Effect of vapor condensation on forced convection heat transfer of moistened gas

被引:55
|
作者
Liang, Yongbin [1 ]
Che, Defu [1 ]
Kang, Yanbin [1 ]
机构
[1] Xian Jiaotong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
关键词
D O I
10.1007/s00231-006-0148-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
The forced convection heat transfer with water vapor condensation is studied both theoretically and experimentally when wet flue gas passes downwards through a bank of horizontal tubes. Extraordinarily, discussions are concentrated on the effect of water vapor condensation on forced convection heat transfer. In the experiments, the air-steam mixture is used to simulate the flue gas of a natural gas fired boiler, and the vapor mass fraction ranges from 3.2 to 12.8%. By theoretical analysis, a new dimensionless number defined as augmentation factor is derived to account for the effect of condensation of relatively small amount of water vapor on convection heat transfer, and a consequent correlation is proposed based on the experimental data to describe the combined convection-condensation heat transfer. Good agreement can be found between the values of the Nusselt number obtained from the experiments and calculated by the correlation. The maximum deviation is within +/- 6%. The experimental results also shows that the convection-condensation heat transfer coefficient increases with Reynolds number and bulk vapor mass fraction, and is 1 similar to 3.5 times that of the forced convection without condensation.
引用
收藏
页码:677 / 686
页数:10