Influence of smooth, 1st derivative and baseline correction on the near-infrared spectrum analysis with PLS

被引:0
|
作者
Zheng, YM [1 ]
Zhang, TQ
Zhang, J
Chen, XD
Shen, XG
机构
[1] Jilin Univ, Phys Coll, Changchun 130025, Peoples R China
[2] Changchun Inst Opt Fine Mech & Phys, Changchun 130022, Peoples R China
关键词
smooth; 1st derivative; baseline correction; near-infrared; PLS; quantitative analysis;
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This paper studied the influence of using pre-procession such as smooth, 1st derivative and baseline correction on the analysis of near-infrared spectrum. Comparing the analysis results by the pre-procession methods, and using PLS arithmetic, the best pre-procession was determined. In smooth pre-procession method, the best smooth points were proposed for regression using PLS. The analysis result is satisfactory.
引用
收藏
页码:1546 / 1548
页数:3
相关论文
共 2 条
  • [1] LU WT, 2001, MODERN ANAL TECHNIQ
  • [2] Pu R., 2000, Hyperspectral Remote Sensing and Its Applications