An improved protocol for the production of AFLP™ markers in complex genomes by means of capillary electrophoresis

被引:48
|
作者
Papa, R
Troggio, M
Ajmone-Marsan, P
Nonnis Marzano, F [1 ]
机构
[1] Univ Parma, Dipartimento Biol Evolut & Funz, I-43100 Parma, Italy
[2] Univ Parma, Dipartimento Sci Ambientali, I-43100 Parma, Italy
[3] Univ Cattolica Sacro Cuore, Ist Zootecn, Piacenza, Italy
关键词
D O I
10.1111/j.1439-0388.2004.00476.x
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The amplified fragment-length polymorphism (AFLP) technology is a recently introduced method to investigate genomes of different complexity, from microbial to higher organisms. It is applied to purposes as diverse as identification of species, strain and varieties, investigation of genetic diversity within and between populations, simple and complex trait mapping, and construction of linkage and physical maps. This technology has been designed on the use of primers labelled with radioactivity and on AFLP fragment separation on sequencing gel. We show that the original EcoRI/TaqI AFLP protocol does not perform appropriately when transferred to fluorescent labelling and capillary electrophoresis (CE), and propose an improved protocol for the production of high-quality AFLP markers in fish, rodents and artiodactyles by means of the Beckman-Coulter CEQ2000 automatic DNA sequencer. In addition, we describe the procedure routinely used in our laboratory to obtain binary matrices from AFLP profiles with the aid of Genographer free-share software (vers. 1.6.0, J.J. Benham, Montana State University), able to elaborate original fragment data and convert them to standard graphical formats for phylogenetic analyses. Comparison with radioactive AFLPs in goats confirmed the reliability of the protocol developed for CE. In fact, 107 fragments generated by two primer combinations and identified by both techniques were attributed the same scoring. Compared with traditional methods, the use of capillary systems and automated analysis increases data throughput and scoring reliability, decreasing the overall experimental error.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 9 条
  • [1] An efficient and reproducible protocol for production of AFLP markers in tree genomes using fluorescent capillary detection
    Hasbun, Rodrigo
    Iturra, Carolina
    Moraga, Priscila
    Wachtendorff, Pamela
    Quiroga, Pamela
    Valenzuela, Sofia
    TREE GENETICS & GENOMES, 2012, 8 (04) : 925 - 931
  • [2] An efficient and reproducible protocol for production of AFLP markers in tree genomes using fluorescent capillary detection
    Rodrigo Hasbún
    Carolina Iturra
    Priscila Moraga
    Pamela Wachtendorff
    Pamela Quiroga
    Sofía Valenzuela
    Tree Genetics & Genomes, 2012, 8 : 925 - 931
  • [3] Cloning of AFLP markers detected by fluorescence capillary electrophoresis
    Carlos Polanco
    Ana I. González
    Raúl de la Puente
    Sergio Somalo
    María L. Ruiz
    Plant Molecular Biology Reporter, 2005, 23 : 271 - 277
  • [4] Cloning of AFLP markers detected by fluorescence capillary electrophoresis
    Polanco, C
    González, AI
    de la Puente, R
    Somalo, S
    Ruiz, ML
    PLANT MOLECULAR BIOLOGY REPORTER, 2005, 23 (03) : 271 - 277
  • [5] An optimized protocol for the production of interdelta markers in Saccharomyces cerevisiae by using capillary electrophoresis
    Tristezza, Mariana
    Gerardi, Carmela
    Logrieco, Antonio
    Grieco, Francesco
    JOURNAL OF MICROBIOLOGICAL METHODS, 2009, 78 (03) : 286 - 291
  • [6] Improved AFLP protocol using dual-suppression PCR and its application to species with large genomes
    Guan, Lanhua
    Shiraishi, Susumu
    MOLECULAR ECOLOGY RESOURCES, 2011, 11 (05) : 854 - 861
  • [7] Enantioselective recognition of sutezolid by cyclodextrin modified non-aqueous capillary electrophoresis and explanation of complex formation by means of infrared spectroscopy, NMR and molecular modelling
    Michalska, Katarzyna
    Bocian, Wojciech
    Bednarek, Elzbieta
    Palys, Barbara
    Cielecka-Piontek, Judyta
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 169 : 49 - 59
  • [8] Third-Generation Electrokinetically Pumped Sheath-Flow Nanospray Interface with Improved Stability and Sensitivity for Automated Capillary Zone Electrophoresis-Mass Spectrometry Analysis of Complex Proteome Digests
    Sun, Liangliang
    Zhu, Guijie
    Zhang, Zhenbin
    Mou, Si
    Dovichi, Norman J.
    JOURNAL OF PROTEOME RESEARCH, 2015, 14 (05) : 2312 - 2321
  • [9] Detachable Strong Cation Exchange Monolith, Integrated with Capillary Zone Electrophoresis and Coupled with pH Gradient Elution, Produces Improved Sensitivity and Numbers of Peptide Identifications during Bottom-up Analysis of Complex Proteomes
    Zhang, Zhenbin
    Yan, Xiaojing
    Sun, Liangliang
    Zhu, Guijie
    Dovichi, Norman J.
    ANALYTICAL CHEMISTRY, 2015, 87 (08) : 4572 - 4577