Liability and validity of the appropriateness evaluation protocol in Turkey

被引:12
|
作者
Kaya, S
Vural, G
Eroglu, K
Sain, G
Mersin, H
Karabeyoglu, M
Sezer, K
Türkkani, B
Restuccia, JD
机构
[1] Harvard Univ, Sch Publ Hlth, Takemi Program Int Hth, Boston, MA 02115 USA
[2] Hacettepe Univ, Sch Hlth Adm, Fac Med Hosp, TR-06100 Ankara, Turkey
[3] Hacettepe Univ, Sch Nursing, Fac Med Hosp, TR-06100 Ankara, Turkey
[4] Hacettepe Univ, Dept Infect Dis, Fac Med Hosp, TR-06100 Ankara, Turkey
[5] Oncol Hosp, Dept Gen Surg, Ankara, Turkey
[6] Numune Hosp, Gen Surg Dept, Ankara, Turkey
[7] Numune Hosp, Dept Internal Med, Ankara, Turkey
[8] Numune Hosp, Dept Gynecol & Obstet, Ankara, Turkey
[9] Boston Univ, Sch Management, Hlth Care Management Program, Boston, MA 02215 USA
[10] Boston Univ, Sch Management, Operat Management Dept, Boston, MA 02215 USA
关键词
Appropriateness Evaluation Protocol; reliability; Turkey; utilization review; validity;
D O I
10.1093/intqhc/12.4.325
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objective. To assess the inter-rater reliability between nurses and the convergent validity of the Appropriateness Evaluation Protocol (AEP) in the Turkish context. Methods. Two nurses applied the original AEP concurrently to a random subsample of 335 patient-days in internal medicine, general surgery, and gynaecology departments at a university hospital and a government teaching hospital, as a part of a larger study. Inter-rater reliability was tested by calculating overall agreement and specific agreements between nurse reviewers' AEP assessments. Validity was tested by comparing the assessments of the nurses based on the AEP with the implicit judgements of five expert physicians on a random subsample of 818 patient-days. Sensitivity, specificity, positive and negative predictive values of the AEP were calculated. Reliability and validity were also evaluated by the kappa statistic. Results. In the reliability test, there was a high level of agreement between the two independent raters applying the AEP appropriate agreement = 88.3 - 96.6%. In validity testing, the AEP had a sensitivity of 0.83-0.97, specificity of 0.62-0.80, and positive and negative predictive values of 0.84-0.88 and 0.73-0.95 respectively. Kappa coefficients in internal medicine and gynaecology indicated almost perfect agreement in reliability testing and moderate agreement in validity testing. In general surgery, the kappa coefficients showed substantial agreement in both tests. Conclusion. These results indicate that the AEP is a reliable and valid instrument to assess appropriateness of patient-days in Turkey.
引用
收藏
页码:325 / 329
页数:5
相关论文
共 50 条
  • [1] Validity of the appropriateness evaluation protocol
    Peiro, S
    Meneu, R
    Rosello, ML
    Portella, E
    CarbonellSanchis, R
    Fernandez, C
    Lazaro, G
    Llorens, MA
    MartinezMas, E
    Moreno, E
    Ruano, M
    Rincon, A
    Vila, M
    MEDICINA CLINICA, 1996, 107 (04): : 124 - 129
  • [2] Reliability and validity of the Appropriateness Evaluation Protocol in Turkey (vol 12, pg 325, 2000)
    Kaya, S
    Vural, G
    Eroglu, K
    Sain, G
    Mersin, H
    Karabeyoglu, M
    Sezer, K
    Türkkani, B
    Restuccia, JD
    INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2000, 12 (05) : 449 - 449
  • [3] Reliability and Validity of the Chinese Version Appropriateness Evaluation Protocol
    Liu, Wenwei
    Yuan, Suwei
    Wei, Fengqing
    Yang, Jing
    Zhang, Zhe
    Zhu, Changbin
    Ma, Jin
    PLOS ONE, 2015, 10 (08):
  • [4] The appropriateness evaluation protocol
    Sangha, O
    ZEITSCHRIFT FUR GERONTOLOGIE UND GERIATRIE, 2000, 33 : 43 - 43
  • [5] Reliability and validity of the French version of the first part of Appropriateness Evaluation Protocol (AEPf): criteria of appropriateness of hospital days
    Robain, M
    Lang, T
    Fontaine, A
    Logerot, H
    Monnet, E
    Six, P
    Huet, B
    REVUE D EPIDEMIOLOGIE ET DE SANTE PUBLIQUE, 1999, 47 (02): : 139 - 149
  • [6] A STUDY OF APPROPRIATENESS OF ACUTE GERIATRIC ADMISSIONS AND AN ASSESSMENT OF THE APPROPRIATENESS EVALUATION PROTOCOL
    TSANG, P
    SEVERS, MP
    JOURNAL OF THE ROYAL COLLEGE OF PHYSICIANS OF LONDON, 1995, 29 (04): : 311 - 314
  • [7] The use of Appropriateness Evaluation Protocol in otorhinolaryngology patients
    Neumann, A
    Schultz-Coulon, HJ
    HNO, 2001, 49 (01) : 12 - +
  • [8] Reliability study of the European appropriateness evaluation protocol
    Lorenzo, S
    Lang, T
    Pastor, R
    Tampieri, A
    Santos-Eggimann, B
    Smith, H
    Liberati, A
    Restuccia, J
    INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 1999, 11 (05) : 419 - 424
  • [9] Evaluation of the appropriateness of hospital care in internal medicine:: Reliability of a German adaptation of the "Appropriateness Evaluation Protocol".
    Schneeweiss, S
    Sangha, O
    Siebert, H
    Hebeisen, H
    Hübner, M
    Heinrich, R
    Wildner, M
    Witte, J
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2000, 125 (30) : 894 - 899
  • [10] Are really objective the criteria of Appropriateness Evaluation Protocol (AEP)?
    García, JLZ
    Caparrós, GC
    Martín-Escalante, MD
    MEDICINA CLINICA, 2002, 118 (04): : 158 - 158