Exposure to electric and magnetic fields of electric power systems

被引:0
|
作者
Keikko, T [1 ]
Kuusiluoma, S [1 ]
Korpinen, L [1 ]
机构
[1] Tampere Univ Technol, Dept Elect Engn, Lab Elect Engn & Hlth, FIN-33101 Tampere, Finland
关键词
biological effects; electric and magnetic fields; harmonics; internal currents; international recommendations;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The magnetic fields from electric power system have been studied for several years now at Tampere University of Technology (TUT). Several studies have been carried out where exposure to electric and magnetic fields have been measured. Exposure recommendations in force are given by the Council of the European Union and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). The recommended current density value is 2 mA/m(2) for public exposure. For occupational exposure the recommended value is 10 mA/m(2) given by ICNIRP. The aim of this study was to calculate internal current induced by electric and magnetic fields of electric power system and to compare those results with the recommendations in force. The spheroidal calculation model was used. The internal currents calculated in this study were generally quite small.
引用
收藏
页码:2352 / 2356
页数:5
相关论文
共 50 条
  • [1] Comparison of electric and magnetic fields from electric power systems with exposure recommendations of the European Union
    Kuusiluoma, S
    Keikko, T
    Hovila, J
    Korpinen, L
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 843 - 848
  • [2] EXPOSURE ASSESSMENT FOR POWER FREQUENCY ELECTRIC AND MAGNETIC-FIELDS
    BRACKEN, TD
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1993, 54 (04): : 165 - 177
  • [3] Electric and magnetic fields at power frequencies
    Miller, Anthony B.
    Green, Lois M.
    CHRONIC DISEASES IN CANADA, 2010, 29 : 69 - 83
  • [4] EXPOSURE ASSESSMENT FOR ELECTRIC AND MAGNETIC-FIELDS
    PATTERSON, RM
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 1992, 2 (02): : 159 - 176
  • [5] Summary and evaluation of guidelines for occupational exposure to power frequency electric and magnetic fields
    Bailey, WH
    Su, SH
    Bracken, TD
    Kavet, R
    HEALTH PHYSICS, 1997, 73 (03): : 433 - 453
  • [7] Characteristics of Electric and Magnetic Fields in the Vicinity of a Quadruple Electric Power Line
    Salam, M. A.
    Ahmad, Hussein B.
    Ahmad, Noor Azlinda
    Sien, Ngai Jien
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2010, 11 (02):
  • [8] Electric and Magnetic Fields of Power Lines.
    Hanninen, Kenneth
    Valjus, Jorma
    Sahko, 1988, 61 (03): : 10 - 14
  • [9] Calculation of the Magnetic Fields of the Electric Power Line
    Patsiuk, V.
    Berzan, V.
    Rybacova, G.
    PROBLEMELE ENERGETICII REGIONALE, 2016, (03): : 15 - 26
  • [10] Exposure to 60-Hz magnetic and electric fields at a Canadian electric utility
    Deadman, JE
    Armstrong, BG
    Theriault, G