A comparative study of contrast-enhanced ultrasound and contrast-enhanced CT for the detection and characterization of renal masses

被引:4
|
作者
Fang, Liang [1 ,4 ]
Bai, Kun [2 ]
Chen, Yue [1 ,4 ]
Zhan, Jia [1 ,4 ]
Zhang, Yinjia [1 ,4 ]
Qiu, Zhiying [1 ,4 ]
Chen, Lin [1 ,4 ]
Wang, Ling [3 ]
机构
[1] Fudan Univ, Huadong Hosp, Dept Ultrasound, 211 West Yanan Rd, Shanghai 200040, Peoples R China
[2] Fudan Univ, Jiading Cent Hosp, Dept Ultrasound, Shanghai, Peoples R China
[3] Fudan Univ, Dept Reprod Immunol, Obstet & Gynecol Hosp, Shanghai, Peoples R China
[4] Shanghai Key Lab Clin Geriatr Med, Shanghai, Peoples R China
关键词
Contrast enhanced ultrasound; renal cell carcinoma; contrast enhanced CT; CELL CARCINOMA; DIFFERENTIATION; ULTRASONOGRAPHY; SUBTYPES; ANGIOMYOLIPOMA; PSEUDOCAPSULE; FEATURES; CANCER;
D O I
10.5582/bst.2021.01026
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aims to compare the value of contrast-enhanced ultrasound (CEUS) and contrast-enhanced CT (CECT) in the differential diagnosis of benign and malignant renal masses. Included in this retrospective study were 143 renal masses in 141 patients using histopathological findings as the gold standard. A comparison was made of the two modalities in image characteristics for their accuracy in the differential diagnosis of renal masses. CEUS and CECT were both used for 39 masses in 37 patients, with 31 (79.5%) being malignant and 8 (20.5%) benign. The differences between the benign and malignant groups in perfusion intensity, perfusion uniformity and entry and exit of the contrast agent were not statistically significant (P > 0.05). However, CEUS could better display the circular perfusion of renal cell carcinoma than CECT (P < 0.05). CECT alone detected 109 masses in 107 patients, with 93 (85.3%) being malignant and 16 (14.7%) benign. CEUS detected 73 masses in 71 patients, with 56 (76.7%) being malignant and 17 (23.3%) benign. No statistically significant differences were observed between CEUS and CECT in the diagnosis of renal cell carcinoma (92.8% vs. 90.3%), with a specificity of 52.9% vs. 31.2%, an accuracy of 83.5% vs. 81.6%, and a positive predictive value of 86.7% vs. 88.4% or a negative predictive value of 69.2% vs. 35.7% (P > 0.05 for all). These results suggested both CEUS and CECT are highly valuable in the differential diagnosis of renal masses, and CEUS can be used as an important supplement for CECT in diagnosis of renal cancer.
引用
收藏
页码:24 / 32
页数:9
相关论文
共 50 条
  • [1] Contrast-enhanced Ultrasound of Renal Masses
    Bennett, Jack
    Peterson, Cynthia
    Barr, Richard G.
    APPLIED RADIOLOGY, 2020, 49 (06) : 10 - 16
  • [2] Renal Masses With Equivocal Enhancement at CT: Characterization With Contrast-Enhanced Ultrasound
    Bertolotto, Michele
    Cicero, Calogero
    Perrone, Rosaria
    Degrassi, Ferruccio
    Cacciato, Francesca
    Cova, Maria A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (05) : W557 - W565
  • [3] CONTRAST-ENHANCED ULTRASOUND FOR SMALL RENAL MASSES
    Oh, Tae Hoon
    Ahn, Seong Hoon
    Kwon, Whi An
    Lee, Jea Whan
    Han, Dong Youp
    Park, Seung Chul
    Jeong, Hee Jong
    Seo, Ill Young
    JOURNAL OF UROLOGY, 2014, 191 (04): : E109 - E110
  • [4] Evaluation of Renal Masses with Contrast-Enhanced Ultrasound
    S. Houtzager
    H. Wijkstra
    J. J. M. C. H. de la Rosette
    M. P. Laguna
    Current Urology Reports, 2013, 14 : 116 - 123
  • [5] Evaluation of Renal Masses with Contrast-Enhanced Ultrasound
    Houtzager, S.
    Wijkstra, H.
    de la Rosette, J. J. M. C. H.
    Laguna, M. P.
    CURRENT UROLOGY REPORTS, 2013, 14 (02) : 116 - 123
  • [6] Contrast-enhanced ultrasound for characterizing renal masses
    Bertolotto, Michele
    Bucci, Stefano
    Valentino, Massimo
    Curro, Francesca
    Sachs, Camilla
    Cova, Maria Assunta
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 41 - 48
  • [7] Characterization of Renal Masses with Harmonic and Subharmonic Contrast-Enhanced Ultrasound
    Eisenbrey, John R.
    Shaw, Colette M.
    Lyshchik, Andrej
    Machado, Priscilla
    Lallas, Costas D.
    Trabulsi, Edouard J.
    Merton, Daniel A.
    Fox, Traci B.
    Liu, Ji-Bin
    Brown, Daniel B.
    Forsberg, Flemming
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 193 - 196
  • [8] The characterization of small hypoattenuating renal masses on contrast-enhanced CT
    Patel, NS
    Yeh, BM
    Qayyum, A
    Breiman, RS
    Lu, Y
    Coakley, FV
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 5 - 5
  • [9] The characterization of small hypoattenuating renal masses on contrast-enhanced CT
    Patel, Neesha S.
    Poder, Liina
    Wang, Zhen J.
    Yeh, Benjamin M.
    Qayyum, Aliya
    Jin, Hua
    Coakley, Fergus V.
    CLINICAL IMAGING, 2009, 33 (04) : 295 - 300
  • [10] Contrast-enhanced ultrasound for differentiating benign from malignant solid small renal masses: comparison with contrast-enhanced CT
    Wei, Shu-Ping
    Xu, Chao-Li
    Zhang, Qing
    Zhang, Qi-Rui
    Zhao, Yan-E
    Huang, Peng-Fei
    Xie, Ying-Dong
    Zhou, Chang-Sheng
    Tian, Fu-Li
    Yang, Bin
    ABDOMINAL RADIOLOGY, 2017, 42 (08) : 2135 - 2145