Direct Detection of DNA and RNA on Carbon Fiber Microelectrodes Using Fast-Scan Cyclic Voltammetry

被引:10
|
作者
Asrat, Thomas M. [1 ]
Cho, Whirang [1 ]
Liu, Favian A. [1 ]
Shapiro, Sarah M. [2 ]
Bracht, John R. [2 ]
Zestos, Alexander G. [1 ]
机构
[1] Amer Univ, Dept Chem, Washington, DC 20016 USA
[2] Amer Univ, Dept Biol, Washington, DC 20016 USA
来源
ACS OMEGA | 2021年 / 6卷 / 10期
基金
美国安德鲁·梅隆基金会;
关键词
WAVE-FORM; DOPAMINE; ADENINE; GUANINE; PYRIMIDINES; CYTOSINE; PURINES; THYMINE; SENSORS; ADSORPTION;
D O I
10.1021/acsomega.0c04845
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
DNA and RNA have been measured with many techniques but often with relatively long analysis times. In this study, we utilize fast-scan cyclic voltammetry (FSCV) for the subsecond codetection of adenine, guanine, and cytosine, first as free nucleosides, and then within custom synthesized oligos, plasmid DNA, and RNA from the nematode Caenorhabditis elegans. Previous studies have shown the detection of adenosine and guanosine with FSCV with high spatiotemporal resolution, while we have extended the assay to include cytidine and adenine, guanine, and cytosine in RNA and single- and double-stranded DNA (ssDNA and dSDNA). We find that FSCV testing has a higher sensitivity and yields higher peak oxidative currents when detecting shorter oligonucleotides and ssDNA samples at equivalent nucleobase concentrations. This is consistent with an electrostatic repulsion from negatively charged oxide groups on the surface of the carbon fiber microelectrode (CFME), the negative holding potential, and the negatively charged phosphate backbone. Moreover, as opposed to dsDNA, ssDNA nucleobases are not hydrogen-bonded to one another and thus are free to adsorb onto the surface of the carbon electrode. We also demonstrate that the simultaneous determination of nucleobases is not masked even in biologically complex serum samples. This is the first report demonstrating that FSCV, when used with CFMEs, is able to codetect nucleobases when polymerized into DNA or RNA and could potentially pave the way for future uses in clinical, diagnostic, or research applications.
引用
收藏
页码:6571 / 6581
页数:11
相关论文
共 50 条
  • [1] Ultrafast Detection of Arsenic Using Carbon-Fiber Microelectrodes and Fast-Scan Cyclic Voltammetry
    Manring, Noel
    Strini, Miriam
    Koifman, Gene
    Xavier, Jonathan
    Smeltz, Jessica L.
    Pathirathna, Pavithra
    MICROMACHINES, 2024, 15 (06)
  • [2] The measurement of phenols with graphitic carbon fiber microelectrodes and fast-scan cyclic voltammetry
    Abdullaeva, Cam
    Alyamni, Nadiah
    Jessen-Hegelbach, Jackie
    Zestos, Alexander G.
    NANOTECHNOLOGY, 2025, 36 (10)
  • [3] Electrochemical Properties of Different Carbon-Fiber Microelectrodes Using Fast-Scan Cyclic Voltammetry
    Huffman, Megan L.
    Venton, B. Jill
    ELECTROANALYSIS, 2008, 20 (22) : 2422 - 2428
  • [4] Plasma-treated carbon-fiber microelectrodes for improved purine detection with fast-scan cyclic voltammetry
    Li, Yuxin
    Ross, Ashley E.
    ANALYST, 2020, 145 (03) : 805 - 815
  • [5] Amine-functionalized carbon-fiber microelectrodes for enhanced ATP detection with fast-scan cyclic voltammetry
    Li, Yuxin
    Weese, Moriah E.
    Cryan, Michael T.
    Ross, Ashley E.
    ANALYTICAL METHODS, 2021, 13 (20) : 2320 - 2330
  • [6] Multiplexing neurochemical detection with carbon fiber multielectrode arrays using fast-scan cyclic voltammetry
    Harmain Rafi
    Alexander G. Zestos
    Analytical and Bioanalytical Chemistry, 2021, 413 : 6715 - 6726
  • [7] Multiplexing neurochemical detection with carbon fiber multielectrode arrays using fast-scan cyclic voltammetry
    Rafi, Harmain
    Zestos, Alexander G.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (27) : 6715 - 6726
  • [8] Characterization of Local pH Changes in Brain Using Fast-Scan Cyclic Voltammetry with Carbon Microelectrodes
    Takmakov, Pavel
    Zachek, Matthew K.
    Keithley, Richard B.
    Bucher, Elizabeth S.
    McCarty, Gregory S.
    Wightman, R. Mark
    ANALYTICAL CHEMISTRY, 2010, 82 (23) : 9892 - 9900
  • [9] Overoxidized polypyrrole-coated carbon fiber microelectrodes for dopamine measurements with fast-scan cyclic voltammetry
    Pihel, K
    Walker, QD
    Wightman, RM
    ANALYTICAL CHEMISTRY, 1996, 68 (13) : 2084 - 2089
  • [10] Electrodeposition of dopamine onto carbon fiber microelectrodes to enhance the detection of Cu2+ via fast-scan cyclic voltammetry
    Manring, Noel
    Ahmed, Muzammil M. N.
    Smeltz, Jessica L.
    Pathirathna, Pavithra
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (18) : 4289 - 4296