Extracellular Vesicle Surface Signatures in IPF Patients: A Multiplex Bead-Based Flow Cytometry Approach

被引:20
|
作者
d'Alessandro, Miriana [1 ]
Soccio, Piera [2 ,3 ]
Bergantini, Laura [1 ]
Cameli, Paolo [1 ]
Scioscia, Giulia [2 ,3 ]
Foschino Barbaro, Maria Pia [2 ,3 ]
Lacedonia, Donato [2 ,3 ]
Bargagli, Elena [1 ]
机构
[1] Siena Univ Hosp, Dept Med & Surg Sci & Neurosci, Resp Dis Unit, I-53100 Siena, Italy
[2] Univ Foggia, Dept Med & Surg Sci, I-71122 Foggia, Italy
[3] Policlin Riuniti Foggia, Inst Resp Dis, I-71122 Foggia, Italy
关键词
extracellular vesicles; IPF; biomarkers; prognosis; IDIOPATHIC PULMONARY-FIBROSIS; T-CELL PROLIFERATION; STEM-CELLS; SERUM; ACTIVATION; SOCIETY; BIOLOGY; BINDING; INJURY;
D O I
10.3390/cells10051045
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Background: Extracellular vesicles (EVs) are secreted by cells from their membrane within circulation and body fluids. Knowledge of the involvement of EVs in pathogenesis of lung diseases is increasing. The present study aimed to evaluate the expression of exosomal surface epitopes in a cohort of idiopathic pulmonary fibrosis (IPF) patients followed in two Italian Referral Centres for Interstitial Lung Diseases, comparing them with a group of healthy volunteers. Materials and Methods: Ninety IPF patients (median age and interquartile range (IQR) 71 (66-75) years; 69 males) were selected retrospectively. Blood samples were obtained from patients before starting antifibrotic therapy. A MACSPlex Exosome Kit, human, (Miltenyi Biotec, Bergisch-Gladbach, Germany), to detect 37 exosomal surface epitopes, was used. Results: CD19, CD69, CD8, and CD86 were significantly higher in IPF patients than in controls (p = 0.0023, p = 0.0471, p = 0.0082, and p = 0.0143, respectively). CD42a was lower in IPF subjects than in controls (p = 0.0153), while CD209, Cd133/1, MCSP, and ROR1 were higher in IPF patients than in controls (p = 0.0007, p = 0.0050, p = 0.0139, and p = 0.0335, respectively). Kaplan-Meier survival analysis for IPF patients: for median values and a cut-off of 0.48 for CD25, the two subgroups showed a significant difference in survival rate (p = 0.0243, hazard ratio: 0.52 (95%CI 0.29-0.92); the same was true for CD8 (cut-off 1.53, p = 0.0309, hazard ratio: 1.39 (95%CI 0.75-2.53). Conclusion: Our multicenter study showed for the first time the expression of surface epitopes on EVs from IPF patients, providing interesting data on the communication signatures/exosomal profile in serum from IPF patients and new insights into the pathogenesis of the disease and a promising reliability in predicting mid-term survival of IPF patients.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Systematic Methodological Evaluation of a Multiplex Bead-Based Flow Cytometry Assay for Detection of Extracellular Vesicle Surface Signatures
    Wiklander, Oscar P. B.
    Bostancioglu, R. Beklem
    Welsh, Joshua A.
    Zickler, Antje M.
    Murke, Florian
    Corso, Giulia
    Felldin, Ulrika
    Hagey, Daniel W.
    Evertsson, Bjorn
    Liang, Xiu-Ming
    Gustafsson, Manuela O.
    Mohammad, Dara K.
    Wiek, Constanze
    Hanenberg, Helmut
    Bremer, Michel
    Gupta, Dhanu
    Bjornstedt, Mikael
    Giebel, Bernd
    Nordin, Joel Z.
    Jones, Jennifer C.
    EL Andaloussi, Samir
    Goergens, Andre
    FRONTIERS IN IMMUNOLOGY, 2018, 9
  • [2] Bead-Based Extracellular Vesicle Analysis Using Flow Cytometry
    Yang, Katherine S.
