Comparison of organ and effective dose estimations from different Monte Carlo simulation-based software methods in infant CT and comparison with direct phantom measurements

被引:6
|
作者
Lawson, Michael [1 ,2 ]
Berk, Kemal [3 ]
Badawy, Mohamed [1 ,4 ]
Qi, Yujin [2 ]
Kuganesan, Ahilan [1 ]
Metcalfe, Peter [2 ]
机构
[1] Monash Hlth, Monash Hlth Imaging, Clayton, Vic 3168, Australia
[2] Univ Wollongong, Fac Engn & Informat Sci, Ctr Med Radiat Phys, Sch Phys, Wollongong, NSW, Australia
[3] Peter MacCallum Canc Ctr, Dept Phys Sci, Melbourne, Vic, Australia
[4] Monash Univ, Dept Med Imaging & Radiat Sci, Sch Primary & Allied Hlth Care, Fac Med Nursing & Hlth Sci, Clayton, Vic, Australia
来源
关键词
computational dosimetry; computed tomography; effective dose; infants; organ dose; thermoluminescent dosimeters; BONE-MARROW; DOSIMETRY; PROTOCOL; NEWBORN; PATIENT; PROGRAM;
D O I
10.1002/acm2.13625
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Computational dosimetry software is routinely used to evaluate the organ and effective doses from computed tomography (CT) examinations. Studies have shown a significant variation in dose estimates between software in adult cohorts, and few studies have evaluated software for pediatric dose estimates. This study aims to compare the primary organ and effective doses estimated by four commercially available CT dosimetry software to thermoluminescent dosimeter (TLD) measurements in a 1-year-old phantom. Methods One hundred fifteen calibrated LiF (Mg, Cu, P)-TLD 100-H chips were embedded within an anthropomorphic phantom representing a 1-year-old child at positions that matched the approximate location of organs within an infant. The phantom was scanned under three protocols, each with whole-body coverage. The mean absorbed doses from 25 radiosensitive organs and skeletal tissues were determined from the TLD readings. Effective doses for each of the protocols were subsequently calculated using ICRP 103 formalism. Dose estimates by the four Monte Carlo-based dose calculation systems were determined and compared to the directly measured doses. Results Most organ doses determined by computation dosimetry software aligned to phantom measurements within 20%. Additionally, comparisons between effective doses are calculated using computational and direct measurement methods aligned within 20% across the three protocols. Significant variances were found in bone surface dose estimations among dosimetry methods, likely caused by differences in bone tissue modeling. Conclusion All four-dosimetry software evaluated in this study provide adequate primary organ and effective dose estimations. Users should be aware, however, of the possible estimated uncertainty associated with each of the programs.
引用
收藏
页数:12
相关论文
共 17 条
  • [1] Evaluating Effective Dose: A Comparison of Methods Based on Organ Dose Calculations versus Dose-Length Product and Monte Carlo Simulation
    Abuelhia, Elfatih
    Tajaldeen, Abdulrahman
    Alghamdi, Ali
    Mabrouk, Osama
    Aluraik, Wejdan
    Msmar, Amir
    Elsadig, Muawia
    Osman, Entisar
    Al-Othman, Abdullah
    Alghamdi, Salem
    Albadri, Mesbah
    Aljondi, Rowa
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [2] Typical exposure parameters, organ doses and effective doses for endovascular aortic aneurysm repair: Comparison of Monte Carlo simulations and direct measurements with an anthropomorphic phantom
    Foerth, Monika
    Seidenbusch, Michael C.
    Sadeghi-Azandaryani, Mojtaba
    Lechel, Ursula
    Treitl, Karla Maria
    Treitl, Marcus
    EUROPEAN RADIOLOGY, 2015, 25 (09) : 2617 - 2626
  • [3] Typical exposure parameters, organ doses and effective doses for endovascular aortic aneurysm repair: Comparison of Monte Carlo simulations and direct measurements with an anthropomorphic phantom
    Monika Foerth
    Michael C. Seidenbusch
    Mojtaba Sadeghi-Azandaryani
    Ursula Lechel
    Karla Maria Treitl
    Marcus Treitl
    European Radiology, 2015, 25 : 2617 - 2626
  • [4] Comparison of the Batho, ETAR and Monte Carlo dose calculation methods in CT based patient models
    du Plessis, FCP
    Willemse, CA
    Lötter, MG
    Goedhals, L
    MEDICAL PHYSICS, 2001, 28 (04) : 582 - 589
  • [5] Determination of dose from CT examinations: Estimating organ dose using Monte Carlo-based methods
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2538 - 2539
  • [6] Verification of organ doses calculated by a dose monitoring software tool based on Monte Carlo Simulation in thoracic CT protocols
    Guberina, Nika
    Suntharalingam, Saravanabavaan
    Nassenstein, Kai
    Forsting, Michael
    Theysohn, Jens
    Wetter, Axel
    Ringelstein, Adrian
    ACTA RADIOLOGICA, 2018, 59 (03) : 322 - 326
  • [7] Evaluation of Organ Doses for Pediatric Computed Tomography Using a Newly Designed Radiophotoluminescence Glass Dosimeter and Comparison with a Monte Carlo Simulation-based Dose Calculator
    Chang, Weishan
    Koba, Yusuke
    HEALTH PHYSICS, 2021, 120 (03): : 288 - 295
  • [8] Monte Carlo simulation of eye lens dose reduction from CT scan using organ based tube current modulation
    Huang, Ying
    Zhuo, Weihai
    Gao, Yiming
    Liu, Haikuan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 48 : 72 - 75
  • [9] Comparison of Organ and Effective Dose Estimates for CT Exams Obtained from Two Commercially Available Radiation Dose Monitoring Software (RDMS) Systems
    Bostani, M.
    Cagnon, C.
    Oshiro, T.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E489 - E489
  • [10] Comparison of patient effective doses from multiple CT examinations based on different calculation methods
    Avramova-Cholakova, Simona
    Dyakov, Iliya
    Yordanov, Hristomir
    O'Sullivan, James
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 99 : 73 - 84