Effects of the magnetic field on the freezing parameters of the pork

被引:51
|
作者
Tang, Junyan [1 ,2 ,3 ]
Shao, Shuangquan [1 ,2 ]
Tian, Changqing [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, CAS Key Lab Cryogen, Beijing, Peoples R China
[2] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing Key Lab Thermal Sci & Technol, Beijing, Peoples R China
[3] Univ Chinese Acad Sci, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Permanent magnetic field; Alternating magnetic field; Freezing parameters; Magnetic field intensity; Food quality; PROGRAMMED FREEZER; ELECTRIC-FIELD; COMBINATION TECHNOLOGY; AIR BLAST; FOOD; CRYOPRESERVATION; WATER; TEMPERATURE; KINETICS; MEAT;
D O I
10.1016/j.ijrefrig.2019.07.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, we investigated the effect of the different magnetic field type and intensity on the freezing process of pork samples. The permanent magnetic field (PMF) and the alternating magnetic field (AMF) with the intensity varied from 0.00 mT to 16.00 mT and 0.00 mT to 1.80 mT respectively were applied on the pork samples when they were freezing to -30 degrees C at the freezing rate of 4 degrees C/min. Five parameters including the nucleation temperature, freezing temperature, time through -1 degrees C to -5 degrees C, phase change time and subcooling time were chosen to evaluate the freezing effects. The results showed that all the freezing parameters except the freezing temperature were significantly different with PMF (p < 0.05). The nucleation point, phase change time and subcooling time decreased 2.79 degrees C, 1.76 min and 0.80 min respectively with the PMF intensity of 15.98 mT, while the time through -1 degrees C to -5 degrees C increased slightly. The nucleation temperature and time through -1 degrees C to -5 degrees C of the pork sample were not significantly different (p > 0.05) with AMF. The freezing temperature and phase change time decreased slightly and the subcooling time was similar to PMF. In addition, the whole freezing time was longer with AMF than PMF which would need more energy. So PMF may be a promising method for the higher food quality and less energy consumption. Take all the factors into consideration, 15.98 mT may be the optimal magnetic field intensity for PMF. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 50 条
  • [1] Pork Freezing and Quality Improvement: The Effect of Immersion Freezing Assisted By Magnetic Field
    Sunlong Gan
    Min Zhang
    Qiyong Jiang
    Food and Bioprocess Technology, 2024, 17 : 73 - 82
  • [2] Pork Freezing and Quality Improvement: The Effect of Immersion Freezing Assisted By Magnetic Field
    Gan, Sunlong
    Zhang, Min
    Jiang, Qiyong
    FOOD AND BIOPROCESS TECHNOLOGY, 2024, 17 (01) : 73 - 82
  • [3] Effects of Weak Oscillating Magnetic Fields on the Freezing of Pork Loin
    Rodriguez, Antonio C.
    James, Christian
    James, Stephen J.
    FOOD AND BIOPROCESS TECHNOLOGY, 2017, 10 (09) : 1615 - 1621
  • [4] Effects of Weak Oscillating Magnetic Fields on the Freezing of Pork Loin
    Antonio C. Rodríguez
    Christian James
    Stephen J. James
    Food and Bioprocess Technology, 2017, 10 : 1615 - 1621
  • [5] Effects of the magnetic field on the freezing process of blueberry
    Tang, Junyan
    Shao, Shuangquan
    Tian, Changqing
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 113 : 288 - 295
  • [6] Effects of different magnetic fields on the freezing parameters of cherry
    Tang, Junyan
    Zhang, Hainan
    Tian, Changqing
    Shao, Shuangquan
    JOURNAL OF FOOD ENGINEERING, 2020, 278
  • [7] The effect of freezing and thawing on the magnetic resonance imaging parameters of water in beef, lamb and pork meat
    Evans, SD
    Nott, KP
    Kshirsagar, AA
    Hall, LD
    INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 1998, 33 (03): : 317 - 328
  • [8] Effect of Magnetic Field Assisted Freezing on the Properties and Quality Characteristics of Myofibrillar Protein in Prepared Pork
    Li, Yuhao
    Tao, Yingmei
    Lei, Yu
    Deng, Mengsheng
    Li, Tian
    Jin, Lei
    Li, Dong
    Science and Technology of Food Industry, 2024, 45 (23) : 76 - 83
  • [9] Effects of high-voltage electrostatic field on the freezing behavior and quality of pork tenderloin
    Jia, Guoliang
    He, Xiangli
    Nirasawa, Satoru
    Tatsumi, Eizo
    Liu, Hongjiang
    Liu, Haijie
    JOURNAL OF FOOD ENGINEERING, 2017, 204 : 18 - 26
  • [10] Effects of alternating magnetic field on freezing of minimally processed guava
    Panayampadan, Afthab Saeed
    Alam, Mohammed Shafiq
    Aslam, Raouf
    Gupta, Satish Kumar
    Sidhu, Gagandeep Kaur
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2022, 163