    Lin, Hsing-Ying
    Curley, Caleigh
    Welch, Marisa W.
    Wolpin, Brian M.
    Lee, Hakho
    Weissleder, Ralph
    Im, Hyungsoon
    Castro, Cesar M.
    ADVANCED BIOSYSTEMS, 2020, 4 (12)
  • [3] Description and optimization of a multiplex bead-based flow cytometry method (MBFCM) to characterize extracellular vesicles in serum samples from patients with hematological malignancies
    Li, Lin
    Gorgens, Andre
    Mussack, Veronika
    Pepeldjiyska, Elena
    Hartz, Anne Sophie
    Rank, Andreas
    Schmohl, Jorg
    Kra''mer, Doris
    Andaloussi, Samir El
    Pfaffl, Michael W.
    Schmetzer, Helga
    CANCER GENE THERAPY, 2022, 29 (11) : 1600 - 1615
  • [4] Description and optimization of a multiplex bead-based flow cytometry method (MBFCM) to characterize extracellular vesicles in serum samples from patients with hematological malignancies
    Lin Li
    André Görgens
    Veronika Mussack
    Elena Pepeldjiyska
    Anne Sophie Hartz
    Andreas Rank
    Jörg Schmohl
    Doris Krämer
    Samir El Andaloussi
    Michael W. Pfaffl
    Helga Schmetzer
    Cancer Gene Therapy, 2022, 29 : 1600 - 1615
  • [5] Development of a Bead-Based Multiplex Assay for the Simultaneous Quantification of Three Staphylococcal Enterotoxins in Food by Flow Cytometry
    Shepelyakovskaya, Anna
    Rudenko, Natalia
    Karatovskaya, Anna
    Shchannikova, Margarita
    Shulcheva, Irina
    Fursova, Ksenia
    Zamyatina, Anna
    Boziev, Khanafi
    Oleinikov, Vladimir
    Brovko, Fedor
    FOOD ANALYTICAL METHODS, 2020, 13 (05) : 1202 - 1210
  • [6] Development of a Bead-Based Multiplex Assay for the Simultaneous Quantification of Three Staphylococcal Enterotoxins in Food by Flow Cytometry
    Anna Shepelyakovskaya
    Natalia Rudenko
    Anna Karatovskaya
    Margarita Shchannikova
    Irina Shulcheva
    Ksenia Fursova
    Anna Zamyatina
    Khanafi Boziev
    Vladimir Oleinikov
    Fedor Brovko
    Food Analytical Methods, 2020, 13 : 1202 - 1210
  • [7] A Combined Western and Bead-Based Multiplex Platform to Characterize Extracellular Vesicles
    van Maanen, Josette C.
    Bach, Frances C.
    Braun, Theresa S.
    Giovanazzi, Alberta
    van Balkom, Bas W. M.
    Templin, Markus
    Wauben, Marca H. M.
    Tryfonidou, Marianna A.
    TISSUE ENGINEERING PART C-METHODS, 2023, 29 (11) : 493 - 504
  • [8] A novel multiplex bead-based platform highlights the diversity of extracellular vesicles
    Koliha, Nina
    Wiencek, Yvonne
    Heider, Ute
    Juengst, Christian
    Kladt, Nikolay
    Krauthaeuser, Susanne
    Johnston, Ian C. D.
    Bosio, Andreas
    Schauss, Astrid
    Wild, Stefan
    JOURNAL OF EXTRACELLULAR VESICLES, 2016, 5
  • [9] Identification of a Small GTPase Inhibitor Using a High-Throughput Flow Cytometry Bead-Based Multiplex Assay
    Surviladze, Zurab
    Waller, Anna
    Wu, Yang
    Romero, Elsa
    Edwards, Bruce S.
    Wandinger-Ness, Angela
    Sklar, Larry A.
    JOURNAL OF BIOMOLECULAR SCREENING, 2010, 15 (01) : 10 - 20
  • [10] Lifetime encoding in flow cytometry for bead-based sensing of biomolecular interaction
    Daniel Kage
    Katrin Hoffmann
    Heike Borcherding
    Uwe Schedler
    Ute Resch-Genger
    Scientific Reports, 10