENCE; PCR;
D O I
10.1021/acssensors.2c00317
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Diagnosis of coronavirus disease (COVID-19) is important because of the emergence and global spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time polymerase chain reaction (PCR) is widely used to diagnose COVID-19, but it is time-consuming and requires sending samples to test centers. Thus, the need to detect antigens for rapid on-site diagnosis rather than PCR is increasing. We quantified the nucleocapsid (N) protein in SARS-CoV-2 using an electro-immunosorbent assay (El-ISA) and a multichannel impedance analyzer with a 96-interdigitated microelectrode sensor (ToAD). The El-ISA measures impedance signals from residual detection antibodies after sandwich assays and thus offers highly specific, label-free detection of the N protein with low cross-reactivity. The ToAD sensor enables the real-time electrochemical detection of multiple samples in conventional 96-well plates. The limit of detection for the N protein was 0.1 ng/mL with a detection range up to 10 ng/mL. This system did not detect signals for the S protein. While this study focused on detecting the N protein in SARS-CoV-2, our system can also be widely applicable to detecting various biomolecules involved in antigen-antibody interactions.
引用
收藏
页码:1676 / 1684
页数:9
相关论文
共 50 条
  • [1] Label-free and reagent-less electrochemical detection of nucleocapsid protein of SARS-CoV-2: an ultrasensitive and disposable biosensor
    Aydin, Elif Burcu
    Aydin, Muhammet
    Sezginturk, Mustafa Kemal
    [J]. NEW JOURNAL OF CHEMISTRY, 2022, 46 (19) : 9172 - 9183
  • [2] Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector
    Rashed, Mohamed Z.
    Kopechek, Jonathan A.
    Priddy, Mariah C.
    Hamorsky, Krystal T.
    Palmer, Kenneth E.
    Mittal, Nikhil
    Valdez, Joseph
    Flynn, Joseph
    Williams, Stuart J.
    [J]. Biosensors and Bioelectronics, 2021, 171
  • [3] Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector
    Rashed, Mohamed Z.
    Kopechek, Jonathan A.
    Priddy, Mariah C.
    Hamorsky, Krystal T.
    Palmer, Kenneth E.
    Mittal, Nikhil
    Valdez, Joseph
    Flynn, Joseph
    Williams, Stuart J.
    [J]. BIOSENSORS & BIOELECTRONICS, 2021, 171
  • [4] Automatic label-free immunoassay with high sensitivity for rapid detection of SARS-CoV-2 nucleocapsid protein based on chemiluminescent magnetic beads
    Lyu, Aihua
    Jin, Tengchuan
    Wang, Shanshan
    Huang, Xiaoxue
    Zeng, Weihong
    Yang, Rui
    Cui, Hua
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2021, 349
  • [5] Rapid Detection of SARS-CoV-2 Nucleocapsid Protein by a Label-Free Biosensor Based on Optical Fiber Cylindrical Micro-Resonator
    Xia, Ru-Lei
    Liu, Bin
    Hu, Yingying
    Liu, Juan
    Fu, Yue
    He, Xing-Dao
    Lu, Ping
    Farrell, Gerald
    Yuan, Jinhui
    Wu, Qiang
    [J]. IEEE SENSORS JOURNAL, 2023, 23 (12) : 12511 - 12518
  • [6] PCR- and label-free SARS-CoV-2 electrochemical immunosensor
    Vasquez, Viviana
    Orozco, Jahir
    [J]. MICROCHEMICAL JOURNAL, 2023, 193
  • [7] A self-enhanced electrochemiluminescence array chip for portable label-free detection of SARS-CoV-2 nucleocapsid protein with smartphone
    Nie, Wei
    Zhang, Ruoxian
    Hu, Chao
    Jin, Tengchuan
    Wei, Xi
    Cui, Hua
    [J]. BIOSENSORS & BIOELECTRONICS, 2023, 240
  • [8] Electrochemical Biosensors for SARS-CoV-2 Detection
    Andrianova M.S.
    Panova O.S.
    Titov A.A.
    Komarova N.V.
    Kuznetsov A.E.
    [J]. Moscow University Chemistry Bulletin, 2023, 78 (5) : 231 - 254
  • [9] Label-free electrochemical aptasensor for the detection of SARS-CoV-2 spike protein based on carbon cloth sputtered gold nanoparticles
    Adeel, Muhammad
    Asif, Kanwal
    Alshabouna, Fahad
    Canzonieri, Vincenzo
    Rahman, Md. Mahbubur
    Ansari, Sajid Ali
    Güder, Firat
    Rizzolio, Flavio
    Daniele, Salvatore
    [J]. Biosensors and Bioelectronics: X, 2022, 12
  • [10] Recent Advances in Field-Effect Transistor-Based Biosensors for Label-Free Detection of SARS-CoV-2
    Yu, Haiyang
    Zhang, Huibin
    Liu, Zhe
    Feng, Linrun
    Su, Yuezeng
    Li, Jinhua
    Tang, Wei
    Yan, Feng
    [J]. SMALL SCIENCE, 2024, 4 (02):