AO tension-band osteosynthesis of displaced olecranon fractures

被引:0
|
作者
Finsen, V [1 ]
Lingaas, PS [1 ]
Storro, S [1 ]
机构
[1] Univ Trondheim Hosp, Dept Orthoped Surg, N-7006 Trondheim, Norway
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study reviewed 31 patients who underwent AO tension-band osteosynthesis of displaced olecranon fractures. Thirteen fractures were comminuted. Postoperative immobilization was short, and the median hospital stay was 3 days. In 2 patients, the stainless steel wire broke and required replacement. In 13 patients, the osteosynthesis material was removed after healing because of pain at the tip of the elbow; this did not influence the final result. Median time out of work was 12 weeks. There was no significant loss of elbow power. There was satisfactory mobility, function, and absence of pain. There were 29 good and 2 fair clinical results. Anatomic reduction was achieved in 24 elbows. Possible arthrosis was detected at follow-up in 5 elbows but these patients had a good clinical result. AO tension-band osteosynthesis of displaced olecranon fractures yields good clinical medium-term results with few serious complications.
引用
收藏
页码:1069 / 1072
页数:4
相关论文
共 50 条
  • [2] OSTEOSYNTHESIS BY TENSION BAND WIRING OF DISPLACED FRACTURES OF THE OLECRANON
    DOURSOUNIAN, L
    PREVOT, O
    TOUZARD, RC
    ANNALES DE CHIRURGIE, 1994, 48 (02): : 169 - 177
  • [3] COMPLICATIONS OF TENSION-BAND WIRING OF OLECRANON FRACTURES
    MACKO, D
    SZABO, RM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (09): : 1396 - 1401
  • [4] TENSION-BAND WIRE FIXATION OF OLECRANON FRACTURES
    Carter, Tom H.
    Molyneux, Samuel G.
    Reid, Jeffrey T.
    White, Timothy O.
    Duckworth, Andrew D.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2018, 8 (03):
  • [5] BIOMECHANICAL ASSESSMENT OF TENSION-BAND WIRING FOR OLECRANON FRACTURES
    Kuo, Chien-Chung
    Hsu, Horng-Chaung
    Hong, Shih-Wun
    Lu, Tung-Wu
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2011, 23 (01): : 83 - 87
  • [6] TENSION-BAND WIRING TECHNIQUE FOR TREATMENT OF OLECRANON FRACTURES
    WEISBAND, ID
    JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION, 1978, 77 (05): : 390 - 392
  • [7] Tension-band wiring of displaced stable olecranon fractures with Eyelet-pins in the elderly: A series of 17 cases
    Tsujino, Shohei
    Tsujino, Akihito
    Matsubara, Masaaki
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (08)
  • [8] Tension-band wiring for olecranon fractures: Analysis of risk factors for failure
    Villanueva, Patricia
    Osorio, Fernando
    Commessatti, Mateo
    Sanchez-Sotelo, Joaquin
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (03) : 351 - 356
  • [9] TENSION-BAND FIXATION OF OLECRANON FRACTURES - A CADAVER STUDY OF ELBOW EXTENSION
    COLEMAN, NP
    WARREN, PJ
    ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (01): : 58 - 59
  • [10] TENSION BAND WIRING OF OLECRANON FRACTURES - A MODIFICATION OF THE AO TECHNIQUE
    ROWLAND, SA
    BURKHART, SS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (277) : 238 - 242